HP ProLiant Smart Array E200 Especificaciones Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 65
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
Removal and replacement procedures 26
Hard drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade
or the enclosure unless all hard drive and device bays are populated with either a component
or a blank.
Remove the component as indicated.
To replace the blank, slide the blank into the bay until it locks into place.
Hard drive
To remove the component:
1. Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations ("SAS and
SATA hard drive LED combinations" on page 56).
2. Back up all server data on the hard drive.
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 64 65

Comentarios a estos manuales

Sin comentarios