__________ This bulletin supersedes TB 9-6625-1996-35, dated 13 November 1985. *TB 9-6625-1996-35 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATI
TB 9-6625-1996-35 10 a. Performance Check (1) Mount circuit board A6 (fig. 1) on extender boards. (2) Connect multimeter between A6TP6 and +
TB 9-6625-1996-35 11 R18+15VRETTP2 -15V RETA7 CIRCUIT BOARD S/N 1428AR24TP7 TP3R29-5.2 VRETTP6+5VRETR19A6 CIRCUIT BOARD R16R17TP1+15V RET A7 CIRCUIT
TB 9-6625-1996-35 12 12. Final Procedure a. Deenergize and disconnect all equipment. b. Annotate and affix DA label/form in accordance with TB 7
TB 9-6625-1996-35 PIN: 046669-000 By Order of the Secretary of the Army: Distribution: To be distributed in accordance with IDN 342172, requi
TB 9-6625-1996-35 2 SECTION I IDENTIFICATION AND DESCRIPTION 1. Test Instrument Identification. This bulletin provides instructions for the calibrat
TB 9-6625-1996-35 3 SECTION II EQUIPMENT REQUIREMENTS 4. Equipment Required. Table 2 identifies the specific equipment to be used in this calibratio
TB 9-6625-1996-35 4 SECTION III CALIBRATION PROCESS 6. Preliminary Instructions a. The instruction outlined in paragraphs 6 and 7 are preparatory
TB 9-6625-1996-35 5 (4) SAMPLE RATE control fully ccw. (5) CHANNEL A and B LEVEL controls to PRESET. (6) CHANNEL A and B SLOPE switches to +
TB 9-6625-1996-35 6 9. Sensitivity a. Performance Check (1) Set function generator as listed in (a) through (c) below: (a) Output Type to Un
TB 9-6625-1996-35 b. Adjustments (1) Substitute signal generator for function generator. (2) Connect signal generator RF OUTPUT connector to
TB 9-6625-1996-35 8 (10) Repeat (8) and (9) above as required to compensate for interaction. (11) Disconnect oscilloscope and signal generator fro
TB 9-6625-1996-35 9 A:00I1 CHAN A TRIG LEVEL 1.9995 2.0005 b2 B000I1 CHAN B TRIG LEVEL -2.0005 -1.9995 b3 B:00I1 CHAN B TRIG LEVEL 1.9995 2
Comentarios a estos manuales