HP ProLiant ML310 Generation 4 Server User Guide November 2006 (Second Edition) Part Number 419351-002
Component identification 10 Item Description Status 1 NIC link LED On = Link Off = No link 2 NIC activity LED Flashing = Activity Off = No a
Component identification 11 Item Description 20 PCI expansion slot 3 (PCI-X, 64-bit/100-MHz) 21 PCI expansion slot 4 (PCI Express x4**) 22 System
Component identification 12 System board LEDs Item LED description Status 1 PPM error Amber = PPM has failed Off = Normal 2 DIMM 4 failure
Component identification 13 Item LED description Status 11 Single bit error Amber = Single bit error limit has been exceeded Off = Normal 12 Syst
Component identification 14 SAS and SATA device numbers Hot-plug SATA or SAS hard drive LEDs Item LED description Status 1 Fault/UID status
Component identification 15 The hard drive activity LED will not illuminate if using SATA drives connected to the embedded storage device. In this c
Operations 16 Operations In this section Power up the server...
Operations 17 Unlock the tower bezel The removable bezel must be unlocked and opened before accessing the hard drive cage and media bays. It must be
Operations 18 4. Power up the server (on page 16).
Setup 19 Setup In this section Optional installation services ...
© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties
Setup 20 Rack planning resources The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more informa
Setup 21 Temperature requirements To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, cli
Setup 22 Warnings and cautions WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are
Setup 23 The contents of the server shipping carton include: • Server • Power cord • Keyboard and mouse (not included in all configurations) • Ha
Setup 24 Item Description 6 USB connectors (2) 7 RJ-45 Ethernet connector 8 RJ-45 connector (iLO 2) 9 Parallel connector 2. Connect the power co
Hardware options installation 25 Hardware options installation In this section Introduction ...
Hardware options installation 26 The following table lists some, but not all, possible configurations. For best performance, HP recommends dual-chann
Hardware options installation 27 Hot-plug SATA and hot-plug SAS hard drives can be used interchangeably when a SAS controller is installed. Before in
Hardware options installation 28 4. Install the hard drive. 5. Determine the status of the hard drive from the hot-plug SAS hard drive LED combinat
Hardware options installation 29 7. Install the access panel (on page 17). 8. Install the bezel ("Unlock the tower bezel" on page 17). 9.
Contents 3 Contents Component identification...
Hardware options installation 30 8. Remove the applicable bezel blanks from the bezel. 9. Install the access panel (on page 17). 10. Install the be
Hardware options installation 31 5. Use a screwdriver to disengage the two wire supports inside the half-height drive bays. 6. Install the tape dri
Hardware options installation 32 7. Install the retaining screw. IMPORTANT: When installing a SCSI tape drive, an optional SCSI HBA controller is
Hardware options installation 33 2. Remove the bezel ("Unlock the tower bezel" on page 17). 3. Remove the access panel (on page 17). 4. R
Hardware options installation 34 Expansion boards The server supports PCI, PCI-X, and PCI Express expansion boards. Slot Expansion card type Conn
Hardware options installation 35 5. Install the expansion board, and press firmly down to seat the board in the connector. 6. Connect any required
Cabling 36 Cabling In this section SATA cabling ...
Cabling 37 SAS cabling NOTE: The hard drive fan cage is removed for clarity. Item Description 1 Power cable 2 SAS cable
Configuration and utilities 38 Configuration and utilities In this section Configuration tools...
Configuration and utilities 39 Using SmartStart technology, the Scripting Toolkit provides a flexible way to create standard server configuration sc
Contents 4 Cabling ...
Configuration and utilities 40 The auto-configuration process automatically runs when you boot the server for the first time. During the power-up se
Configuration and utilities 41 For optimum performance, the minimum display settings are 800 × 600 resolution and 256 colors. Servers running Micros
Configuration and utilities 42 Configuring the software SATA RAID feature CAUTION: Back up any data stored on the hard drives before proceeding.
