Pagina 1 - User Guide

HP P63x0/P65x0 Enterprise Virtual ArrayUser GuideAbstractThis document describes the hardware and general operation of the P63x0/P65x0 EVA.HP Part Num

Pagina 2

Spanish laser notice...206Recycling notices...

Pagina 3 - Contents

Microsoft MPIO support allows the initiator to log in to multiple sessions to the same target andaggregate the duplicate devices into a single device

Pagina 4 - 4 Contents

1. Check the box for Multipath I/O in the Add Features page.Figure 37 Add Features page2. Click Next and then click Install.3. After the server reboot

Pagina 5 - Contents 5

Figure 38 MPIO Properties page before rebootNOTE: You must present a virtual disk to the initiator to enable the Add support for iSCSIdevices checkbox

Pagina 6 - 6 Contents

Installing the MPIO feature for Windows Server 2008NOTE: Microsoft Windows 2008 includes a separate MPIO feature that requires installation foruse. Mi

Pagina 7 - Contents 7

Figure 42 MPIO Properties page after reboot4. A final reboot is required to get the devices MPIO-ed.Installing the MPIO feature for Windows Server 200

Pagina 8 - 8 Contents

About Microsoft Windows Server 2003 scalable networking packThe Microsoft Windows Server 2003 Scalable Networking Pack (SNP) contains functionality fo

Pagina 9 - Contents 9

Set up the iSCSI Initiator for Apple Mac OS X1. Install the ATTO iSCSI Macintosh Initiator v3.10 following the install instructions provided bythe ven

Pagina 10 - 10 Contents

3. For iSNS discovery:a. Select Initiator and then enter the iSNS name or IP address in the iSNS Address field(Figure 46 (page 107)).Figure 46 iSNS di

Pagina 11 - Contents 11

i. Select Status, select Network Node, and then select Login to connect to the module'starget (Figure 48 (page 108)).The Network Node displays a

Pagina 12 - 12 Contents

Storage setup for Apple Mac OS X1. Present LUNs using HP P6000 Command View.2. Verify that the EVA LUNs are presented to the Macintosh iSCSI Initiator

Pagina 14 - Front view

Figure 50 Configure initiator and targets3. Click the Discovered Targets tab and enter your iSCSI target IP address (Figure 51 (page 110)).Figure 51 D

Pagina 15 - Disk drives

Figure 52 Target login5. Click the Connected Targets tab, and then click the Toggle Start-Up button on each targetlisted so the targets start automati

Pagina 16 - Front status and UID module

1. Use the iscsiadm command to control discovery and connectivity:# iscsiadm –m discovery –t st –p 10.6.0.33:32602. Edit the initiator name:# vi /etc/

Pagina 17 - Fan module

applications or operating system utilities to use the standard SCSI device nodes to access iSCSIdevices can result in sending SCSI commands to the wro

Pagina 18 - I/O module

NOTE: Because of the way Linux dynamically allocates SCSI device nodes as SCSI devices arefound, the driver does not and cannot ensure that any partic

Pagina 19 - Rear power and UID module

Presenting EVA storage for LinuxTo set up LUNs using HP P6000 Command View:1. Set up LUNs using HP P6000 Command View. For procedure steps, see Step 2

Pagina 20

Figure 55 Firewall Properties dialog boxd. Select the Software iSCSI check box for to enable iSCSI traffic.e. Click OK.4. Enable the iSCSI software in

Pagina 21 - Controller enclosure

Figure 57 Add Send Target Server dialog boxd. Enter the iSCSI IP address of the iSCSI or iSCSI/FCoE module.e. Click OK.6. To verify that the LUNs are

Pagina 22

MPxIO overviewThe Oracle multipathing software (MPxIO) provides basic failover and load-balancing capabilityto HP P6000, and EVA4x00/6x00/8x00 storage

Pagina 23

2. Modify load balancing to none:load-balance="none";3. Modify auto-failback to disable:auto-failback="disable";4. Add the followi

Pagina 24 - Controller status indicators

Restoring iSCSI or iSCSI/FCoE module configuration and persistent data...267E Simple Network Management Protocol...

Pagina 25 - Controller status LEDs

...# devices on your system. Please refer to sgen(7d) for details.## sgen may be configured to bind to SCSI devices exporting a particular device# ty

Pagina 26

To enable iSCSI target discovery:1. Enable Sendtargets discovery:# iscsiadm modify discovery –t enable2. Verify SendTargets setting is enabled:# iscsi

Pagina 27 - Battery module

Target: iqn.2004-09.com.hp.fcgw.mez50.1.01.50014380025da538 Alias: - Bi-directional Authentication: disabled Authentication Type:

Pagina 28 - Management module

3. mpathadm show lu ‘logical-unit’This command lists details regarding a specific logical unit. This command can help verifysymmetric mode, load balan

Pagina 29 - HSV controller cabling

7. Select the desired options on the Load Balance Policy menu to set the policy.Figure 59 iSCSI Initiator MPIO propertiesLoad balancing features of Mi

Pagina 30 - Storage system racks

Microsoft MPIO with QLogic iSCSI HBAThe QLogic iSCSI HBA is supported in a multipath Windows configuration that is used in conjunctionwith Microsoft i

Pagina 31 - Power distribution units

2. Click Yes to start the general configuration wizard (see Figure 62 (page 126)). Use the Wizardto:• Choose iSCSI HBA port to configure the QLogic iS

Pagina 32 - 32 P63x0/P65x0 EVA hardware

Figure 63 HBA Port Target Configuration3. Repeat Steps 1 and 2 to add each additional iSCSI or iSCSI/FCoE target iSCSI port.4. Click Next.5. To enable

Pagina 33 - Moving and stabilizing a rack

1. Follow procedures in Step 2 to:• Create an iSCSI host.• Present LUNs to the iSCSI host.2. On the iSCSI HBA tab (Figure 65 (page 128) verify that th

Pagina 34 - 34 P63x0/P65x0 EVA hardware

Figure 66 Example: HP MPIO DSM Manager with iSCSI devicesMicrosoft Windows Cluster supportMicrosoft Cluster Server for Windows 2003iSCSI failover clus

Pagina 35 - 2. Leveler foot

1 P63x0/P65x0 EVA hardwareThe P63x0/P65x0 EVA contains the following components:• EVA controller enclosure — Contains HSV controllers, power supplies,

Pagina 36 - 2 P63x0/P65x0 EVA operation

Figure 67 iSCSI Persistent Reservation Setup window3. Click Done to finish.Each cluster is required to have its own value, and each node of a single c

Pagina 37

Setting up authenticationChallenge Handshake Authentication Protocol (CHAP) is an authentication protocol used for securelogon between the iSCSI Initi

Pagina 38 - Implicit LUN transition

Linux version• CHAP is supported with Linux open-iscsi Initiator and the iSCSI or iSCSI/FCoE modules.• CHAP setup with Linux iSCSI Initiator is not su

Pagina 39 - Handling fiber optic cables

Table 22 iSCSI or iSCSI/FCoE module secret settingsMS Initiator secret settingsiSCSI or iSCSI/FCoE module secret settingsSetting (example)ActionSettin

Pagina 40 - Powering on disk enclosures

2. Enable CHAP for the Microsoft iSCSI Initiator:a. Click Discovery.• For manually discovering iSCSI target portals:a. Click Add under Target Portals.

