system set description
Description of Command Function
Defines the string used to label and identify the StoreOnce appliance. This label is part of the
replication process when the source or target appliance needs to be identified.
Command Syntax
system set description <appliance-name>
Command Authority
Administrator
Command Object Requirements
Not applicable – no objects exist within this command.
Command Parameter Requirements
appliance-name – a character string must appear after config set description in the
command entry. This string may contain the upper case letters, lower case letters, numbers, the
dash “-“ and the underscore “_”. The string must be a maximum of 32 characters.
Requirements for Command Execution
The command entry must conform to the command syntax.
Successful Command Output
Upon successful completion of the command, the following is displayed:
The StoreOnce appliance description is APPLIANCE-NAME, where APPLIANCE-NAME
is the string labeling the StoreOnce appliance.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this
section.
Example
# system set description Primary-D2D
The D2D appliance description is Primary-D2D
system set description 121