QuickSpecs
HP ProLiant ML150 Generation9 (Gen9)
Technical Specifications
c04447841 DA 15090 North America Version 1 December 1, 2014
Page 31
System Unit
Tower Dimensions
17.03(H) x 7.87(W) x 24.41(D) in (43.26 x 20 x 62 cm)
Tower Weight
Minimum:
37.26lb (16.9kg)
Maximum:
61.73lb (28kg)
Input
Requirements
(for Standard 460W
PSU, see power
specifications tables
for detail on 460W,
750W and 1200W
power supplies)
Range Line Voltage
Rated Input Current
100 to 240 VAC
For 550W Power Supply:6.7 A (at 100 VAC)3.3 A (at 100 VAC)
Rated Input
Frequency
47 to 63 Hz
Rated Input Power
For 550 W Power Supply:< 670 W (at 100 VAC),< 660 W (at 200 VAC),
BTU Rating
Maximum
For 550 W Power Supply: 2201 BTU/hr (at 100 VAC),2153 BTU/hr (at
200 VAC)
Power
Specifications
To review typical system power ratings use the Power Advisor which is available via the
online tool located at URL: www.hp.com/go/proliant-energy-efficient or
www.hp.com/go/hppoweradvisor - Click on the system of interest. Example: ML150 Gen9-
Follow the instructions of the next screens.
Power Supply
Output
Rated Steady-State
Power
For 550 W Power Supply:550 W (at 100 VAC),550 W (at 200 VAC),
Maximum Peak
Power
For 550 W Power Supply:550 W (at 100 VAC),550 W (at 200 VAC),
System Inlet
Temperature
Standard Operating
Support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of
1.0°Cper every 304.8 m (1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 20°C/hr (36°F/hr). The upper limit and rate
of change may be limited by the type and number of options installed.
System performance during standard operating support may be
reduced if operating with a fan fault or above 30°C (86°F).
Extended Ambient
Operating Support
For approved hardware configurations, the supported system inlet
range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C (95° to
104°F) at sea level with an altitude derating of 1.0°C per every 175 m
(1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050
m (10,000 ft). The approved hardware configurations for this system
are listed at the URL: http://www.hp.com/servers/ashrae
For approved hardware configurations, the supported system inlet
range is extended to be: 40° to 45°C (104° to 113°F) at sea level with an
altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft)
above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft). The
approved hardware configurations for this system are listed at the
URL: http://www.hp.com/servers/ashrae
System performance may be reduced if operating in the extended
ambient operating range or with a fan fault.
NOTE: Supports A3 extended ambient, A4 extended ambience will be
available in early 2015.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is
20°C/hr(36°F/hr).
Relative Humidity
Operating
Minimum to be the higher (more moisture) of -12°C (10.4°F) dew point
or 8% relative humidity. Maximum to be the lower (less moisture)
of24°C (75.2°F) dew point or 90% relative humidity.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb
temperature, non-condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited by the type and number
of options installed. Maximum allowable altitude change rate is
457m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is
457m/min (1500 ft/min).