Pagina 41 - Starting the storage system

Enable CHAP for the Microsoft iSCSI Initiator1. Click Discovery. For manually discovering iSCSI target portals:a. Click Add under Target Portals.b. En

Pagina 42 - 42 P63x0/P65x0 EVA operation

6. Using the iscsiadm do a login into the iSCSI Target. For example:[root@sanergy33 iscsi]# iscsiadm --mode node --targetname iqn.2004-09.com.hp.fcgw.

Pagina 43 - Using the management module

1. Enable CHAP for the iSCSI or iSCSI/FCoE controller-discovered iSCSI Initiator entry. CHAPcan be enabled via CLI only.To enable CHAP for the iSCSI o

Pagina 44 - 44 P63x0/P65x0 EVA operation

3. Enable CHAP for the Microsoft iSCSI Initiator.a. Click the General tab.b. Click Secret in the middle of the screen.c. Click Reset.d. Enter the iSCS

Pagina 45

1. Enable CHAP for the iSCSI or iSCSI/FCoE controller discovered iSCSI Initiator entry. CHAPcan be enabled via CLI only.To enable CHAP for the iSCSI o

Pagina 46 - 46 P63x0/P65x0 EVA operation

Rear view7. UID push button and LED4. I/O module A1. Power supply 18. Enclosure status LEDs5. I/O module B2. Power supply 29. Power push button and LE

Pagina 47

3. Enable CHAP for the Microsoft iSCSI Initiator.a. Click the General tab.b. Click Secret in the middle of the screen.c. Click Reset.d. Enter the iSCS

Pagina 48 - 48 P63x0/P65x0 EVA operation

1. Enable CHAP for the iSCSI or iSCSI/FCoE controller discovered iSCSI Initiator entry. CHAPcan be enabled via CLI only. To enable CHAP for the iSCSI

Pagina 49

4. Enable CHAP for the Microsoft iSCSI Initiator.a. Click the General tab.b. Click Secret in the middle of the screen.c. Click Reset.d. Enter the iSCS

Pagina 50 - Multipathing

3. Setup Username and Password for Initiator and Portal for Discovery Session. For example:# To set a discovery session CHAP username and password for

Pagina 51 - Adding hosts

iSCSI and FCoE thin provision handlingiSCSI and FCoE presented LUNs which experience the thin provision (TP) Overcommitted state, asdetected by P6000

Pagina 52 - Scanning the bus

Figure 69 or Windows 2008 initiator iSCSIpresented LUN reported as TP OvercommittedLists of all presented LUNs, per Virtual Port Group, are always ava

Pagina 53 - HP-UX 53

Figure 70 iSCSI Host presented LUNs listFigure 71 (page 147) shows an iSCSI LUN being re-presented.146 iSCSI or iSCSI/FCoE configuration rules and gui

Pagina 54 - Accessing IBM AIX utilities

Figure 71 iSCSI LUN re-presented to iSCSI initiator, after clearing TP Overcommitted stateThe normal condition is illustrated in Figure 72 (page 148).

Pagina 55 - Installing a QLogic driver

Figure 72 Normal view of iSCSI LUN presented to iSCSI initiator148 iSCSI or iSCSI/FCoE configuration rules and guidelines

Pagina 56 - Upgrading Linux components

6 Single path implementationThis chapter provides guidance for connecting servers with a single path host bus adapter (HBA)to the Enterprise Virtual A

Pagina 57 - Using the source RPM

Rear view7. UID push button and LED4. I/O module A1. Power supply 18. Enclosure status LEDs5. I/O module B2. Power supply 29. Power push button and LE

Pagina 58

Because of the risks of using servers with a single path HBA, HP recommends the following actions:• Use servers with a single path HBA that are not mi

Pagina 59 - Adding OpenVMS hosts

Figure 73 Single path HBA server without OpenVMS6. SAN switch 11. Network interconnection7. SAN switch 22. Single HBA server (Host 1)8. Fabric zone3.

Pagina 60

HP-UX configurationRequirements• Proper switch zoning must be used to ensure each single path HBA has an exclusive path toits LUNs.• Single path HBA s

Pagina 61

Figure 75 HP-UX configuration5. SAN switch 11. Network interconnection6. SAN switch 22. Single HBA server (Host 1)7. Controller A3. Dual HBA server (H

Pagina 62

NOTE: For additional risks, see “Windows Servers” (page 165).Limitations• HP P6000 Continuous Access is not supported with single path configurations.

Pagina 63 - Oracle Solaris 63

Risks• Single path failure will result in loss of connection with the storage system.• Single path failure may cause the server to reboot.• Controller

Pagina 64

becomes an ordinary virtual disk, you may present that virtual disk as you would any otherordinary virtual disk.• HBA must be properly configured to w

Pagina 65 - Fabric setup and zoning

OpenVMS configurationRequirements• Switch zoning or controller level SSP must be used to ensure each single path HBA has anexclusive path to its LUNs.

Pagina 66

Limitations• HP P6000 Continuous Access is not supported with single path configurations.Figure 79 OpenVMS configuration5. SAN switch 11. Network inte

Pagina 67

Risks• Single path failure may result in data loss or disk corruption.Limitations• HP P6000 Continuous Access is not supported with single path config

Pagina 68 - 50001fe1002709e9,5

DescriptionLED statusLED colorLEDLocate driveSlow blinking (0.5 Hz)Blue1. Locate/FaultDrive faultSolidAmberDrive is spinning up or downand is not read

Pagina 69 - Oracle Solaris 69

HBA configuration• Host 1 is a single path HBA.• Host 2 is a dual HBA host with multipathing software.See Figure 81 (page 160).Risks• Single path fail

Pagina 70 - Configuring an ESX server

controller. In the case of snapclones, after the cloning process has completed and the clonebecomes an ordinary virtual disk, you may present that vir

Pagina 71 - VMware 71

IBM AIX configurationRequirements• Switch zoning or controller level SSP must be used to ensure each single path HBA has anexclusive path to its LUNs.

