Hp StorageWorks Scalable File Share Manual de usuario

Busca en linea o descarga Manual de usuario para Almacenamiento Hp StorageWorks Scalable File Share. HP StorageWorks Scalable File Share User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 58
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP Scalable File Share User's Guide
G3.0-0
HP Part Number: SFSUGG3-D
Published: December 2008
Edition: 1
Vista de pagina 0
1 2 3 4 5 6 ... 57 58

Indice de contenidos

Pagina 1 - Edition: 1

HP Scalable File Share User's GuideG3.0-0HP Part Number: SFSUGG3-DPublished: December 2008Edition: 1

Pagina 3 - Table of Contents

1 What's In This Version1.1 About This ProductHP SFS G3.0-0 uses the Lustre File System on MSA2000fc hardware to provide a storage systemfor stan

Pagina 4 - 4 Table of Contents

• Keyboard, video, and mouse (KVM) switch• TFT console displayAll of the DL380 G5 file system servers must have their eth0 Ethernet interfaces connect

Pagina 5 - List of Figures

Figure 1-2 MDS and Administration ServerFigure 1-2 shows a block diagram of an MDS server and an administration server with twoMSA2000fc enclosures. T

Pagina 6 - List of Tables

Figure 1-3 OSS ServerFigure 1-3 shows a block diagram of a pair of OSS servers with two HP MSA2000fc enclosures.1.3.1.1 Fibre Channel Switch ZoningIf

Pagina 7 - About This Document

2 Installing and Configuring MSA2000fc ArraysThis chapter provides a summary of steps to install and configure MSA2000fc arrays for use inHP SFS G3.0-

Pagina 8 - Related Information

2.3.2 Creating New VolumesTo create new volumes on a set of MSA2000 arrays, follow these steps:1. Power on all the MSA2000 shelves.2. Define an alias.

Pagina 9 - HP Encourages Your Comments

# forostmsas create vdisk level raid6 disks 16-26 spare \27 vdisk2 ; doneNOTE: For MGS and MDS nodes, HP SFS uses RAID10. An example MSA2000 CLIcomman

Pagina 11 - 1 What's In This Version

3 Installing and Configuring HP SFS Software on ServerNodesThis chapter provides information about installing and configuring HP SFS G3.0-0 Software o

Pagina 12

© Copyright 2008 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Pagina 13

For the minimum firmware versions supported, see Table 3-1.Upgrade the firmware versions, if necessary. You can download firmware from the HP ITResour

Pagina 14

• Provide root password information.These edits must be made, or the Kickstart process will halt, prompt for input, and/or fail.There are also some op

Pagina 15 - 2.1 Installation

## Template ADD bootloader --location=mbr --driveorder=%{ks_harddrive} ## Template ADD ignoredisk --drives=%{ks_ignoredisk} ## Template ADD clearpart

Pagina 16 - 2.3.2 Creating New Volumes

On another system, if it has not already been done, you must create and mount a Linux filesystem on the thumb drive. After you insert the thumb drive

Pagina 17

%{nfs_server} must be replaced by the installation NFS server address or FQDN.%{nfs_iso_path} must be replaced by the NFS path to the RHEL5U2 ISO dire

Pagina 18

HOSTNAME=mynode13.5.2 Creating the /etc/hosts fileCreate an /etc/hosts file with the names and IP addresses of all the Ethernet interfaces oneach syst

Pagina 20 - 3.2 Installation Requirements

4 Installing and Configuring HP SFS Software on ClientNodesThis chapter provides information about installing and configuring HP SFS G3.0-0 Software o

Pagina 21

NOTE: The network address shown above is the InfiniBand IPoIB ib0 interface for the HPSFS G3.0-0 Management Server (MGS) node, which must be accessibl

Pagina 22 - 3.3 Installation Phase 1

• kernel-source-xxx RPM to go with the installed kernel1. Install the Lustre source RPM as provided on the HP SFS G3.0-0 Software tarball in the/opt/h

Pagina 23 - 3.3 Installation Phase 1 23

Table of ContentsAbout This Document...7Intended

Pagina 25 - 3.5.4 Configuring ntp

5 Using HP SFS SoftwareThis chapter provides information about creating, configuring, and using the file system.5.1 Creating a Lustre File SystemThe f

