HP Modular Smart Array 500 Starter Kit Guía de usuario Página 175: See also • set system

/ 186
Tabla de contenidos
HP StorageWorks 2300 Modular Smart Array CLI reference guide
175

verify vdisk

Description
Verifies whether vdisk redundancy data is consistent with its user data. For RAID 3, 5, 6, and 50,
verify checks all parity blocks to find data-parity mismatches. For RAID 1 and 10, verify compares
the primary and secondary disks to find data inconsistencies.
Verification can last over an hour, depending on vdisk size, utility priority, and amount of I/O
activity. When verification is complete, the number of inconsistencies found is reported with event
code 21 (
Vdisk verification complete
) in the event log. Such inconsistencies can indicate
that a disk in the vdisk is going bad. You can use a vdisk while it is being verified.
Syntax
verify vdisk
vdisks
Parameters
vdisks
Name or serial number of the vdisks to verify. For syntax, see
Command syntax
.
Example
Verify vdisk
VD1
:
# verify vdisk VD1
Info: Verify started on vdisk VD1
Success: Command completed successfully
See also
•
abort verify
•
show vdisks

Archivo PDF · ·

Imprimir

Imprimir documento

Compartiendo

Preguntas sobre HP Modular Smart Array 500 Starter Kit

Todavía no hay preguntas sobre este manual. Haga la primera.

Hacer una pregunta

Respondemos con el manual e indicamos la página. La pregunta se publica en el sitio después de revisarla.

Todas las preguntas y respuestas ›

Productos y manuales relacionados para Arrays de discos HP Modular Smart Array 500 Starter Kit