Pagina 72

Figure 83 IBM AIX Configuration5. SAN switch 11. Network interconnection6. SAN switch 22. Single HBA server (Host 1)7. Controller A3. Dual HBA server

Pagina 73 - System prerequisites

Limitations• HP P6000 Continuous Access is not supported with single path configurations.• Single HBA path at the host server is not part of a cluster

Pagina 74 - Installing the VAAI Plug-in

Failure effectFault stimulusShort term: Data transfer stops. Possible I/O errors.Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted

Pagina 75 - VMware 75

Failure effectFault stimulusto a different served path. When the single-path nodecrashes, only the processes executing on that node fail.In either cas

Pagina 76

Failure effectFault stimulusShort: I/O suspended, possible data loss.Long: I/O halts with I/O errors, data loss. HBA driver must be reloadedbefore fai

Pagina 77

Failure effectFault stimulusShort: I/O suspended, possible data loss.Long: I/O halts with I/O errors, data loss. HBA driver must be reloadedbefore fai

Pagina 78

7 TroubleshootingIf the disk enclosure does not initializeIMPORTANT: After a power failure, the system automatically returns to the last-powered state

Pagina 79 - VMware 79

Unit identification (UID) buttonThe unit identification (UID) button helps locate an enclosure and its components. When the UIDbutton is activated, th

Pagina 80 - Uninstalling the VAAI Plug-in

Is the power on/standby button LED amber?Possible SolutionsPossible ReasonsAnswerNo action required.System functioning properly.NoYes• Firmly press th

Pagina 81 - VMware 81

Is the fan LED amber?ActionsPossible ReasonsAnswersNo action requiredFunctioning properly.NoFan might not be inserted properly,might have a damaged co

Pagina 82 - 4 Replacing array components

To minimize the likelihood of fatal system errors, take these precautions when removing faileddrives:• Do not remove a degraded drive if any other dri

Pagina 83 - Replaceable parts

When automatic data recovery has finished, the online LED of the replacement drive stops blinkingand begins to glow steadily.Failure of another drive

Pagina 84

Table 26 Controller status LEDs (continued)IndicationLEDItemFlashing amber indicates a controller termination, or the system is inoperativeand attenti

Pagina 85 - Replacement instructions

2. 2. In HP P6000 Command View, click the General tab and then click the Locate button. Usethe Locate ON and Locate OFF buttons to control the blue LE

Pagina 86 - 86 Replacing array components

Issue: Initiator cannot login to iSCSI or iSCSI/FCoE module targetSolution 1: Ensure the correct iSCSI port IP address is usedSolution 2: In HP P6000

Pagina 87

Figure 90 Host detailsFigure 91 Target tabIssue: Windows initiators may display Reconnecting if NIC MTU changes after connection haslogged in.Solution

Pagina 88 - Figure 25 FCoE support

2. Enter a valid IPv4 mgmt Ip address under Mgmt Port and click the Save changes button. Ifonly IPv6 mgmt port IP address is set, enter a valid lPv6 m

Pagina 89

There can be a mismatch on the Vdisk allocated size incomparison with the host volume size shown by optimizer(slab count and volume information).Volum

Pagina 90

Fan module LEDOne bi-color LED provides module status information.DescriptionLED statusLED colorNo powerOffOffThe module is being identifiedBlinkingGr

Pagina 91

8 Error messagesThis list of error messages is in order by status code value, 0 to 243.Table 27 Error MessagesHow to correctMeaningStatus code valueNo

Pagina 92

Table 27 Error Messages (continued)How to correctMeaningStatus code valueIn the following cases, the messagecan occur because the operation isThe supp

Pagina 93 - IP network requirements

Table 27 Error Messages (continued)How to correctMeaningStatus code valueCase 1: Either delete the associatedobject or resolve the in progress state.S

Pagina 94 - Set up the iSCSI Initiator

Table 27 Error Messages (continued)How to correctMeaningStatus code valueReport the error to product support.The operation cannot be performed because

Pagina 95 - Set up the iSCSI Initiator 95

Table 27 Error Messages (continued)How to correctMeaningStatus code valueConfigure the virtual disk to be amember of a Continuous Access groupand retr

Pagina 96

Table 27 Error Messages (continued)How to correctMeaningStatus code valueCase 1: If this operation is still desired,delete one or more of the items an

Pagina 97 - Set up the iSCSI Initiator 97

Table 27 Error Messages (continued)How to correctMeaningStatus code valueReport the error to product support.This error is no longer supported.68Obsol

Pagina 98

Table 27 Error Messages (continued)How to correctMeaningStatus code valueResolve the condition by setting theusage to a reserved state, wait for theTh

Pagina 99

Table 27 Error Messages (continued)How to correctMeaningStatus code valueCorrectly select the remote ContinuousAccess group retry the request.The remo

Pagina 100

Table 27 Error Messages (continued)How to correctMeaningStatus code valueSnapclone ActiveWait several minutes for the driveenclosure code load to fini

Pagina 101 - Figure 37 Add Features page

I/O module LEDsLEDs on the I/O module provide status information about each I/O port and the entire module.NOTE: The following image illustrates LEDs

Pagina 102

Table 27 Error Messages (continued)How to correctMeaningStatus code valueEnsure other OCP is on and try again.If the problem persists, report the erro

Pagina 103

Table 27 Error Messages (continued)How to correctMeaningStatus code valueCode load the EVA firmware with asupported method.An unsupported code load at

Pagina 104

Table 27 Error Messages (continued)How to correctMeaningStatus code valueRemove an adapter connection beforeattempting the command again.The system ha

Pagina 105

Table 27 Error Messages (continued)How to correctMeaningStatus code valueCorrect the list such that only one typeof drive is used.The supplied list of

Pagina 106

Table 27 Error Messages (continued)How to correctMeaningStatus code valueVerify/re-establish communication tothe remote site.Attempt to create a data

Pagina 107

Table 27 Error Messages (continued)How to correctMeaningStatus code valueRetry the operation later. If the errorpersists, report the error to products

Pagina 108 - Figure 48 Select status

Table 27 Error Messages (continued)How to correctMeaningStatus code valueReport the error to product support.The event was not found.242Event Not Foun

Pagina 109

9 Support and other resourcesContacting HPHP technical supportFor worldwide technical support information, see the HP support website:http://www.hp.co

Pagina 110

• HP Software Downloads:http://www.hp.com/support/manuals• HP Software Depot:http://www.software.hp.com• HP Single Point of Connectivity Knowledge (SP

Pagina 111

parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repaircan be accomplished by CSR.For more information about

Pagina 112 - Assigning device names

© Copyright 2011, 2013 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice. The only warrant

Pagina 113 - Target bindings

Rear power and UID module LEDsDescriptionStatusLED colorLED iconLEDNot being identified or nopowerOffBlue1. UIDUnit is being identified, eitherfrom th

Pagina 114 - Unmounting file systems

A Regulatory compliance noticesRegulatory compliance identification numbersFor the purpose of regulatory compliance certifications and identification,

Pagina 115

off and on, the user is encouraged to try to correct the interference by one or more of the followingmeasures:• Reorient or relocate the receiving ant

Pagina 116

This compliance is indicated by the following conformity marking placed on the product:This marking is valid for non-Telecom products and EUharmonized

