HP 5300A Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 19
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
the utility is “hung” since no indications of what is actually happening are
present.
To check if the utility is still in startup or shutdown mode, you can put your
cursor in the bar at the top of your window. If the utility is still active, then the
cursor will change to an hour glass. This problem will be corrected in a future
release of the ACU-XE utility.
With cpqim310 installed, if you try to resize the windows between the disks
(middle pane) and the detailed info (right pane), the data goes away and both
panes turn dark brown/grey. A Netscape reload brings the data back. This
issue will be fixed in a future release of Netscape for the Tru64 UNIX.
Critical errors on the Smart Array 5300A controllers are accompanied by red
status messages within the Array Configuration Utility. The last statement in
each of these messages, "For more information, run the Array Diagnostics
Utility.", should be disregarded. Please use Compaq Analyze to obtain further
information about the reported errors.
When a condition occurs, such as a hardware fault, there may be data that
needs to be flushed from cache.To perform the actual cache flush, run the
BIOS from the SRM console on the affected controller.
Firmware Issues and Restrictions
The maximum possible number of logical drives that can be configured on a
Smart Array 5300A controller is thirty two.
Logical volume capacity extension is not supported.
The maximum logical volume size supported by the firmware is 2 Terabytes.
If a Hot Spare has replaced a failed physical drive within a redundant array,
the ACU-XE may show a logical volume having another volume below with
"???" as the spare capacity. Replacing the failed drive will cause the array to
return to the original configuration.
In the event of a SCSI bus failure, all logical devices on this bus might become
failed. There is a way these devices can be made available to the user (data
integrity cannot be guaranteed, however). You have to shutdown your Alpha
Server and run BIOS on the controller housing these devices, i.e:
>>run bios pya0
Release Notes – Smart Array 5300A Backplane RAID Controllers 13
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19

Comentarios a estos manuales

Sin comentarios

Philips 017266693 manuals

Owner’s manuals and user’s guides for Outdoor lighting Philips 017266693.
We providing 1 pdf manuals Philips 017266693 for download free by document types: Datasheet






More products and manuals for Outdoor lighting Philips

Models Document Type
14653046 Datasheet   Philips 01465/30/46, 2 pages
170864746 Datasheet   Philips Wall light 17086/47/46, 2 pages
170144786 Datasheet   Philips Wall light 17014/47/86, 2 pages
320103146 Datasheet   Philips Wall light 32010/31/46, 2 pages
168068776 Datasheet   Philips Wall light 16806/87/76, 2 pages
171308746 Datasheet   Philips Wall light 17130/87/46, 2 pages
168094776 Datasheet   Philips Wall light 16809/47/76, 2 pages
171734746 Datasheet   Philips Wall light 17173/47/46, 2 pages
017266631 Datasheet   Philips 017266631, 2 pages
171733046 Datasheet   Philips Wall light 17173/30/46, 2 pages
171059346 Datasheet   Philips Wall light 17105/93/46, 2 pages
171309346 Datasheet   Philips Wall light 17130/93/46, 2 pages
170149386 Datasheet   Philips Wall light 17014/93/86, 2 pages
170143186 Datasheet   Philips Wall light 17014/31/86, 2 pages
17264693 Datasheet   Philips 01726/46/93, 2 pages
171504716 Datasheet   Philips myGarden Wall light 17150/47/16, 2 pages
171058746 Datasheet   Philips Wall light 17105/87/46, 2 pages
016520616 Datasheet   Philips myGarden Wall light 01652/06/16, 2 pages
320109346 Datasheet   Philips Wall light 32010/93/46, 2 pages
163209316 Datasheet   Philips Ledino Wall light 16320/93/16, 2 pages