6
HP 5900 Switch Series
Specifications
HP 5900AF-48XG-4QSFP+ Switch (JC772A) HP 5900AF-48G-4XG-2QSFP+ Switch (JG510A)
Ports
48 fixed 1000/10000 SFP+ ports
4 QSFP+ 40-GbE ports
1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
48 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type
100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or
full; 1000BASE-T: full only
4 fixed 1000/10000 SFP+ ports
2 QSFP+ 40-GbE ports
1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
Power supplies
2 power supply slots
1 minimum power supply required (ordered separately)
2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
The customer must order fan trays, as fan trays are not included with the switch. This
system requires two same-direction airflow fan trays to function properly. The system
should not be operated with only one fan tray for more than 24 hours. The system
should not be operated without a fan tray for more than two minutes. The system
should not be operated outside of the temperature range of 32°F (0°C) to 113°F (45°C).
Failure to comply with these operating requirements may void the product warranty.
2 fan tray slots
The customer must order fan trays, as fan trays are not included with the switch. This
system requires two same-direction airflow fan trays to function properly. The system
should not be operated with only one fan tray for more than 24 hours. The system
should not be operated without a fan tray for more than two minutes. The system
should not be operated outside of the temperature range of 32°F (0°C) to 113°F (45°C).
Failure to comply with these operating requirements may void the product warranty.
Physical characteristics
17.32(w) x 25.98(d) x 1.72(h) in (43.99 x 65.99 x 4.37 cm) 17.32(w) x 18.11(d) x 1.72(h) in (43.99 x 46.0 x 4.37 cm) (1U height)
Weight
28.66 lb (13 kg), Fully loaded 28.66 lb (13 kg), Fully loaded
Memory and processor
512 MB flash, 2 GB SDRAM; packet buffer size: 9 MB 512 MB flash, 2 GB SDRAM; packet buffer size: 9 MB
Performance
10 Gbps Latency
< 1.5 µs (64-byte packets) < 1.5 µs (64-byte packets)
Throughput
952 million pps 250 million pps (64-byte packets)
Routing/Switching capacity
1280 Gbps 336 Gbps
Routing table size
16000 entries (IPv4), 8000 entries (IPv6) 16000 entries (IPv4), 8000 entries (IPv6)
MAC address table size
128000 entries 128000 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C) 32°F to 113°F (0°C to 45°C)
Operating relative humidity
10% to 90%, noncondensing 10% to 90%, noncondensing
Acoustic
Low-speed fan: 65.7 dB, High-speed fan: 70.6 dB Low-speed fan: 65.7 dB, High-speed fan: 70.6 dB
Electrical characteristics
Frequency
50/60 Hz 50/60 Hz
Maximum heat dissipation
887 BTU/hr (935.79 kJ/hr) 887 BTU/hr (935.79 kJ/hr)
Voltage
100-240 VAC 100-240 VAC
DC voltage
-36 to -72 VDC -36 to -72 VDC
Maximum power rating
260 W 260 W
Idle power
200 W 200 W
Notes
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical
maximum numbers provided for planning the infrastructure with fully loaded PoE (if
equipped), 100% traffic, all ports plugged in, and all modules populated.
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical
maximum numbers provided for planning the infrastructure with fully loaded PoE (if
equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser
Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN
60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser
Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN
60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22
Class A; EN 61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15) Class A
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22
Class A; EN 61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3 ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003 EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC 61000-4-2 EN 61000-4-2; IEC 61000-4-2
Radiated
EN 61000-4-3; IEC 61000-4-3 EN 61000-4-3; IEC 61000-4-3