HP ProDesk 490 G1 Especificaciones rápidas Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
QuickSpecs
HP ProDesk 490 G1 Microtower Business PC
Technical Specifications Power
c04123126 14695 Worldwide Version 9 January 21, 2015
Page 51
Temperature Range
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: 22° to 140° F(30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum
Altitude (unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
Power Supply
Standard Efficiency
300W active PFC
(230 VAC input only)
High Efficiency*
80 PLUS Bronze
300W active PFC
82/85/82% efficient at 20/50/100% load (115V)
82/85/82% efficient at 20/50/100% load (230V)
Operating Voltage Range
90 - 264 VAC
Rated Voltage Range
200 - 240 VAC (300W active PFC)
100 - 240 VAC
Rated Line Frequency
50/60 Hz
Operating Line Frequency
47 63 Hz
Rated Input Current
4A
Rated Input Current with Energy Efficient* Power Supply
4A
Current Leakage
(NFPA 99: 2102)
Less than 500 microamps of leakage current at
120 Vac with the ground wire disconnected, as
required for Non-patient Electrical Appliances
and Equipment used in a patient care facility or
that contact patients in normal use. Per section
10.3.5.1.
Less than 100 microamps of leakage current at
120 Vac with the ground wire intact with normal
polarity, as required for Non-patient Electrical
Vista de pagina 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 61 62

Comentarios a estos manuales