Hp StorageWorks 2.12 Edge Switch Manual de usuario Pagina 130

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 246
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 129
Configuring the Switch
130 Edge Switch Element Manager User Guide
7. Enter the IP address for a trap recipient (SNMP management station) by
clicking in the Trap Recipient column and entering an IP address.
Note: In most cases, step 8 is not necessary. If you do not wish to override the default
UDP number, skip to step 9.
8. Enter user datagram protocol (UDP) port numbers in the UDP Port Number
column. You can override the default UDP port number of 162 with any legal
UDP port number (1 to 65535).
9. Click Activate to activate the data and close the dialog box.
The SNMP configuration is stored in NV-RAM on the switch.
10. If you are finished configuring the switch, back up the configuration data. For
more information, see “Backup and Restore Configuration” on page 168.
Configuring Open Systems Management Server
Edge Switch 2/32 only. For complete procedures on configuring this optional
feature, see “Open Systems Management Server” on page 177.
Configuring FICON Management Server
Edge Switch 2/32 only. For complete procedures on configuring this optional
feature, see “Configuring the FICON Management Server” on page 174.