Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)
Cause of ErrorRAID Manager CommandSSB2SSB1
paircreate
pairsplit,
pairresync,
pairresync -
restore
Since you specified the
volume whose emulation
type is other than OPEN-V
as the XP Snapshot S-VOL,
the command ends
abnormally.
paircreate
pairsplit,
pairresync,
pairresync -
restore
973f
Since the volume you
specified as the XP Snapshot
S-VOL has the command
device setting, the pair
cannot be created.
paircreate9740
Since you specified an
external volume as the XP
Snapshot S-VOL, the pair
cannot be created.
paircreate9742
Since you specified the
volume other than V-VOLs as
the XP Snapshot S-VOL, the
pair cannot be created.
paircreate9745
Since you specified a
pool-VOL as the XP Snapshot
S-VOL, the pair cannot be
created.
paircreate9746
Since you specified XP
Continuous Access P-VOL as
the XP Snapshot S-VOL, the
pair cannot be created.
paircreate9747
Since you specified XP
Continuous Access S-VOL as
the XP Snapshot S-VOL, the
pair cannot be created.
paircreate9748
Since you specified XP
Continuous Access Journal
data volume or journal
volume in the intermediate
site of 3DC cascading
configuration as the XP
Snapshot S-VOL, the
Snapshot pair cannot be
created.
paircreate9749
Since you specified XP
Continuous Access Journal
P-VOL as the XP Snapshot
S-VOL, the pair cannot be
created.
paircreate974a
paircreate974b