Hp NetRAID 1Si Controller Manual de usuario Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 161
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
Chapter 2 HP NetRAID Assistant
27
Define your physical arrays.
Assign dedicated hot spares, if desired.
Define logical drives.
Preview configuration and save it to NVRAM (non-volatile memory).
Save the configuration to a binary file.
Print the configuration.
Configure any other adapters.
Initialize logical drives.
Exit HP NetRAID Assistant.
Select the Adapter to Configure
Look in the Adapter box to see if the adapter you wish to configure is displayed. If
not, select it from the pull-down list.
Clear Configuration (if necessary)
If you want to set up a brand-new configuration, you should clear the existing
configuration.
To clear the existing configuration:
1. Select the Configuration menu.
2. Choose Clear Configuration.
3. Click OK.
Check Rebuild Rate
During a rebuild, the contents of a complete physical drive is rewritten. Normal
operations can go on during a rebuild, but performance may be degraded. The
Rebuild Rate controls the rate at which a rebuild is done. A high Rebuild Rate
(over 50%) speeds up the rebuild, but slows system performance. A low Rebuild
Rate (under 50%) slows the rebuild process, but speeds up system performance.
The default setting for the Rebuild Rate is 50%.
To check the Rebuild Rate from the HP NetRAID Assistant window:
1. Select the adapter for which you want to check the Rebuild Rate.
2. Select Rebuild Rate from the Adapter menu.
Vista de pagina 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 160 161

Comentarios a estos manuales

Sin comentarios