Table 32 and Table 33 define the output voltage and current specifications of the
power supply.
Table 32: Output Voltage and Current Specifications
Specification
Range
Minimum Nominal Maximum
+5.1 VDC
Initial Voltage
Steady state current
+5.13 VDC
1.0 A
+5.18 VDC
N/A
+5.23 VDC
26.0 A
+12.2 VDC (Disk Drive Voltage)
Initial Voltage
Steady state current
+12.13 VDC
1.0 A
+12.25 VDC
N/A
+12.37 VDC
26.0 A
+12.5 VDC (Blower Voltage)
Initial Voltage
Steady state current
+12.25 VDC
0.0 A
+12.50 VDC
N/A
+12.75 VDC
2.0 A
Table 33: Dual Power Supply Configuration Power Specifications
Voltage Current (A) Power (W)
Maximum Continuous Current
+5.1 VDC (with a minimum +12.2 VDC load of
0A)
+12.2 VDC (with a minimum +5 VDC load of 4 A)
+12.5 VDC
26.0 A
28.0 A
2.0 A
132 W
342.0 W
25.0 W
Total 499.0 W
Maximum Peak Current (Simultaneous Seek Activity)
+5.1 VDC
+12.2 VDC
+12.5 VDC
26.0 A
43.0 A
2.0 A
132.0 W
524.0 W
25.0 W
Total 681.0 W