Hp SAN Manual de usuario Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 59
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
SMI-S Access failures
While collecting data through SMI-S for Brocade switches, if there are any connection failures to
the switches or if the SMI agent is stopped, then the data collection falls back to SNMP, and a
report is generated.
For more information, contact HP or visit Servers & Storage expertise center at: http://www.hp.com/
sbso/serverstorage/index.html
Changing SNMP proxy settings for HP Storage 8/20q and QLogic FC
switches
To change the SNMP proxy setting parameter for HP Storage 8/20q and QLogic FC switches,
complete the following steps:
1. Login to the switch you want to change the SNMP proxy settings.
2. Run the admin start command to start the session in admin mode.
3. Run the following command: set setup snmp.
4. Set the SNMP proxy parameter (ProxyEnabled) to "False.
5. Save and exit from the session.
SMI-S Access failures 53
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 59

Comentarios a estos manuales

Sin comentarios