HP B-series Switch Accelerators ESXi/ESX Manual de usuario

Busca en linea o descarga Manual de usuario para Servidores HP B-series Switch Accelerators ESXi/ESX. HP B-series Switch Accelerators ESXi/ESX User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 58
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP IO Accelerator version 3.1.1 VMware ESX and
ESXi
User Guide
Abstract
This document describes software requirements for all relevant HP IO Accelerators using VMware ESX or ESXi operating systems.
This document is
intended for system administrators who
plan to install and use HP IO Accelerators with a VMware ESX or ESXi operating system. It is helpful to have
previous experience with HP IO Accelerators and a VMware ESX or ESXi operating system. This user guide is intended for IO Acc
elerator software
release 3.1.1 or later.
Part Number: 682240-001
May 2012
Edition: 1
Vista de pagina 0
1 2 3 4 5 6 ... 57 58

Indice de contenidos

Pagina 1 - User Guide

HP IO Accelerator version 3.1.1 VMware ESX and ESXi User Guide Abstract This document describes software requirements for all relevant HP IO Acceler

Pagina 2

Introduction 10 • Sufficient RAM to operate—The amount of RAM that the driver requires to manage the NAND flash varies according to the block size

Pagina 3 - Contents

Introduction 11 IO Accelerators cannot be installed as part of an ESX or ESXi installation.

Pagina 4 - Contents 4

Software installation 12 Software installation VMDirectPathIO The VSL software is only required for ESX or ESXi if you plan to use the IO Accelerato

Pagina 5 - About this guide

Software installation 13 Installation overview Before installing the IO Accelerator driver, make sure you have properly installed the IO Accelerator

Pagina 6 - Introduction

Software installation 14 Transferring the VSL files to the ESX or ESXi server You must transfer the firmware file to the ESX or ESXi host. Depending

Pagina 7 - Performance attributes

Software installation 15 Installing the VSL on ESXi 5.0 These instructions describe how to install the VSL on a single hypervisor. However, if you a

Pagina 8 - Supported hardware

Software installation 16 Installing the VSL on ESX or ESXi 4.x using vCLI IMPORTANT: Do not save the installation bundles to the ESX or ESXi 4.x

Pagina 9 - Introduction 9

Software installation 17 NOTE: When using PCI pass-through, if you upgrade the firmware on an IO Accelerator, you must cycle the power for the ch

Pagina 10 - Before you begin

Software installation 18 CAUTION: Upgrading IO Accelerator devices that were previously configured for VSL 1.x.x or 2.x.x to work with VSL 3.x.x r

Pagina 11 - Introduction 11

Software installation 19 c. Reboot the system. 4. Update the firmware on each device to the latest version using the fio-update-iodrive TSM or COS

Pagina 12 - Software installation

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Pagina 13 - Installation overview

Software installation 20 CAUTION: ESX and ESXi require 512B sector sizes. New IO Accelerator devices come pre-formatted with 512B sector sizes fro

Pagina 14 - • SCP (using SSH)

Software installation 21 An ESXi host has the following: • Memory capacity of 36,852 MB • Total IO Accelerator device datastore capacity of 320 GB

Pagina 15

Maintenance 22 Maintenance Maintenance tools The IO Accelerator includes both software utilities to maintain the device and external LED indicators

Pagina 16

Maintenance 23 Command line utility Purpose fio-format (on page 32) Used to perform a low-level format of an IO Accelerator fio-pci-check (ESX only)

Pagina 17 - Upgrading procedure

Maintenance 24 Important considerations • If you are installing more than one dual IO Accelerator device and enabling the override parameter for ea

Pagina 18

Maintenance 25 1149D0969,1159E0972,24589 NOTE: The remote option (--server) is only required for the vCLI. 3. Reboot the system to enable the

Pagina 19 - Enabling PCIe power

Maintenance 26 Disabling auto attach When the IO Accelerator driver is installed, it is configured to automatically attach any devices when the driv

Pagina 20

Maintenance 27 vihostupdate --server <server-name> --query Sample output: ---------Bulletin ID--------- iomemory-vsl-2.2.0.7601742 -----Instal

Pagina 21 - Software installation 21

Performance and tuning 28 Performance and tuning Introduction to performance and tuning HP IO Accelerator devices provide high bandwidth and high IO

Pagina 22 - Maintenance

Utilities 29 Utilities Utilities reference These command-line utilities are only accessible through VMware TSM, also known as SSH, on ESXi and the C

Pagina 23 - Enabling PCIe power override

Contents 3 Contents About this guide ...