Pagina 117

Class B equipmentTaiwanese noticesBSMI Class A noticeTaiwan battery recycle statementTurkish recycling noticeTürkiye Cumhuriyeti: EEE Yönetmeliğine Uy

Pagina 118 - MPxIO overview

Laser compliance noticesEnglish laser noticeThis device may contain a laser that is classified as a Class 1 Laser Product in accordance withU.S. FDA r

Pagina 119 - Edit the sgen.conf file

German laser noticeItalian laser noticeJapanese laser noticeLaser compliance notices 205

Pagina 120 - Create an sgen driver alias

Spanish laser noticeRecycling noticesEnglish recycling noticeDisposal of waste equipment by users in private household in the European UnionThis symbo

Pagina 121 - 1.01.50014380025da538

Dutch recycling noticeInzameling van afgedankte apparatuur van particuliere huishoudens in de Europese UnieDit symbool betekent dat het product niet m

Pagina 122

Hungarian recycling noticeA hulladék anyagok megsemmisítése az Európai Unió háztartásaibanEz a szimbólum azt jelzi, hogy a készüléket nem szabad a ház

Pagina 123

Portuguese recycling noticeDescarte de equipamentos usados por utilizadores domésticos na União EuropeiaEste símbolo indica que não deve descartar o s

Pagina 124

Unit identification (UID) buttonThe unit identification (UID) button helps locate an enclosure and its components. When the UIDbutton is activated, th

Pagina 125

Battery replacement noticesDutch battery noticeFrench battery notice210 Regulatory compliance notices

Pagina 126

German battery noticeItalian battery noticeBattery replacement notices 211

Pagina 127

Japanese battery noticeSpanish battery notice212 Regulatory compliance notices

Pagina 128

B Non-standard rack specificationsThe appendix provides information on the requirements when installing the P63x0/P65x0 EVA ina non-standard rack. All

Pagina 129 - Requirements

Weights, dimensions and component CG measurementsCabinet CG dimensions are reported as measured from the inside bottom of the cabinet (Z), theleading

Pagina 130

Table 29 HP UPS models and capacitiesCapacity (in watts)UPS Model1340R15002700R30004500R550012000R12000Table 30 UPS operating time limitsMinutes of op

Pagina 131 - CHAP restrictions

Table 31 Operating Shock/VibrationShock test with half sine pulses of 10 G magnitude and 10 ms duration applied in all three axes (both positive andne

Pagina 132

C Command referenceThis chapter lists and describes the P6000 iSCSI and iSCSI/FCoE module's CLI commands inalphabetical order. Each command descr

Pagina 133

AdminOpens and closes an administrator (admin) session. Any command that changes the iSCSI oriSCSI/FCoE module's configuration must be entered in

Pagina 134

Clears all entries from the module's log file.logsKeywordsResets the statistic counters.statsExamples: The following examples show the clear comm

Pagina 135

Figure 1 Controller enclosure (front bezel)2. Front UID push button1. Enclosure status LEDsFigure 2 Controller enclosure (front view with bezel remove

Pagina 136

FRUSaves and restores the module’s configuration.Admin session to restoreAuthorityrestoresaveFRUSyntaxThe fru restore command requires that you first

Pagina 137

iSCSI/FCoE module CLI command qualifieriSCSI module CLI command qualifierCLI command image list image unpack [ ] image list ima

Pagina 138

iSCSI/FCoE module CLI command qualifieriSCSI module CLI command qualifierCLI commandtracerouteiSCSI Server Connectivity Command Set:==================

Pagina 139

Example 1:MEZ50_02 (admin) #> image cleanupMEZ50_02 (admin) #> image list No images found in system.Example 2:MEZ50_02 (admin) #> image list

Pagina 140

to do so.Only valid iSCSI name characters will be accepted. Valid characters include lower-case alphabetical (a-z), numerical (0-9), colon, hyphen, a

Pagina 141

LogoutExits the command line interface and returns you to the login prompt.NoneAuthoritylogoutSyntaxExample:MEZ50 <1>(admin) #> logout(none)

Pagina 142

12 13 Please select a LUN to present to the initiator ('q' to quit): 12 All attribute values that have been changed will now b

Pagina 143

3 VPGROUP_3 4 VPGROUP_4 Multiple VpGroups are currently 'ENABLED'. Please s

Pagina 144

Index Initiator ----- ----------------- 0 iqn.1991-05.com.microsoft:perf3.sanbox.com Please se

Pagina 145

Example:MEZ50 <1>(admin) #> passwdPress 'q' and the ENTER key to abort this command.Select password to change (0=guest, 1=admin) :

Pagina 146

Figure 3 P6000 EVA FC controller enclosure (rear view)9. Enclosure power push button1. Power supply 110. Power supply 22. Controller 111. DP-A and DP-

Pagina 147

Reply from 10.6.0.194: bytes=56 time=0.1ms Reply from 10.6.0.194: bytes=56 time=0.1ms Reply from 10.6.0.194: bytes=56 time=0.1ms Reply from 10.6.

Pagina 148

SaveSaves logs and traces.Admin sessionAuthoritycapturelogstraces saveSyntaxThe save capture command creates a debug file that capturesall debug dump

Pagina 149 - 6 Single path implementation

Assigns alias name to a presented iSCSI target. Seethe “set alias command” (page 232)aliasKeywordsSets the CHAP secrets. See the “set CHAPcommand” (pa

Pagina 150 - Supported configurations

Set CHAPProvides for the configuration of the challenge handshake authentication protocol (CHAP).Admin sessionAuthorityset chapSyntaxExample:MEZ50 <

Pagina 151

Link Rate (0=Auto, 1=1Gb, 2=2Gb, 4=4Gb, 8=8GB) [Auto ] Frame Size (0=512B, 1=1024B, 2=2048B) [2048 ] Execution Thrott

Pagina 152 - HP-UX configuration

Enter feature key to be saved/activated: Set iSCSIConfigures an iSCSI port.Admin sessionAuthority[<PORT_NUM>]set iscsiSyntaxThe iSCSI port to

Pagina 153 - HBA configuration

Port Status (0=Enable, 1=Disable) [Enabled ] Port Speed (0=Auto, 1=100Mb, 2=1Gb) [Auto ] MTU Size (0=Normal

Pagina 154 - Limitations

MEZ50 <1>(admin) #> set mgmtA list of attributes with formatting and current values willfollow. Enter a new value or simply press the ENTER k

Pagina 155 - Oracle Solaris configuration

MEZ50 (admin) #> set properties A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER

Pagina 156

-------------------------------------Destination enabled (0=Enable, 1=Disable) [Disabled ]Configuring SNMP Trap Destination 8 :-----------------------

Pagina 157 - OpenVMS configuration

Figure 5 P6000 EVA iSCSI/FCoE controller enclosure (rear view)10. Power supply 21. Power supply 111. 10GbE ports 1–22. Controller 112. DP-A and DP-B,

