Hp StorageWorks All-in-One SB600c Storage Blade Manual de usuario

Busca en linea o descarga Manual de usuario para Almacenamiento Hp StorageWorks All-in-One SB600c Storage Blade. HP StorageWorks All-in-One SB600c Storage Blade User Manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - HP StorageWorks

HP StorageWorks All-in-One SB600c Storage Blade Solution user guide 452693001 Part number: 452693–00 1 First edition: September 2007

Pagina 2

To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions bec om e the prop

Pagina 3 - Contents

1 Setup In this section: • Shipping carton contents • Installing an HP BladeSystem c-Class enclosure • Installation guidelines • Installing the HP

Pagina 4

Figure 1 c7000 Enclosure half-height device bay numbering HP BladeSystem c3000 Enclosure The colors correspond to a par tner bay; for example 1 and 2

Pagina 5 - Figures

HP AiO S B600c Server and Storage Blades SB600c server and storage blades support each other in partner bays. Each partner bay will hold one server b

Pagina 6

3. Open the locking clip at the bottom of the front panel of the storage blade. 4. Install the storage blade by inserting it fully into one of the t

Pagina 7

5. Remove a second blank from the adjacent partner bay. 6. Remove the enclosure connector cover from the server blade and the Product Licenses Agree

Pagina 8 - Rack stability

7. Open the locking clip on the left side of the server blade. 8. Install the server blade by inserting it fully into the device bay and closing the

Pagina 9 - Documentation feedback

Installing interconnect modules For specific steps to install interconnect modules, see the documentation that ships with the interconnect module. Inte

Pagina 10 - About this guide

Table 2 Interconnect bay numbering and device mapping c7000 Blade enclosure Server blade signal Interconnect bay Interconnect bay labels NIC 1 (Embe

Pagina 11 - 1 Setup

2Operations In this section: • Powering up the HP All-in-One SB600c Storage B la de Solution • Powering down the HP All-in-One SB600c Storage Blade

Pagina 12 - Installation guidelines

Legal and notice information © Copyright 20 07 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

Pagina 13

IMPORTANT: When the server blade is in standby m ode, auxiliary power is still being provided. To remove all power from the ser ver blade, remove the

Pagina 14

5. Remove the ser ver blade from the chassis. 6. Place the server b lade on a flat, level work surface. WARNING! To reduce the risk of personal injur

Pagina 15

CAUTION: To prevent damage to electrical c omponents, properly ground the server blade before beginning any installation procedure. Improper groundin

Pagina 16 - 16 Se t up

3 Hardware Options installation and cabling In this section •Introduction • Processor option •Memory options •Cabling Introduction The following give

Pagina 17

CAUTION:To prevent possible server malfunction and damage to the equipment, multiprocessor configurations mustcontain processors with the same part num

Pagina 18

6. Remove the front panel/hard drive cage assembly.7. Remove the heatsink blank. Retain the heatsink blank for future use.All-in-One SB600c Storage Bl

Pagina 19 - 2Operations

8. Open the processor retaining latch and the processor socket retaining bracket.9. Remove the processor socket protective cover.26Hardware O ptions i

Pagina 20 - Manual Power Button

10. If the processor has separated from the installation tool, carefully re-insert the processor in the tool.11 . Align the processor installation too

Pagina 21 - Removing the access panel

12. Press down firmly until the processor installation tool clicks and separates from the processor, andthen remove the processor installation tool.13.

Pagina 22 - Installing the access panel

14. Removethethermalinterfaceprotectivecoverfromtheheatsink.15 . Install the heatsink.IMPORTANT:Be sure the processor remains inside the processor ins

Pagina 23 - Processor option

Contents Aboutthisguide ... 7 Intendedaudience... 7 Relateddocumentation...

Pagina 24

CAUTION:Heatsink retaining screws should be tightened in diagonally opposite pairs (in an "X"pattern).16. Install the front panel/hard drive

Pagina 25

Memory optionsThe H P AiO SB600c Server Blade is configured with 2 GB of memory. The server contains eight FBDIMMslots and the Op erating System can ad

Pagina 26

• Install Type I I mezzanine cards only on mezzanine 2 connector.To install the component:1. Power down the server blade.See 19 for more information.2

Pagina 27

7.Install the server blade. See Installing the HP AiO SB600c Server and Storage Blades on page 13CablingIn this section•UsingthelocalI/Ocable• Connect

Pagina 28

Figure 8 Connec ting with a local KVMTable 4 Local KVM connection com ponentsItemDescription1Monitor2USBmouse3USB keyboard4Local I/O cableAccessing a

Pagina 29 - IMPORTANT:

NOTE:Use a USB hub when connecting a USB diskette drive and/or USB DVD-ROM drive to the server blade.The USB hub provides add itional connections.Figu

Pagina 30

36Hardware Options installation and cabling

Pagina 31 - Memory options

4Configuration utilitiesIn this section•iLO2• System Recovery DVD•Config uration tools•KeepingthesystemcurrentiLO 2iLO 2 is a standard component of P ro

Pagina 32

WARNING!During a recovery process, this DVD overwrites the original OS logical drives. All data on thesedrives will be erased.Two methods are availabl

Pagina 33 - Using the local I/O cable

• Supports online array capacity expansion, logical drive extension, assignment of online spares,and RAID or stripe size migration• Suggests the optim

Pagina 34

USBDVD-ROM ... 38 Configurationtools... 38 Array ConfigurationUtility ...