Configuration and utilities 43 For more information on Software SATA RAID, see the HP Storage Manager HostRAID User Guide located on the Documentati
Configuration and utilities 44 Management tools Automatic Server Recovery ASR is a feature that causes the system to restart when a catastrophic ope
Configuration and utilities 45 • Automatically checks for hardware, firmware, and operating system dependencies, and installs only the correct ROM u
Configuration and utilities 46 • DOS • Operating environments which do not provide native USB support For more information on ProLiant USB support
Configuration and utilities 47 Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The IML timesta
Configuration and utilities 48 If you do not use the SmartStart CD to install an operating system, drivers for some of the new hardware are required
Battery replacement 49 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the bat
Contents 5 POST error messages and beep codes...
Troubleshooting 50 Troubleshooting In this section Troubleshooting resources ...
Troubleshooting 51 Important safety information Before servicing this product, read the Important Safety Information document provided with the se
Troubleshooting 52 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling feet are extended to t
Troubleshooting 53 Prepare the server for diagnosis 1. Be sure the server is in the proper operating environment with adequate power, air conditioni
Troubleshooting 54 Troubleshooting flowcharts To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this se
Troubleshooting 55 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of
Troubleshooting 56 Item Refer to 4 The most recent version of a particular server or option firmware is available on the following websites: • HP Su
Troubleshooting 57 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. • The ex
Troubleshooting 58 • The internal health LED is red or amber. NOTE: For the location of server LEDs and information on their statuses, refer to th
Troubleshooting 59
Component identification 6 Component identification In this section Front panel components ...
Troubleshooting 60 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system attemp
Troubleshooting 61 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Sma
Troubleshooting 62 Item Refer to 1 HP ROM-Based Setup Utility User Guide (http://www.hp.com/servers/smartstart) 2 "POST problems flowchart
Troubleshooting 63 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents (on pag
Troubleshooting 64 Possible causes: • Improperly seated or faulty internal or external component • Unsupported component installed • Redundancy fa
Troubleshooting 65 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in the
Regulatory compliance notices 66 Regulatory compliance notices In this section Regulatory compliance identification numbers ...
Regulatory compliance notices 67 Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device,
Regulatory compliance notices 68 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that a
Regulatory compliance notices 69 Disposal of waste equipment by users in private households in the European Union This symbol on the product or on
Component identification 7 Front panel LEDs and buttons Item Description Status 1 CD-ROM drive ejector button — 2 Power On/Standby button — 3
Regulatory compliance notices 70 Korean notice Class A equipment Class B equipment Laser compliance This product may be provided with an optical
Regulatory compliance notices 71 • Do not attempt to recharge the battery. • Do not expose the battery to temperatures higher than 60°C (140°F).
Electrostatic discharge 72 Electrostatic discharge In this section Preventing electrostatic discharge...
Specifications 73 Specifications In this section Environmental specifications ...
Specifications 74 Specification Value Rated steady-state power 3.3 V/5 V 110 W 12 V CPU 300W Maximum peak power 410 W (non-redundant non-hot-plug) 4
Technical support 75 Technical support In this section Related documents ...
Technical support 76 Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-h
Technical support 77 assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sost
Technical support 78 stellen. Im Falle von Customer Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den Kuri
Technical support 79 • Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, w
Component identification 8 Rear panel components NOTE: The server may look different from that shown. Item Description 1 Power supply connec
Technical support 80 Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços
Technical support 81
Technical support 82
Acronyms and abbreviations 83 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery DDR dou
Acronyms and abbreviations 84 LDAP Lightweight Directory Access Protocol MPS multi-processor specification NEMA National Electrical Manufacturers
Acronyms and abbreviations 85 RBSU ROM-Based Setup Utility RDP Rapid Deployment Pack SAS serial attached SCSI SATA serial ATA SDRAM synchronous
Index 86 A AC power supply 9 access panel 17 ACU (Array Configuration Utility) 40 additional information 75 ADU (Array Diagnostic Utility)
Index 87 H hard drive LEDs 14 hard drives 26 hardware options 25 hardware options installation 23, 25 health driver 44 help resources 75
Index 88 problem diagnosis 50 processor failure LEDs 11 ProLiant Support Pack (PSP) 48 PSPs, overview 48 R rack installation 19 rack resour
Component identification 9 Rear panel LEDs • Model with a redundant hot-plug power supply Item Description Status 1 NIC link LED On = Link O
Comentarios a estos manuales