Pagina 158 - Xen configuration

-------------------------Status (0=Enable, 1=Disable) [Enabled ]VpGroup Name (Max = 64 characters) [VPGROUP_1 ]All attribute values for VpGroup 1 that

Pagina 159 - Linux (32-bit) configuration

Displays SCSI initiator information: iSCSI or FC. Seethe “show initiators command” (page 244)initiators [fc or iscsi]Displays initiators and the LUNs

Pagina 160 - Linux (Itanium) configuration

Show CHAPDisplays CHAP configuration for iSCSI nodes.NoneAuthorityshow chapSyntaxExample:MEZ50 <1>(admin) #> show chapThe following is a list

Pagina 161

Port ID 00-00-ef (VPGROUP_1) WWNN 20:01:00:c0:dd:00:00:76 (VPGROUP_2) WWPN

Pagina 162 - IBM AIX configuration

Current Link Rate 4Gb Programmed Link Rate Auto WWNN 20:00:00:c0

Pagina 163 - VMware configuration

OS Type Windows Initiator Name iqn.1991-05.com.microsoft:perf3.sanbox.com Alias IP Address 33.33.52.17, 33.33.52.16

Pagina 164 - Failure scenarios

Type FCOE OS Type Windows2008 WWNN 20:00:00:00:c9:95:b5:73 WWPN 10:00:00:00:c9:95:b5:73 Port ID

Pagina 165 - Oracle Solaris

Please select an Initiator from the list above ('q' to quit): 0 Target(WWPN) (LUN/VpGroup) ------------ --

Pagina 166

IPv4 Address 33.33.52.96 IPv4 Subnet Mask 255.255.0.0 IPv4 Gateway Address 0.0.0.0 IPv4 Target TCP Port No. 32

Pagina 167

iSCSI Header Digests Disabled iSCSI Data Digests Disabled iSCSI Port GE4 Port Status

Pagina 168

Table 1 HSV340/360 controller port status indicatorsDescriptionPortFibre Channel host ports• Green — Normal operation• Amber — No signal detected• Off

Pagina 169 - 7 Troubleshooting

Example:MEZ75 (admin) #> show logs 03/11/2011 22:18:42 UserApp 3 User has cleared the logs 03/11/2011 22:29:23 UserApp 3 qapisetpresentedta

Pagina 170

Please select a LUN from the list above ('q' to quit): 10 LUN Information ----------------- WWULN 60:05:08:b4:00:0f:1d:4f:

Pagina 171 - Compromised fault tolerance

VPGROUP_3 0 VPGROUP_4 0 Show lunmaskDisplays all initiators mapped to a user

Pagina 172 - 172 Troubleshooting

Buffer Pool 9812/9856 Nic Buffer Pool 53427/81920 Process Blocks 8181/8192 Request Blocks 8181/8192 Event Blocks

Pagina 173 - Handling disk drive failures

Show perfDisplays the port, read, write, initiator, or target performance in bytes per second.NoneAuthority[byte | init_rbyte | init_wbyte | tgt_rbyte

Pagina 174 - Figure 86 Beacon on command

Show presented targetsDisplays targets presented by the module's FC, FCoE, or iSCSI or for all.NoneAuthorityfciscsishow presentedtargetsSyntaxSpe

Pagina 175 - Issues and solutions

Port FC3 Type FCOE <MAPS TO> WWNN 50:01:43:80:04:c6:89:60 WWPN 50:01:43:80:04:c6:89:6c VPGroup 1 WWNN 20:05

Pagina 176 - 176 Troubleshooting

VPGroup 4 WWNN 20:0b:f4:ce:46:fb:0a:44 WWPN 21:0b:f4:ce:46:fb:0a:44 Port ID ef-09-06 Port FC4 Type FCOE <MAPS TO&

Pagina 177

Port FC4 Type FCOE <MAPS TO> WWNN 50:01:43:80:04:c6:89:60 WWPN 50:01:43:80:04:c6:89:6c VPGroup 4 iSCSI Presented

Pagina 178

MEZ75 (admin) #> show properties CLI Properties ---------------- Inactivty Timer Disabled Prompt String MEZ75Show SNMPDisplays the module

Pagina 179

Table 3 Controller status LEDs (continued)IndicationLEDItemFlashing amber indicates a controller termination, or the systemis inoperative and attentio

Pagina 180 - 8 Error messages

FC Port FC3 Interrupt Count 292953354 Target Command Count 129313203 Initiator Command Coun

Pagina 181

Unexpected I/O Rcvd 0 iSCSI Format Errors 0 Header Digest Errors 0 Data Digest Errors 0 Sequ

Pagina 182

System Information -------------------- Product Name HP StorageWorks MEZ75 Symbolic Name MEZ75-1

Pagina 183

VpGroup Information --------------------- Index 1 VpGroup Name VPGROUP_1 Status Enable

Pagina 184

because the targets are auto detected and the show targets displayed information can be a helpfuldebug aid.Admin sessionAuthorityaddrmtargetSyntaxRemo

Pagina 185

D Using the iSCSI CLIThe CLI enables you to perform a variety of iSCSI or iSCSI/FCoE module management tasks throughan Ethernet or serial port connect

Pagina 186

System Information -------------------- Product Name HP StorageWorks MEZ50 Symbolic Name MEZ50-1

Pagina 187

Modifying a configurationThe module has the following major areas of configuration:• Management port configuration requires the use of the following c

Pagina 188

220 (none) FTP server (GNU inetutils 1.4.2) ready.User (172.17.137.102:(none)): ftp331 Guest login ok, type your name as password.Password: ftp230 Gue

Pagina 189

E Simple Network Management ProtocolSimple network management protocol (SNMP) provides monitoring and trap functions for managingthe module through th

Pagina 190

Table 4 Power supply LED statusDescriptionLED colorAmber• The power supply is powered up but not providing output power.• The power supply is plugged

Pagina 191

Management Information BaseThis section describes the QLogic management information base (MIB).Network port tableThe network port table contains a lis

Pagina 192

qsrNwPortAddressModeINTEGER1 = StaticSyntax2 = DHCP3 = Bootp4 = RARPRead-onlyAccessMethod by which the port gets its IP address.DescriptionqsrIPAddres

Pagina 193

qsrNwLinkRateQsrLinkRateSyntaxRead-onlyAccessOperational link rate for this port.DescriptionFC port tableThis table contains a list of the Fibre Chann

Pagina 194

qsrFcPortNodeWwnPhysAddressSyntaxRead-onlyAccessWorld wide name of the node that contains this port.DescriptionqsrFcPortWwnPhysAddressSyntaxRead-onlyA

Pagina 195

qsrIsInitEntryQsrIsInitEntrySyntaxNot accessibleAccessEach entry (row) contains information about a specific iSCSI initiator.DescriptionAn iSCSI initi

