Hp 3Gb SAS Switch for HP BladeSystem c-Class Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
The following devices are used in this example:
ModelDevice type
c7000c-Class enclosure
ProLiant BL 460c G1 and ProLiant BL 465c G1Server blades
P700mSAS mezzanine cards
3Gb SAS BL Switch, installed in interconnect bays 5 and 6SAS switch blades
MDS600 storage enclosureExternal SAS storage enclosures
1. Change the Multi-initiator Mode setting to Disabled. This setting controls access to the zone
group, permitting only one server to access each zone group and its associated disk drives.
IMPORTANT: If tape autoloaders/libraries or shared SAS storage enclosures are also
connected to the switch and multiple server device bays will need access to the same switch-port
zone groups, Multi-initiator Mode must be Enabled.
a. Access VSM and select the Zoning tab.
b. Select the switch and click Advanced Settings.
c. When prompted, expand the Multi-initiator Mode drop-down box and change the setting
to Disabled.
28 Example: Configuring zoned SAS storage enclosures
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 85 86

Comentarios a estos manuales

Sin comentarios