Uso de la CLI
41
HP StorageWorks Modular Smart Array 1000/1500 Interfaz de línea de comandos - Guía de usuario
Comando y respuesta de ejemplo
CLI> set auto_path_change disable
Implicit (automatic load-based) LUN ownership changes are currently
DISABLED.
CLI> set auto_path_change enable
Implicit (automatic load-based) LUN ownership changes are currently
ENABLED.
Implicit LUN ownership change preferences are as follows:
Minimum % of proxied requests to trigger implicit path change..: 75%
Minimum number of requests to LUN before path change enabled...: 65536
Minimum time to wait before changing ownership after power-up..: 30 minutes
Minimum time between ownership changes for LUN.................: 30
minutes
CLI> set auto_path_change twp=15
Implicit (automatic load-based) LUN ownership changes are currently
ENABLED.
Implicit LUN ownership change preferences are as follows:
Minimum % of proxied requests to trigger implicit path change..: 75%
Minimum number of requests to LUN before path change enabled...: 65536
Minimum time to wait before changing ownership after power-up..: 15 minutes
Minimum time between ownership changes for LUN.................: 30
minutes