Pagina 196

qsrIsInitStatusInteger:1 = unknown,Syntax2 = loggedIn,3 = loggedOut,4 = recoveryRead-onlyAccessStatus of the iSCSI initiator, that is, whether or not

Pagina 197 - 9 Support and other resources

INTEGERqsrLunVPGroupidSnmpAdminStringqsrLunVPGroupnameqsrLunWwulnPhysAddressSyntaxRead-onlyAccessThe worldwide unique LUN name (WWULN) for the LUN.Des

Pagina 198 - Customer self repair

qsrLunVPGroupname OBJECT-TYPESnmpAdminStringSyntaxRead-onlyAccessVP group name to which this LUN belongsDescriptionVP group tableThis table contains a

Pagina 199 - Rack stability

Read-onlyAccessVP group name or host group name.DescriptionqsrVPGroupWWNNVpGroupWwnnAndWwpnSyntaxRead-onlyAccessWorldwide port number (WWPN)Descriptio

Pagina 200 - FCC rating label

qsrSensorIndexUnsigned32SyntaxNot accessibleAccessA positive integer identifying each sensor of a given type.DescriptionqsrSensorUnitsINTEGERCelsius =

Pagina 201 - European Union notice

Figure 11 Fan module pulled out2. Amber—Fan fault LED1. Green—Fan normal operation LEDTable 6 Fan status indicatorsDescriptionFault indicatorStatus in

Pagina 202 - Korean notices

System information objectsSystem information objects provide the system serial number, version numbers(hardware/software/agent), and number of ports (

Pagina 203 - Turkish recycling notice

Accessible for notifyAccessIndicates the severity of the event. The value clear specifies that a conditionthat caused an earlier trap is no longer pre

Pagina 204 - Laser compliance notices

FC notifications are sent for the following events:• Fibre Channel port: down or up• down or up Port number (1–4)Target device discoveryThe Fibre Chan

Pagina 205 - Japanese laser notice

VP group notifications are sent for the following events:• Change in name of a VP group• Enabling and disabling a VP groupSensor notificationThe senso

Pagina 206 - Recycling notices

F iSCSI and iSCSI/FCoE module log messagesThis appendix provides details about messages logged to a file. The message log is persistentbecause it is m

Pagina 207

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)Memory unavailable for LUN object.ErrorAppQLBA_CreateLunObject:LunObject memory unavailabl

Pagina 208 - Polish recycling notice

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)iSCSI login rejected due to a CHAP authenticationerror.ErrorAppQLIS_LoginPduContinue:Sessi

Pagina 209 - Swedish recycling notice

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)Attempting login but FC connection cannot beopened.ErrorAppQLFC_Login: Can't openconn

Pagina 210 - Battery replacement notices

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)iSCSI session full feature login.InfoAppQLIS_LoginPduContinue:[0x%x] SES_STATE_LOGGED_INNO

Pagina 211 - Italian battery notice

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)iSCSI processor failed diagnostic reboot.FataliSCSI#%d: qlutm_init: Diagnosticfailed, fail

Pagina 212 - Spanish battery notice

Reset the iSCSI or iSCSI/FCoE module and boot the primary imageUse a pointed nonmetallic tool to briefly press the maintenance button for a duration o

Pagina 213 - EIA310-D standards

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)iSCSI driver missed iSCSI processor heartbeat.iSCSI processor rebooted.FataliSCSI#%d: QLRe

Pagina 214 - UPS Selection

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)Driver failed to receive a heartbeat from the iSCSIprocessor for the specified number of s

Pagina 215

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)FC2 processor POST failed.FatalFC#%d: qlutm_init: Diagnosticfailed, port 2 POST failed1024

Pagina 216

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)FC processor failed the external loopback test.ErrorFC#%d: QLIoctlRunDiag:Diagnostic loopb

Pagina 217 - C Command reference

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)FC controller reported failure status for an ExecuteIOCB (input/output control block) comm

Pagina 218

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)Failed memory allocation for Get Statistics API.ErrorUserQBRPC_Initialize:GetStatsMem Allo

Pagina 219

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)iSCSI port configuration has changed.InfoUser#%d:qapisetiscsiinterfaceparams_1_svc:151890i

Pagina 220

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)Left PCM is connected AC power.InfoUsersysTempMon: Power for LeftPCM Plugged-in152133Left

Pagina 221

GlossaryThis glossary defines terms used in this guide or related to this product and is not acomprehensive glossary of computer terms.Symbols and num

Pagina 222 - Example: :

asynchronous Events scheduled as the result of a signal requesting the event or that which is without any specifiedtime relation.Bbackplane An electro

Pagina 223 - Initiator

Contents1 P63x0/P65x0 EVA hardware...13SAS disk enclosures...

Pagina 224 - Example 4:

Y-cables (Figure 12 (page 30)) are used to connect the P6500 EVA and enable each controllerdata port to act as two ports.Figure 12 P6500 Y-cable2. Por

Pagina 225 - Example:

console LUN A SCSI-3 virtual object that makes a controller pair accessible by the host before any virtual disksare created. Also called a communicati

Pagina 226

disk group A named group of disks selected from all the available disks in a disk array. One or more virtualdisks can be created from a disk group. Al

Pagina 227

Enclosure ServicesInterfaceSee ESI.Enclosure ServicesProcessorSee ESP.Enterprise VirtualArrayThe Enterprise Virtual Array is a product that consists o

Pagina 228 - 228 Command reference

fiber The optical media used to implement Fibre Channel.fiber optic cable A transmission medium designed to transmit digital signals in the form of pu

Pagina 229

host-side ports See host port.hot-pluggable The ability to add and remove elements or devices to a system or appliance while the applianceis running a

Pagina 230

loop See arbitrated loop.loop ID Seven-bit values numbered contiguous from 0 to 126 decimal that represent the 127 valid AL_PAvalues on a loop (not al

Pagina 231

Network StorageControllerSee NSC.node port A device port that can operate on the arbitrated loop topology.non-OFC (OpenFibre Control)A laser transceiv

Pagina 232 - Set alias

port A physical connection that allows data to pass between a host and a disk array.port-colored Pertaining to the application of the color of port or

Pagina 233 - Set CHAP

redundant powerconfigurationA capability of the Enterprise storage system racks and enclosures to allow continuous systemoperation by preventing singl

Pagina 234 - Set features

TTB Terabyte. A term defining either:• A data transfer rate.• A measure of either storage or memory capacity of 1,099,5111,627,776 (240) bytes.See als

Pagina 235 - Set iSCSI

http://h18004.www1.hp.com/products/servers/proliantstorage/racks/index.htmlPower distribution unitsAC power is distributed to the rack through a dual

Pagina 236 - Set Mgmt

Vraid6 Offers the features of Vraid5 while providing more protection for an additional drive failure, butuses additional physical disk space.WWorld Wi

