d. Verify that:
the Status of the target system (System2) is ready
the Status of all sending links is Up
the Role of the synchronizing volume groups is Secondary-Rev
the SyncStatus of all volumes in the Secondary-Rev volume groups is Synced
For example, the showrcopy output on System1 looks like:
# showrcopy
Remote Copy System Information
Status: Started, Normal
Target Information
Name ID Type Status Options Policy
System2 11 IP ready mirror_config
System3 12 IP ready mirror_config
Link Information
Target Node Address Status Options
System2 0 10.100.33.61 Up
System2 1 10.101.33.61 Up
System3 0 10.100.33.11 Up
System3 1 10.101.33.11 Up
receive 0 10.100.33.61 Up
receive 1 10.101.33.61 Up
Group Information
Name Target Status Role Mode Options
periodic_group_1 System2 Started Secondary-Rev Periodic Last-Sync Thu Dec 14 18:19:17 PST
2006 , over_per_alert
LocalVV ID RemoteVV ID SyncStatus LastSyncTime
localvv.0 413 remotevv.0 21 Syncing Thu Dec 14 18:40:14 PST 2006
localvv.1 414 remotevv.1 22 Syncing Thu Dec 14 18:39:03 PST 2006
Name Target Status Role Mode Options
periodic_group_2 System3 Started Primary Periodic over_per_alert
LocalVV ID RemoteVV ID SyncStatus LastSyncTime
localvv.2 23 remotevv.0 385 Syncing NA
localvv.3 24 remotevv.1 386 Syncing NA
SolutionProblem
If I/O to the volumes on the
failover system did not stop
before the synchronization:
1. Stop I/O.
2. Manually synchronize the Remote Copy pair. On the failover system (System1),
enter either:
syncrcopy <group_name>
<group_name> - Reversed volume group (for example,
periodic_group_1.r96)
or:
syncrcopy -pat <pattern>
-pat <pattern> - Pattern of reversed volume group names (for example,
periodic*)
130 Disaster Recovery for 1-to-N Configurations