HP 583108-421 Ficha de datos

Busca en linea o descarga Ficha de datos para Servidores HP 583108-421. HP ProLiant 583108-421 server Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Powered by latest AMD Opteron® 8, 12 and 16 core processors, the HP ProLiant DL585 G7 is positioned as the leading price
performance 4P multi-core rack mount server with the expansion capabilities to make it ideal for server virtualization, server
consolidation, multi-tiered enterprise application, and corporate infrastructure applications.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Quick Removal Access Panel
1.
Hot Plug Redundant Power supplies (2 or 4 ship depending
on the model)
2.
4 Hot Plug Redundant Fans Standard on all models
2.
Integrated Lights-Out 3 port
3.
Slimline Drive (DVD Drive optional)
3.
Mouse port
4.
Front Panel LED Display and Power Button
4.
Serial port
5.
Slide-out Systems Insight Display
5.
Gigabit NIC Ports
6.
Two front accessible USB 2.0 ports
6.
Gigabit NIC Ports
7.
One front video port
7.
Gigabit NIC Ports
8.
Quick release levers for fast server access
8.
Gigabit NIC Ports
9.
Front accessible Processor and memory drawer
9.
Video port
10.
Support for up to four AMD Opteron processors
10.
Keyboard port
11.
Support for up to eight hot plug Small Form-Factor (SFF)
SAS/ Serial ATA (SATA)/Solid State drives
11.
PCI-Express or PCI-X option (slots 1-6)
12.
Universal Tool-less "Snap In" Sliding Rail Solution
12.
PCI-Express slots (slots 7-11)
13.
Server Lifting Handles
13.
Two USB ports
14.
4U (7" Height) Rack Form Factor
14.
Service tool
15.
Up to eleven available PCI Express/PCI-X Internal
Expansion Slots
What's New
What's NewWhat's New
What's New
Support for new AMD Opteron 6200 series processor refresh
Support for HP 300GB 6G SAS Enterprise Hard Disk Drive
1TB max memory with support of new 16GB and 32 GB DDR3-1333 low-power memory RDIMMs
QuickSpecs
HP ProLiant DL585 Generation 7 (G7)
HP ProLiant DL585 Generation 7 (G7)HP ProLiant DL585 Generation 7 (G7)
HP ProLiant DL585 Generation 7 (G7)
Overview
DA - 13642 Worldwide — Version 28 — November 14, 2011
Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 55 56

Indice de contenidos

Pagina 1 - QuickSpecs

Powered by latest AMD Opteron® 8, 12 and 16 core processors, the HP ProLiant DL585 G7 is positioned as the leading priceperformance 4P multi-core rac

Pagina 2

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Pagina 3

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Pagina 4

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Pagina 5

Standard CareStandard CareStandard CareStandard CareStandard Care Package: Package that maintains high level of server availabilityStandard Care Packa

Pagina 6

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Pagina 7

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite supportwith next business day response.HP ProLiant

Pagina 8

P410i/1GB FBWC 8 SFFP410i/1GB FBWC 8 SFFP410i/1GB FBWC 8 SFFP410i/1GB FBWC 8 SFF1200W RPS Perf IC Svr1200W RPS Perf IC Svr1200W RPS Perf IC Svr1200W R

Pagina 9

Optical DriveOptical DriveOptical DriveOptical DriveNone ship standardPower SupplyPower SupplyPower SupplyPower SupplyFour 1200W Power Supplies standa

Pagina 10

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite supportwith next business day response.Country Code

Pagina 11

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Pagina 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Pagina 13

HP DL585 G7 AMD Opteron™ 6174 (2.2GHz/12-core/12MB/115W) FIO 2-processor Kit601353-L21HP DL585 G7 AMD Opteron™ 6172 (2.1GHz/12-core/12MB/115W) FIO 2-p

Pagina 14

Step 3: Choose Additional Factory Integratable Options (only one of the following from eachStep 3: Choose Additional Factory Integratable Options (onl

Pagina 15

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Pagina 16

HP DL585 G7 AMD Opteron™ 6166HE (1.8GHz/12-core/12MB/85W) 2-processorKit633971-B21HP DL585 G7 AMD Opteron™ 6164HE (1.7GHz/12-core/12MB/85W) 2-processo

Pagina 17

firmware, and the server backplane) should operate at the same data transfer rate orthe system bandwidth will be negotiated down to an acceptable leve

Pagina 18

6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performan

Pagina 19

HP InfiniBandHP InfiniBandHP InfiniBandHP InfiniBandHP InfiniBand 4X DDR PCI-E 0 Memory Dual Port HCA483513-B21QLogic InfiniBand 4X QDR PCI-E G2 Dual

Pagina 20

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Pagina 21

NOTE:NOTE:NOTE:NOTE: This license allows 1 server to be deployed and managed via HP iLOAdvanced. Customer will receive a printed license entitlement c

Pagina 22

NOTE:NOTE:NOTE:NOTE: For additional license kits please see the QuickSpecs at:http://h18004.www1.hp.com/products/quickspecs/13485_div/13485_div.html H

Pagina 23

Memory ProtectionMemory ProtectionMemory ProtectionMemory ProtectionAdvanced ECC capabilitiesOnline Spare MemoryMemoryMemoryMemoryMemoryTypePC3-10600R