Pagina 237 - Set properties

IndexAAC powerdistributing, 31accessingmultipathing, 50Secure Path, 50add features page, 103adding hosts, 51, 59admin command, 218agent shutdown notif

Pagina 238 - Set SNMP

EVA, 70restoring, 267saving and restoring, 267Solaris, 66connected targets tab, 111connection suspended, 185connectorsprotecting, 39controllercabling,

Pagina 239 - Set VPGroups

HP P6000 Command Viewadding hosts with, 51creating virtual disk with, 52troubleshooting, 175using, 51HP-UXcreate virtual disks, 52creating volume grou

Pagina 240

with QLogic iSCSI HBA, 125MPxIOenabling for EVA, 118multipath devices, monitoring, 122multipathing, 99accessing, 50ESX server, 71Solaris 10, 117Nnetwo

Pagina 241

set command, 231set fc command, 233set features command, 234set iscsi command, 235set isns command, 236set mgmt command, 236set ntp command, 237set pr

Pagina 242 - Show CHAP

VVdiskDR group member, 184DR log unit, 184not presented, 184Veritas Volume Manager, 66version not supported, 183vgcreate, 53virtual disksconfiguring,

Pagina 243

A PDU 2 failure:• Disables the power distribution circuit• Removes power from the right side of the PDM pairs• Disables drive enclosures PS 2• Disable

Pagina 244 - Show initiators

Rack AC power distributionThe power distribution in a rack is the same for all variants. The site AC input voltage is routed tothe dual PDU assembly m

Pagina 245

Moving the rack requires a clear, uncarpeted pathway that is at least 80 cm (31.5 in) wide forthe 60.3 cm (23.7 in) wide, 42U rack. A vertical clearan

Pagina 246 - Show initiators LUN mask

Figure 16 Raising a leveler foot1. Hex nut2. Leveler foot3. Carefully move the rack to the installation area and position it to provide the necessary

Pagina 247 - Show iSCSI

2 P63x0/P65x0 EVA operationBest practicesFor useful information on managing and configuring your storage system, see the HP P6300/P6500Enterprise Virt

Pagina 248 - 248 Command reference

Table 7 Failback preference settings (continued)BehaviorPoint in timeSettingOtherwise, the units are brought online toController 2.All LUNs are brough

Pagina 249 - Show logs

Table 8 Failback settings by operating system (continued)Supported settingsDefault behaviorOperating systemPath A/B – Failover onlyPath A/B – Failover

Pagina 250 - Show LUNinfo

When creating a virtual disk, one controller is selected to manage the virtual disk. Only thismanaging controller can issue I/Os to a virtual disk in

Pagina 251 - Show LUNs

Reserving adequate free space...36Using SAS-midline disk driv

Pagina 252 - Show memory

The transceiver dust caps protect the transceivers from contamination. Do not discard the dustcovers.CAUTION: To avoid damage to the connectors, alway

Pagina 253 - Show NTP

Powering off disk enclosuresCAUTION: Be sure that the server controller is the first unit to be powered down and the last tobe powered back up. Taking

Pagina 254 - Show perf

2. Ensure all power cords are connected to the controller enclosure and disk enclosures. Applypower to the rack PDUs.3. Apply power to the controller

Pagina 255 - Show presented targets

3. Select Restart on the iSCSI Controller Shutdown Options window (Figure 17 (page 46)).Figure 17 iSCSI Controller Shutdown OptionsThe following is an

Pagina 256 - 256 Command reference

Figure 18 Management module3. Reset button1. Status LEDs2. Ethernet jackConnecting through a public network1. Initialize the P63x0 EVA or P65x0 EVA st

Pagina 257 - Commands 257

9. Remove the LAN cable to the private network or laptop and reconnect the cable to the publicnetwork.10. From a computer on the public network, brows

Pagina 258 - Show properties

NOTE: Change your browser settings for the HP P6000 Control Panel as described in the HPP6000 Command View Installation Guide. You must have administr

Pagina 259 - Show stats

NOTE: For more information on using the utility, see the HP Storage System Scripting UtilityReference. See “Related documentation” (page 197).1. Doubl

Pagina 260 - 260 Command reference

Example 1 Saving configuration data on a Windows host1. Double-click on the SSSU desktop icon to run the application. When prompted, enter Manager(man

Pagina 261 - Show system

Figure 20 iSCSI Controller Configuration Selection windowNOTE: A Restore action will reboot the module.Saving storage system configuration data 49

Pagina 262 - Show VPGroups

Updating the AlphaServer console code, Integrity Server console code, and Fibre Channel FCAfirmware...

Pagina 263 - Shutdown

3 Configuring application serversOverviewThis chapter provides general connectivity information for all the supported operating systems.Where applicab

Pagina 264 - Traceroute

Testing connections to the arrayAfter installing the FCAs, you can create and test connections between the host server and thearray. For all operating

Pagina 265 - D Using the iSCSI CLI

Creating and presenting virtual disksTo create and present virtual disks to the host server:1. From HP P6000 Command View, create a virtual disk on th

Pagina 266 - 266 Using the iSCSI CLI

# ioscan -fnCdisk# ioscan -fnCdiskClass I H/W Patch Driver S/W H/W Type Description State=========================

Pagina 267

IBM AIXAccessing IBM AIX utilitiesYou can access IBM AIX utilities such as the Object Data Manager (ODM), on the following website:http://www.hp.com/s

Pagina 268

LinuxDriver failover modeIf you use the INSTALL command without command options, the driver’s failover mode dependson whether a QLogic driver is alrea

Pagina 269 - SNMP parameters

# modprobe qla2400To reboot the server, enter the reboot command.CAUTION: If the boot device is attached to the SAN, you must reboot the host.7. To ve

Pagina 270 - Management Information Base

# ./INSTALL -FCompiling the driver for multiple kernelsIf your system has multiple kernels installed on it, you can compile the driver for all the ins

Pagina 271

"Wrote: ...rpm".This line identifies the location of the binary RPM.4. Copy the binary RPM to the production servers and install it using th

Pagina 272 - FC port table

Console LUN ID and OS unit IDHP P6000 Command View software contains a box for the Console LUN ID on the InitializedStorage System Properties window.I

Pagina 273 - Initiator object table

Apple Mac OS X iSCSI initiator rules and guidelines...91Microsoft Windows iSCSI Initiator r

Pagina 274

6. Using the driver and device handle, enter the drvdfg —s driver_handle device_handlecommand to invoke the EFI Driver configuration utility. For exam

Pagina 275 - LUN table

NOTE: Restarting the host system shows any newly presented virtual disks because a hardwarescan is performed as part of the startup.If you are unable

Pagina 276

Loading the operating system and softwareFollow the manufacturer’s instructions for loading the operating system (OS) and software onto thehost. Load

Pagina 277 - VP group table

1. Ensure that you have the latest supported version of the lpfc driver (see http://www.hp.com/storage/spock).You must sign up for an HP Passport to e

Pagina 278 - Sensor table

7. Reboot the server to implement the changes to the configuration files.8. If LUNs have been preconfigured in the /kernel/drv/sd.conf file, use the d

Pagina 279 - Notifications

hba1-SCSI-target-id-31-fibre-channel-port-name="50001fe10027093b";NOTE: Replace the WWPNs in the example with the WWPNs of your array ports.

