NOTE:
NOTE:NOTE:
NOTE:
Beginning LATE May 2005, the HP R5500 XR UPS is qualified for use on HP9000 and Integrity Servers.
Description
DescriptionDescription
Description
HP UPS Solutions
HP UPS SolutionsHP UPS Solutions
HP UPS Solutions
Product Number
Product NumberProduct Number
Product Number
VA
VAVA
VA
Watts
WattsWatts
Watts
Family
FamilyFamily
Family
Supported
SupportedSupported
Supported
Software
SoftwareSoftware
Software
Output
OutputOutput
Output
AC Requirements
AC RequirementsAC Requirements
AC Requirements
J4367A
3.0 kVA
2.7 kW
HP Rack
System/E
R3000 XR
UPS
Lansafe III
and
Rack Power
Manager
200-240V
Dedicated branch circuit,
20 A
J4370A
6.0 kVA
6.0 kW
HP Rack
System/E
R6000 XR
UPS
Lansafe III
and
Rack Power
Manager
200-240V
Dedicated branch circuit,
40 A with overcurrent protection
J4373A
12.0 kVA
12.0 kW
HP Rack
System/E
R12000 XR
UPS
Lansafe III
and
Rack Power
Manager
200-240V
Dedicated branch circuit,
100 A with overcurrent protection
A1353A
*
2.0 kVA
1.4 kW
PowerTrust
II-LR
NA
120V
Dedicated branch circuit,
20 A with overcurrent protection
A1354A
*
2.0 kVA
1.4 kW
PowerTrust
II-LR
NA
230V
Dedicated branch circuit,
20 A with overcurrent protection
A1356A
*
3.0 kVA
2.1 kW
PowerTrust
II-LR
NA
230V
Dedicated branch circuit,
20 A with overcurrent protection
A6583A
*
4.5 kVA
4.0 kW
PowerTrust
II-MR
NA
230V
A6584A
*
9.0 kVA
6.5 kW
PowerTrust
II-MR
NA
230V
A6585A
*
12.0 kVA
8.0 kW
PowerTrust
II-MR
NA
230V
*
NOTE:
NOTE: NOTE:
NOTE:
Discontinued Model
Server Watt Ratings for UPS loading
Server Watt Ratings for UPS loadingServer Watt Ratings for UPS loading
Server Watt Ratings for UPS loading
Server
ServerServer
Server
Watt Rating for UPS loading
Watt Rating for UPS loadingWatt Rating for UPS loading
Watt Rating for UPS loading
(Maximum/Typical)
(Maximum/Typical)(Maximum/Typical)
(Maximum/Typical)
UPSs Typically Used
UPSs Typically UsedUPSs Typically Used
UPSs Typically Used
Approximate Battery
Approximate BatteryApproximate Battery
Approximate Battery
Runtime
RuntimeRuntime
Runtime
*
(Minutes)
(Minutes) (Minutes)
(Minutes)
rx1600
NA
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
NA
rp2400
400 W/350 W
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
40-65 minutes
rp2405
350 W/290 W
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
50 minutes
rp2430
350 W/290 W
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
50 minutes
rp2450
600 W/450 W
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
33-55 minutes
rp2470
400 W/350 W
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
40-65 minutes
rx2600
715 W/ -
J4367A HP R3000 XR UPS 2.7 kW/3.0 kVA
27 minutes
QuickSpecs
HP Uninterruptible Power Supplies
HP Uninterruptible Power SuppliesHP Uninterruptible Power Supplies
HP Uninterruptible Power Supplies
Overview
DA - 11724 Canada — Version 7 — May 2, 2005
Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 14 15

Indice de contenidos

Pagina 1 - QuickSpecs

NOTE:NOTE:NOTE:NOTE: Beginning LATE May 2005, the HP R5500 XR UPS is qualified for use on HP9000 and Integrity Servers.DescriptionDescriptionDescripti

Pagina 2

UPS Power/ ModelUPS Power/ ModelUPS Power/ ModelUPS Power/ ModelBattery PackBattery PackBattery PackBattery Pack(Quantity)UPS Total Load LevelUPS Tota

Pagina 3

HP UPS Manager II-DiscontinuedHP UPS Manager II-DiscontinuedHP UPS Manager II-DiscontinuedHP UPS Manager II-DiscontinuedHP UPS Manager II is an indust

Pagina 4

HP XR UPS-2.7 kW/3.0 kVA Unit (J4367A), 6.0 kW/6.0 kVA Unit (J4370A), and 12.0 kW/12.0 kVA Unit (J4373A)HP XR UPS-2.7 kW/3.0 kVA Unit (J4367A), 6.0 kW

Pagina 5

PowerTrust II LR-1.4 kW/2.0 kVA Unit 120V (A1353A), 1.4 kW/2.0 kVA Unit 230V (A1354A), and 2.1 kW/3.0 kVA Unit 230VPowerTrust II LR-1.4 kW/2.0 kVA Un

Pagina 6

PowerTrust II-MR-4.0-kW/4.5-kVA Unit 230V (A6583A), 6.5-kW/9-kVA Unit 230V (A6584A), and 8-kW/12-kVA Unit 230VPowerTrust II-MR-4.0-kW/4.5-kVA Unit 23

Pagina 7

Product NumberProduct NumberProduct NumberProduct NumberInput Power ConfigurationInput Power ConfigurationInput Power ConfigurationInput Power Configu

Pagina 8

rp3400 Series1350W/600 WJ4367A HP R3000 XR UPS 2.7 kW/3.0 kVAJ4370A HP R6000 XR UPS 6.0 kW/6.0 kVA326529-D71 HP R5500 XR UPS (US/Japan) 4.5 kW/5.5kVA3

Pagina 9

*NOTE: NOTE: NOTE: NOTE: Battery runtime varies with the number of UPSs, load, and number of battery modules. Extended Runtime Modules (ERMs)can be ad

Pagina 10

Continuous Power During Short Interruptions of Input PowerContinuous Power During Short Interruptions of Input PowerContinuous Power During Short Inte

Pagina 11

ProductProductProductProductNumberNumberNumberNumberOptionOptionOptionOptionNumberNumberNumberNumberNOM OutNOM OutNOM OutNOM OutOutputOutputOutputOutp

Pagina 12

HP PowerTrust II - MR (Off CPL 10/1/02)HP PowerTrust II - MR (Off CPL 10/1/02)HP PowerTrust II - MR (Off CPL 10/1/02)HP PowerTrust II - MR (Off CPL 10

Pagina 13

Lansafe IIILansafe IIILansafe IIILansafe IIILansafe III ships with, and is only supported on the HP R3000, R6000, and R12000 XR UPS products. All vers

Pagina 14

6000W/6000VA unity ratingLoad segment control with five load segments availableFront Panel LCD backlit display for easy configuration, monitoring, and

Pagina 15

HP XR UPS ERM ModulesHP XR UPS ERM ModulesHP XR UPS ERM ModulesHP XR UPS ERM ModulesExtended runtime modules extend available battery backup time in c

Comentarios a estos manuales