Pagina 24

Smart Array P410 ControllerSmart Array P410 ControllerSmart Array P410 ControllerSmart Array P410 Controller HP Smart Array P410/256 2-ports Int PCIe

Pagina 25

HP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus AdapterNOTE:NOTE:NOTE:NOTE: Recommended HBA for SCSI tape drive connect.412911-B21NOTE:NOTE:N

Pagina 26

HP RDX Removable Disk Backup Systems USBHP RDX Removable Disk Backup Systems USBHP RDX Removable Disk Backup Systems USBHP RDX Removable Disk Backup S

Pagina 27

HP Disk Storage SystemsHP Disk Storage SystemsHP Disk Storage SystemsHP Disk Storage SystemsMSA SAN Storage ArraysMSA SAN Storage ArraysMSA SAN Storag

Pagina 28

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for additional information:http://h18000.www1.hp.com/products/quickspecs/14110_div/14110_div.html(World

Pagina 29

HP Intelligent PowerHP Intelligent PowerHP Intelligent PowerHP Intelligent PowerDistribution Units (iPDU)Distribution Units (iPDU)Distribution Units (

Pagina 30

blanking panels results in improper cooling that can lead to thermal damage.NOTE:NOTE:NOTE:NOTE: Quick deploy rail system provides tool-free support f

Pagina 31

HP TFT7600 G2 KVM Console Rackmount Keyboard US TAA MonitorAZ885ANOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and addit

Pagina 32

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/13

Pagina 33

NOTE:NOTE:NOTE:NOTE: Standard memory configurations listed do not apply to "Factory Integrated Models."HP ProLiant DL585 G7 ModelsHP ProLian

Pagina 34

4PCI-Expressx8x16Full Length/FullHeight 5PCI-Expressx8x16Full Length/FullHeight 6PCI-Expressx16 x16Full Length/FullHeight 7PCI-Expressx8x16Full Le

Pagina 35

Processormemory socket1111 2222 3333 4444 5555 6666Rank support permemory socketSR/DRSR/DR/QRSR/DR SR/DRSR/DR/QRSR/DRPopulation orderAAAAIIIIEEEECCCCK

Pagina 36

Memory modules perchannelQRSR or DRSR or DRSR or DRSR or DRMemory modulenative speedMemory bus speed(standard-voltagememory moduleMemory bus speed(low

Pagina 37

Memory Installation ExampleMemory Installation ExampleMemory Installation ExampleMemory Installation ExampleThese memory installation example shows th

Pagina 38

HP DL585 G7 CPU Memory Secondary Upgrade OptionNOTE:NOTE:NOTE:NOTE: Adds processor sockets 3 and 4.590489-B21QuickSpecsHP ProLiant DL585 Generation 7

Pagina 39

1-8Eight SFF SAS hot plug hard drive bays Drive SupportDrive SupportDrive SupportDrive Support QuantityQuantityQuantityQuantitySupportedSupportedSuppo

Pagina 40

HP Smart Array P812/512 BBWC ControllerSAS Hot Plug SFF (2.5-inch) Midline (MDL) DrivesSAS Hot Plug SFF (2.5-inch) Midline (MDL) DrivesSAS Hot Plug SF

Pagina 41

6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performan

Pagina 42

D2700 Disk EnclosureUp to 2ExternalHP Smart Array P211/256 MB ControllerUp to 4ExternalHP Smart Array P411/256 MB ControllerHP Smart Array P411/512 MB

Pagina 43

DAT 320LTO-2 Ultrium 448LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840LTO-5 Ultrium 3000LTO-5 Ultrium 32801U Rack-Mount Kit3U Rack-Mount KitNOT

Pagina 44

HP D2D Backup Systems,HP D2D Backup Systems,HP D2D Backup Systems,HP D2D Backup Systems,Fibre ChannelFibre ChannelFibre ChannelFibre ChannelD2D

Pagina 45

Storage ControllerStorage ControllerStorage ControllerStorage ControllerOne of the followingdepending on ModelPerformance ModelsHP Smart Array P410i/1

Pagina 46

HP 1200W Common Slot Silver Hot Plug Power Supply KitHP 1200W Common Slot Silver Hot Plug Power Supply KitHP 1200W Common Slot Silver Hot Plug Power S

Pagina 47

NOTE:NOTE:NOTE:NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url:www.hp.com/go/proliant-e

Pagina 48

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)6.94" x 19.0" x 27.55" (17.

Pagina 49

AltitudeAltitudeAltitudeAltitudeOperating3050 m (10,000 ft). This value may be limitedby the type and number of options installed.Maximum allowable al

Pagina 50

VMware ESX 3.5.0Client System SupportClient System SupportClient System SupportClient System SupportMicrosoft Windows 7Microsoft Windows XP Profession

Pagina 51

option upgrades512 MB BBWC/FBWC and Smart Array Advanced Pack License keyoption upgrades1G FBWC and Smart Array Advanced Pack License key optionupgrad

Pagina 52

© Copyright 2011 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Pagina 53

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI 2.0. CompliantPCI 2.0 CompliantPXE Su

Pagina 54

solution on all ProLiant servers supported by Insight Foundation version8.70. It evolves beyond separate installation of HP PSPs and the HP SmartUpdat

Pagina 55

Dynamics for ProLiant, helping customers unleash the value of the ProLiantplatform and deliver the highest possible quality of IT service. For moreinf

Pagina 56

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Comentarios a estos manuales

Sin comentarios