RAID 0 block-level striping across multiple RAID 6 arrays with dual distributed parity. With
the inclusion of dual parity, RAID 60 will tolerate the failure of two disks in each spanned
array without loss of data. Requires P711m.
Advanced Data Guarding (RAID 6):. It allocates two sets of parity data across drives and
allows simultaneous write operations. This level of fault tolerance can withstand two
simultaneous drive failures without downtime or data loss.
Distributed Data Guarding (RAID 5): This allocates parity data across multiple drives and
allows simultaneous write operations. It is recommended for up to 14 hard drives.
Receive pre-failure alerts with HP SIM. When drives installed in an MDS600 are used in
conjunction with the Smart Array Controller and Systems Insight Manager, the Smart Array
firmware in HP hard drives enables extensive fault prediction capabilities. If potential problems
develop in one of the drives, the Smart Array Controller, Systems Insight Manager and/or Smart
hard disk drive will send a pre-failure alert so you can have the drive replaced, before it fails,
under warranty.