DESCRIPTION:
The HPT 100F is a flow-through style transmitter
while the HPT 100S is a single-ended or deadleg
style. Each style is available with a variety of tube
stub and face seal connections. Electrical connection
is via either a Bendix® compatible 4 pin connector or
a flying lead pigtail. The small size and light weight
of the HPT 100 eliminates the need for bulky
mounting hardware and mechanical supports.
FUNCTIONAL SPECIFICATIONS:
SERVICE: Liquid, gas or vapor
AVAILABLE RANGES: vac to 100 psig, vac to 250 psig, vac to 1000 psig,
vac to 2000 psig, vac to 3000 psig. Alternate ranges, including
Bar and lower ranges, are available.
OUTPUT: 4-20 mA, 2 wire, current limited with
reverse polarity protection or
0-5 Vdc (Calibrated 0.1- 5.1 Vdc)
POWER SUPPLY: 12 to 30 Vdc
LOOP RESISTANCE (4 - 20 mA.): 900 ohms at 30 Vdc; 0 ohms at 12 Vdc
OUTPUT LOAD (0 - 5 Vdc): > 50K ohms
SPAN/ZERO ADJUSTMENT: +/- 5% of span minimum
TEMPERATURE LIMITS:
COMPENSATED: 0
O
C to 50
O
C
OPERATING: -25
O
C to 85
O
C
STORAGE: -40
O
C to 85
O
C
HUMIDITY: 0-95% RH (pigtail cable) *
0-95% RH (Bendix
® type >=500 psig)
0-80% RH (Bendix
® type <500 psig)
OVERRANGE: 150% of Full Scale
BURST PRESSURE: 400% of Full Scale
HAZARDOUS LOCATIONS:
INTRINSICALLY SAFE: Class I, Division 1, Groups A, B, C & D, NEMA 4X (IP56)
Approved Barrier Required
DIVISION 2: Class I, Division 2, Groups A, B, C & D, NEMA 4X
Protective Enclosure or Conduit Connection Required
Note: NEMA 4X/IP56 applies to pigtail terminations version only
*(vent through cable to dry environment)
DIELECTRIC ISOLATION: 100V DC