Pagina 35

40Configuration utilities

Pagina 36

5 TroubleshootingTroubleshooting resourcesThe HP ProLiant Servers Troubleshooting Guide provides simple procedures for resolving commonproblems as wel

Pagina 37 - 4Configuration utilities

Apply the latest firmwareandsoftwareupdatesusingtheHPAll-in-OneServiceReleaseDVD.TheDVDprovides software updates, upgrades, and enhancements for the st

Pagina 38 - Configurati on tools

A A ll-in-One SB600c Storage BladeSolution com ponentsHP All-in-One SB600c Server Blade LEDsFigure 10HP All-in-One SB600c Ser ver Bl a d e LEDsAll-in-

Pagina 39 - Keeping the system current

Table 6 HP All-in- One SB600c Server Blade LEDsItemDescription Status1Hard drive bay 1N/A2Power On/Standby button N/A3Local I/O connector* N/A4Hard dr

Pagina 40 - Configuration utilities

HP All-in-One SB600c Storage Blade LEDsFigure 11 HP All-in- O ne SB600c Storage Blade LEDsTable 7 HP All-in-One SB600c Storage Blade LEDsItemDescripti

Pagina 41 - 5 Troubleshooting

SAS and SA TA componentsFigure 12 SAS and SATA device numbersFigure 13 SAS and SATA hard drive LEDsTable 8 SAS and SATA hard drive LEDsItemDescription

Pagina 42 - Troubleshooting

Table9SASandSATAharddriveLEDcombinationsOnline/activityLED (green)Fault/UID LED(amber/blue)InterpretationOn,off,orflashingAlternating amberand blueThe

Pagina 43 - Solution com ponents

System board componentsFigure 14 System board componentsTable 10 System board com p onentsItemDescription1System board thumbscrew2Processor socket 23P

Pagina 44 - Description Status

Table 11 FBD I MM slot numberingFBDI MM slots Mem ory bank Mem ory branch1and3A05and7B12and4C06and8D1Mezzanine connector definitionsTable 12 Mezzanine

Pagina 45

1..2..3..4..5..6..7..8..9..10..11..12..13..14..Figures c7000Enclosurehalf-heightdevicebaynumbering... 12 c3000Enclosurehalf-heightdevic

Pagina 46 - SAS and SA TA components

50All-in-One SB600c Storage Blade Solution components

Pagina 47

B Regulatory Compliance Noticesand S afetyIn this section• Regulatory compliance identification numbers• Federal Communications Commission notice• Decl

Pagina 48 - System board components

Class A EquipmentThis equipment has been tested and found to c omply with the limits for a Class A digital d evice, pursuantto Part 15 of the FCC Rule

Pagina 49 - System maintenance switches

Canadian notice(Avis Canadien)Class A equipmentThis Class A digital apparatus meets all requirements of the Canadian Interference-Causing EquipmentReg

Pagina 50

Japanese noticeBSMI noticeKorean noticeClass A equipmentClass B eq uipment54Regulatory Compliance Notices and Safety

Pagina 51 - FCC rating label

Laser complianceThis product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiberoptic transceiver. Each of these dev

Pagina 52 - Modifications

Preventing electrostatic dischargeTo prevent damaging the system, be aware of the precautions you need to follow when setting up thesystem or handling

Pagina 53 - (Avis Canadien)

Environmental specificationsTable 16 Environmental specification sSpecificationValueTemperature range*Operating 10°Cto35°C(50°F to 95°F)Shipping-40°C to

Pagina 54 - Korean notice

58Regulatory Compliance Notices and Safety

Pagina 55 - Battery replacement notice

In dexAaccess panel,21,22audience,7Bbatteries, replacing,55battery,48,55battery replacement notice,55BSMI notice,54Ccables,52cabling,33Canadian notice

Pagina 56

1..2..3..4..5..6..7..8..9..10..11..12..13..14..15..16..Tables Documentconventions ... 8 Interconnect bay numbering and devi

Pagina 57 - Environmental specifications

Rrack stabilitywarning,8regulatory compliance notices,53related documentation,7removing the access panel,21removing the server blade,20Sseries number,

Pagina 58

About this guide This guide provides information about: • All-in-One SB600c Storage Blade Solution Intended audience HP assumes you are qualified in t

Pagina 59

Document conventions and symbols Table 1 Document conventions Convention Element Blue text: Table 1 Cross-reference links and e-mail addresses Blue,

Pagina 60

WARNING! To reduce the risk of personal injury or damage to equipment: • Extend leveling jacks to the floor. • Ensure that the full weight of the rac

Comentarios a estos manuales