Pagina 24

Utilities 30 NOTE: If multiple IO Accelerator devices are installed in a computer, they attach in parallel. Syntax fio-attach <device> [

Pagina 25 - Common maintenance tasks

Utilities 31 NOTE: If the utility recommends that you contact Fusion-io support, disregard that message and contact HP support (http://www.hp.com

Pagina 26 - Enabling auto attach

Utilities 32 For example, the filename for a bug report file named fio-bugreport-20111006.173256-sc07HE.tar.gz indicates the following: • Date (201

Pagina 27 - Unmanaged shutdown issues

Utilities 33 Syntax fio-format [options] <device> where <device> is the name of the device node (/dev/fctx), where x indicates the card

Pagina 28 - Performance and tuning

Utilities 34 fio-pci-check [options] Options Description -d <value> 1 = Disable the link; 0 = bring the link up (HP does not recommend this

Pagina 29 - Utilities

Utilities 35 IMPORTANT: Starting with version 3.0.0 and later, the standard formatting of the fio-status output changed. The changing of the forma

Pagina 30

Utilities 36 o Date of manufacture o Power loss protection status o PCIe bus voltage (average, minimum, maximum) o PCIe bus current (average, max

Pagina 31 - Utilities 31

Utilities 37 To ensure a clean firmware update, you must detach the device from the system using the fio-detach utility. For more information, see &

Pagina 32 - • Date (20111006)

Utilities 38 CAUTION: Use the -f option with care because it might damage your board. CAUTION: Use the {{-d}} option with care, because upda

Pagina 33

Monitoring IO Accelerator health 39 Monitoring IO Accelerator health NAND flash and component failure The IO Accelerator is a highly fault-tolerant

Pagina 34

Contents 4 Introduction to performance and tuning ...

Pagina 35 - Utilities 35

Monitoring IO Accelerator health 40 Lifetime data volumes: Physical bytes written: 6,423,563,326,064 Physical bytes read : 5,509,006,756,312 Fl

Pagina 36 - • Block device information

Module parameters 41 Module parameters Using module parameters The following table describes the module parameters you can set using the esxcfg-modu

Pagina 37

VMDirectPathIO 42 VMDirectPathIO Working with IO Accelerators and VMDirectPathIO Each IO Accelerator device can either be used as a VMFS datastore i

Pagina 38 - Utilities 38

Resources 43 Resources Subscription service HP recommends that you register your product at the Subscriber’s Choice for Business website (http://www

Pagina 39 - Health monitoring techniques

Support and other resources 44 Support and other resources Before you contact HP Be sure to have the following information available before you call

Pagina 40

Support and other resources 45 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Pagina 41 - Module parameters

Support and other resources 46 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Pagina 42 - VMDirectPathIO

Support and other resources 47 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Pagina 43 - Resources

Support and other resources 48 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Pagina 44 - Support and other resources

Support and other resources 49 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Pagina 45

About this guide 5 About this guide Contents summary • Instructions on downloading and installing the approved driver and utilities • Instructions

Pagina 46 - Customer Self Repair

Support and other resources 50

Pagina 47

Support and other resources 51

Pagina 48 - Reparo feito pelo cliente

Regulatory compliance notices 52 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Pagina 49

Regulatory compliance notices 53 Disposal of waste equipment by users in private households in the European Union This symbol on the product or o

Pagina 50

Acronyms and abbreviations 54 Acronyms and abbreviations CIM common information model COS console operating system DA direct attached DVFS dynami

Pagina 51

Acronyms and abbreviations 55 VM Virtual Machine VMDK virtual machine disk format VMFS virtual machine file system VSL virtual storage layer VUM

Pagina 52 - • EMC Directive 2004/108/EC

Documentation feedback 56 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Pagina 53 - Korean class A notice

Index 57 A About this guide 5 authorized reseller 44 B before you begin 10 C command-line installation 12 command-line utilities 22 config

Pagina 54 - Acronyms and abbreviations

Index 58 P PCIe power override, enabling 23 PCIe power, enabling 19 performance and tuning 28 performance and tuning, introduction 28 perfor

Pagina 55

Introduction 6 Introduction Overview Designed around ioMemory, a revolutionary storage architecture, HP IO Accelerator is an advanced NAND flash sto

Pagina 56 - Documentation feedback

Introduction 7 Performance attributes IO Accelerator capacity Models AJ878B and BK836A 320GB 640GB NAND type MLC (Multi Level Cell) MLC (Multi Le

Pagina 57 - Index 57

Introduction 8 CAUTION: Version 3.1.1 of the driver software is not backward-compatible. When you install version 3.1.1, you cannot revert to any

Pagina 58 - Index 58

Introduction 9 BladeSystem c-Class IO Accelerators have two distinct designs for the respective server product lines. The G1 through G7 IO Accelerat

Comentarios a estos manuales

Sin comentarios