Pagina 280 - Notification objects

Configuring with Veritas Volume ManagerThe Dynamic Multipathing (DMP) feature of Veritas Volume Manager (VxVM) can be used for allFCAs and all drivers

Pagina 281 - FC port down notification

Example 4 Setting the I/O policy# vxdmpadm getattr arrayname EVA8100 iopolicyENCLR_NAME DEFAULT CURRENT====================================

Pagina 282

50001fe1002709e9,5• Emulex (lpfc)/QLogic (qla2300) drivers:You can retrieve the WWPN by checking the assignment in the driver configuration file(the e

Pagina 283 - Generic notification

Example 5 Format command# formatSearching for disks...donec2t50001FE1002709F8d1: configured with capacity of 1008.00MBc2t50001FE1002709F8d2: configure

Pagina 284

Linux version...132ATTO Macintosh Chap

Pagina 285

7. For each new device, use the disk command to select another disk, and then repeat 1 through6.8. Repeat this labeling procedure for each new device.

Pagina 286

Setting the multipathing policyYou can set the multipathing policy for each LUN or logical drive on the SAN to one of the following:• Most recently us

Pagina 287

You can also set the multipathing policy from the VMware Management User Interface (MUI) byclicking the Failover Paths tab in the Storage Management s

Pagina 288

Verifying virtual disks from the hostUse the VMware vCenter management GUI to check all devices (see figure below).HP P6000 EVA Software Plug-in for V

Pagina 289

NOTE: By default, the four VAAI primitives are enabled.NOTE: The EVA VAAI Plug-In is required with vSphere 4.1 in order to permit discovery of theEVA

Pagina 290

3. Placing the target VMware host in maintenance mode.4. Invoking the software tool to install the HP VAAI Plug-in.Automated installation steps includ

Pagina 291

4. Verify the installation:a. Check for new HP P6000 claim rules.Using the service console, enter:esxcli corestorage claimrule list -c VAAIThe return

Pagina 292

2. Enter maintenance mode.Enter a command using the following syntax:vicfg-hostops.pl --server Host_IP_Address --usernameUser_Name--password Account_P

Pagina 293

NOTE: VAAI device status will be "Unknown" until all VAAI primitives are attempted by ESX onthe device and completed successfully. Upon comp

Pagina 294

4. Create a new Baseline set for this offline plug-in:a. Select the Baselines and Groups tab.b. Above the left pane, click Create.c. In the New Baseli

Pagina 295

Requirements...159HBA configuration...

Pagina 296

NOTE:• In the Tasks & Events section, the following tasks should have a Completed status: Remediateentry, Install, and Check.• If any of the above

Pagina 297

Uninstalling VAAI Plug-in using VMware native tools (esxupdate)1. Enter maintenance mode.2. Query the installed VAAI Plug-in to determine the name of

Pagina 298 - Glossary

4 Replacing array componentsCustomer self repair (CSR)Table 16 (page 83) and Table 17 (page 84) identify hardware components that are customerreplacea

Pagina 299

Figure 23 Example of typical product label1. Spare component numberReplaceable partsThis product contains the replaceable parts listed in “Controller

Pagina 300 - 300 Glossary

Table 16 Controller enclosure replacement parts (continued)CSR statusSpare part numberDescription•461491–005Array riser assembly•466264–001Array power

Pagina 301

Table 17 Disk enclosure replaceable parts (continued)CSR statusSpare part numberDescription•408765-001External mini-SAS Cable, 0.5m•519318-001Rackmoun

Pagina 302 - 302 Glossary

• HP Controller Enclosure Battery Replacement Instructions• HP Controller Enclosure Cache DIMM Replacement Instructions• HP Controller Enclosure Fan M

Pagina 303

5 iSCSI or iSCSI/FCoE configuration rules and guidelinesThis chapter describes the iSCSI configuration rules and guidelines for the HP P6000 iSCSI and

Pagina 304 - 304 Glossary

Figure 24 Mixed FC and FCoE storage configuration using FC and FCoE storage targets26659bFCoE/iSCSI/FC EVA/SAS storageP6500EVAP6300EVABLADE servers w/

Pagina 305

The following is an example of a Mixed FC and FCoE storage configuration:Figure 26 Mixed FC and FCoE storage configuration26660aP6300 EVA P6500 EVAFCo

Pagina 306 - 306 Glossary

Issue: Initiator logs in to iSCSI or iSCSI/FCoE controller target but EVA assigned LUNs are notappearing on the initiator...

Pagina 307

NOTE: HP recommends that at least one zone be created for the FCoE WWNs from each portof the HP P6000 with the iSCSI/FCoE modules. The zone should als

Pagina 308 - 308 Glossary

Table 18 Operating system and multipath software supportEVA storage systemConnectivityClustersMultipath softwareOperating systemEVA4400/4400 with the

Pagina 309

iSCSI Initiator operating system considerations:• Host mode setting – Microsoft Windows 2012, Windows 2008 or Windows 2003• TCPIP parameter Tcp1323Opt

Pagina 310 - 310 Glossary

VMware iSCSI Initiator rules and guidelinesThe VMware iSCSI Initiator supports the following:• Native iSCSI software initiator in VMware ESX 4.0/3.5•

Pagina 311

Set up the iSCSI InitiatorWindowsFor Windows Server 2012 and Windows Server 2008, the iSCSI initiator is included with theoperating system. For Window

Pagina 312 - 312 Index

1. Install the HP P6000 iSCSI/FCoE and MPX200 Multifunction Router kit.a. Start the installer by running Launch.exe; if you are using a CD-ROM, the in

Pagina 313

Figure 30 iSCSI Initiator Installationc. Click the Microsoft iSCSI Initiator icon to open the Control Panel applet.The iSCSI Initiator Properties wind

Pagina 314 - 314 Index

Figure 32 iSCSI Initiator Properties—Discovery tab (Windows 2008)a. From HP P6000 Command View, click the EVA storage system icon to start the iSCSIst

Pagina 315

c. c. To create iSCSI Initiator host, click Add host.A dialog box opens.• Enter a name for the initiator host in the Name box.• Select iSCSI as the Ty

Pagina 316 - 316 Index

3. Set up the iSCSI disk on the iSCSI Initiator:a. Open the iSCSI Initiator Control Panel applet.b. Click the Targets tab and then the Refresh button

Comentarios a estos manuales