The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
What's NewWhat's New
What's New
Support for HP 900GB 6G SAS 10K SFF (2.5-inch) Enterprise 3yr Warranty Hard Drive
QuickSpecs
HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)
Overview
DA - 13248 North America — Version 35 — May 19, 2011
Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 58 59

Indice de contenidos

Pagina 1 - QuickSpecs

The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellenceand 2U density for

Pagina 2

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori

Pagina 3

HP Insight ControlHP Insight ControlHP Insight ControlHP Insight Controlmanagement softwaremanagement softwaremanagement softwaremanagement softwareHP

Pagina 4

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Pagina 5

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Pagina 6

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Pagina 7

Four Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsNOTE:NOTE:

Pagina 8

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite supportEight Drive

Pagina 9

Twelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsNO

Pagina 10

P410/256 BBWC 25 SFFP410/256 BBWC 25 SFFP410/256 BBWC 25 SFFP410/256 BBWC 25 SFF750W PS Server750W PS Server750W PS Server750W PS Server590640-001Cach

Pagina 11

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte

Pagina 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryInteg

Pagina 13

S-BUY DL180G6 E5540S-BUY DL180G6 E5540S-BUY DL180G6 E5540S-BUY DL180G6 E55408GB 8LFF8GB 8LFF8GB 8LFF8GB 8LFF532078-005Processor(s)Processor(s)Processo

Pagina 14

S-BUY DL180G6 X5660S-BUY DL180G6 X5660S-BUY DL180G6 X5660S-BUY DL180G6 X566024GB 12LFF24GB 12LFF24GB 12LFF24GB 12LFF605664-005Processor(s)Processor(s)

Pagina 15

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Pagina 16

Step 2: Choose Required Options (only one of the following from each list unless otherwiseStep 2: Choose Required Options (only one of the following f

Pagina 17

HP MemoryHP MemoryHP MemoryHP MemoryRegistered RDIMMsRegistered RDIMMsRegistered RDIMMsRegistered RDIMMsHP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-13

Pagina 18

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesNOTE:NOTE:NOTE:NOTE: Many HP ProLiant Servers now offer new power options, includi

Pagina 19

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Pagina 20

HP DL180 G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) Processor Kit590605-B21HP DL180 G6 Intel® Xeon® L5520 (2.26GHz/4-core/8MB/60W) Processor Kit5

Pagina 21

HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LPMemory Kit627812-B21Unregistered with ECC UDIMMsUnregistered with ECC UDIMMsUn

Pagina 22

HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty HardDrive S-Buy507127-S21HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Ent

Pagina 23

Intel® Xeon® E5503 (2.0GHz/2-core/4MB/80W, DDR3-800) ProcessorNOTE:NOTE:NOTE:NOTE: Available through Configure To Order only. See Factory Integration

Pagina 24

SATA Hot Plug LFF (3.5-inch) Entry (ETY) DrivesSATA Hot Plug LFF (3.5-inch) Entry (ETY) DrivesSATA Hot Plug LFF (3.5-inch) Entry (ETY) DrivesSATA Hot

Pagina 25

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Pagina 26

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster Management UtilityHP Cluster Management Uti

Pagina 27

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option Kit488069-B21NOTE:NOTE:NOTE:NOTE: The TPM (Trust

Pagina 28

HP 512MB P-Series Battery Backed Write Cache UpgradeNOTE:NOTE:NOTE:NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411Controller

Pagina 29

HP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoverySoftwareSoftwareSoftwareSoftwareData Protector Express

Pagina 30

HP Disk BackupHP Disk BackupHP Disk BackupHP Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of StorageWorks D2D Backup Systems see:http://www.

Pagina 31

HP StorageWorks U320e SCSI Dual Channel Host Bus AdapterNOTE:NOTE:NOTE:NOTE: Recommended for MSL SCSI Tape Library connect.AH627AStorageWorks Converge

Pagina 32

HP Power DistributionHP Power DistributionHP Power DistributionHP Power DistributionUnitsUnitsUnitsUnitsMonitored PDUsMonitored PDUsMonitored PDUsMoni

Pagina 33

doors, you must allow 830 square inches (5,350 sq cm) of hole evenlydistributed from top to bottom to permit adequate airflow (equivalent to therequir

Pagina 34

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsSlot NumberSlot NumberSlot NumberSlot NumberBus SpeedBus SpeedBus SpeedBus SpeedBus Number

Pagina 35

HP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB-PS/2 MouseDC369AHP USB 04 Standard KeyboardDT528A#ABAHP Car

Pagina 36

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6HP ProLiant DL180 G6HP Pro

Pagina 37

DIMM Type ->Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Unbuffered with ECC DIMMsUnbuffered

Pagina 38

12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node) CPU1CPU1CPU1CPU1 CPU2CPU2CPU2

Pagina 39

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 16GB DIMM1D: emptyChnl 12A: 16GB DIMM2A: empty Ch

Pagina 40

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 4GB DIMM1D: 4GB DIMMChnl 12A: 4GB DIMM2A: 4GB DIMM

Pagina 41

HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7Memory Kit500666-B21HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered

Pagina 42

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Pagina 43

HP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC ControllerHP Smart Array Hot Plug Advance Pac

Pagina 44

HP Smart Array P410/512 MB BBWC ControllerHP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC

Pagina 45

(P/N: 516471-B21) is required to enable RAID 6, 6+0NOTE:NOTE:NOTE:NOTE: To achieve highest possible stated transfer rate please make sure the firmware

Pagina 46

HP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC ControllerUp to 14 with 12drive cage +Rear Drive Cage1-14HP Smart Array P212/256 MB

Pagina 47

External StorageExternal StorageExternal StorageExternal Storage QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionP

Pagina 48

Tape DrivesTape DrivesTape DrivesTape DrivesDAT 160DAT 320LTO-2 Ultrium 448LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840LTO-5 Ultrium 3000LTO-

Pagina 49

HP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DBackup Systems, iSCSIBackup Systems, iSCSIBackup Systems, iSCSIBackup Syst

Pagina 50

HP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply Kit

Pagina 51

HP 460W Common Slot Platinum Hot Plug Power Supply KitHP 460W Common Slot Platinum Hot Plug Power Supply KitHP 460W Common Slot Platinum Hot Plug Powe

Pagina 52

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in

Pagina 53

System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operatingNon-operatingNon-operatingNon-operating-30° to 60°C (

Pagina 54

HP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATA7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5

Pagina 55

Smart Array P410/410iSmart Array P410/410iSmart Array P410/410iSmart Array P410/410iControllerControllerControllerControllerDisk Drive and EnclosureDi

Pagina 56

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI V2.0 CompliantPCI 2.2 CompliantPXE Su

Pagina 57

System FansSystem FansSystem FansSystem Fans4 system fans ship standard; Non-hot plug, Non-redundantNOTE:NOTE:NOTE:NOTE: Redundant fan kit (P/N 516009

Pagina 58

agents, providers, and a SmartStart 'like' deployment CD called Easy Set-upwhich greatly simplifies server set-up. Additionally the DL100 an

Pagina 59

Array Configuration Utility (ACU) has been combined with ArrayDiagnostics Utility (ADU) to offer both configuration of arraycontrollers and storage de

Comentarios a estos manuales

Sin comentarios