Hp StorageWorks 1000 Modular Smart Array Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Controller Display Messages
57MSA1000 Controller User Guide
407 STORAGE BOX
#<n> OVERHEATED
Error The temperature sensor in
the storage enclosure
indicates that the enclosure
has exceeded the safe
operating range.
The MSA1000 should be
powered off as soon as
possible and immediately
after that, the enclosure
should be powered off, to
avoid hardware failure.
Check all fans and insure
they are operating. Any
failed fans should be
replaced. Insure that there
are drive blank cartridges
in any empty drive bays in
the enclosure. If the
enclosure is an MSA1000
and only one array
controller is inserted, insure
that there are cover plates
installed in the empty array
controller bay and the fibre
bay in the chassis.
408 STORAGE BOX
#<n> POWER
SUPPLY OK
Informational The specified storage
enclosure indicates that one
of its power supplies which
previously had been failed
is now operating normally.
409 STORAGE BOX
#<n> POWER
SUPPLY FAILED
Error The specified storage
enclosure indicates that one
of its power supplies has
failed.
Check all power supplies
and insure they are
operating. Any failed
power supplies should be
replaced.
410 STORAGE BOX
#<n> POWER
SUPPLY ADDED
Informational The specified storage
enclosure indicates that a
power supply has been
added.
411 STORAGE BOX
#<n> POWER
SUPPLY REMOVED
Informational The specified storage
enclosure indicates that a
power supply has been
removed.
Table 3: LCD Message Descriptions
Message Type Description Action
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 71 72

Comentarios a estos manuales

Sin comentarios