Hp Smart Array P600-Controller Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
Installing the controller hardware 11
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
5. If the added drives are not hot-pluggable, power up the system.
Connecting external storage
1. Power down the server.
2. Connect an external SAS cable to the external port of the controller.
NOTE: You do not have to disconnect any internal drives on shared internal port 1I because
the controller preferentially discovers devices attached to port 1E. However, drives on the
shared internal port are unavailable until you disconnect the external storage device.
3. Tighten the lock screws on the cable connector.
4. Attach the other end of the cable to the SAS input connector of the external storage enclosure.
IMPORTANT: Drives that are to be used in the same array must be of the same type, either all
SAS or all SATA. (Parallel SCSI drives cannot be used with this controller.)
5. Tighten the lock screws on the cable connector.
6. Power up the enclosure.
7. Power up the server.
SAS cable part numbers
NOTE: If you require additional cables, order them by the option kit number.
SAS cable type Cable length Option kit number Cable assembly number
External cable 1.0 m (3.3 ft)
2.0 m (6.6 ft)
4.0 m (13 ft)
6.0 m (20 ft)
389665-B21
389668-B21
389671-B21
389674-B21
361317-001
361317-002
361317-004
361317-006
Internal wide cable depends on the
server
refer to the server
documentation
361316-00x
Vista de pagina 10