Pagina 26

mpath5 (3600c0ff000d5455bc8c95f4801000000) dm-3 HP,MSA2212fc [size=4.1T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=50][active]

Pagina 27 - 4.2 Installation Instructions

how Heartbeat is configured. Manual fail back can prevent system oscillation if, for example, abad node reboots continuously.Heartbeat nodes send mess

Pagina 28

NOTE: The gen_hb_config_files.pl scripts only works if the host names in the /etc/hosts file appear with the plain node name first, as follows:192.168

Pagina 29

It is possible to generate the simple files ha.cf, haresources, and authkeys by hand ifnecessary. One set of ha.cf with haresources is needed for each

Pagina 30

5.2.3.2 Editing cib.xmlThe haresources2cib.py script places a number of default values in the cib.xml file thatare unsuitable for HP SFS G3.0-0.• By d

Pagina 31 - 5 Using HP SFS Software

10 Resources configured.============Node: n4 (0236b688-3bb7-458a-839b-c19a69d75afa): onlineNode: n3 (48610537-c58e-48c5-ae4c-ae44d56527c6): onlineFile

Pagina 32 - 5.2 Configuring Heartbeat

• Heartbeat uses iLO for STONITH I/O fencing. If a Heartbeat configuration has two nodesin a failover pair, Heartbeat would like both of those nodes t

Pagina 33 - 5.2.1 Preparing Heartbeat

5.5 Testing Your ConfigurationThe best way to sanity test your Lustre file system is to perform normal file system operations,such as normal Linux fil

Pagina 34 - 5.2.3 Configuration Files

5 Using HP SFS Software...315.1 Creating a Lustre File Sy

Pagina 35 - 5.2 Configuring Heartbeat 35

13 UP osc hpcsfsc-OST0004-osc hpcsfsc-mdtlov_UUID 5 14 UP osc hpcsfsc-OST0006-osc hpcsfsc-mdtlov_UUID 5 15 UP osc hpcsfsc-OST0007-osc hpcsfsc-mdtlov_U

Pagina 36 - 5.2.5 Starting Heartbeat

Run this command on each server node for all the mpaths which that node normally mounts.4. chkconfig heartbeat off on all server nodes and reboot them

Pagina 37 - 5.2.9 Things to Note

Also see man collectl.42 Using HP SFS Software

Pagina 38 - 5.4 Stopping the File System

6 Licensing InformationWhen you ordered the licenses for your HP SFS G3.0-0 system, you received letters with the titleLicense-To-Use from HP. There w

Pagina 40 - 40 Using HP SFS Software

7 Known Issues and WorkaroundsThe following items are known issues and workarounds.7.1 Server RebootAfter the server reboots, it checks the file syste

Pagina 41 - 5.5.1.2 On the Client

4. Manually mount mgs on the MGS node:# mount /mnt/mgs5. Manually mount mds on the MDS node:# mount /mnt/mdsIn the MDS /var/log/messages file, look fo

Pagina 42 - Also see man collectl

A HP SFS G3.0-0 PerformanceA.1 Benchmark PlatformHP SFS G3.0-0, based on Lustre File System Software, is designed to provide the performanceand scalab

Pagina 43 - 6 Licensing Information

The Lustre servers were DL380 G5s with two quad-core processors and 16GB of memory, runningRHEL v5.1. These servers were configured in failover pairs

Pagina 44

Figure A-3 shows single stream performance for a single process writing and then reading asingle 8GB file. The file was written in a directory with a

Pagina 45 - 7.4 MDS Is Unresponsive

List of Figures1-1 Platform Overview...

Pagina 46

The test shown in Figure A-5 did not use direct I/O. Nevertheless, it shows the cost of client cachemanagement on throughput. In this test, two proces

Pagina 47 - A HP SFS G3.0-0 Performance

Figure A-6 Multi-Client Throughput ScalingIn general, Lustre scales quite well with additional OSS servers if the workload is evenlydistributed over t

Pagina 48 - A.2 Single Client Performance

A.4 One Shared FileFrequently in HPC clusters, a number of clients share one file either for read or for write. Forexample, each of N clients could wr

Pagina 49

Another way to measure throughput is to only average over the time while all the clients areactive. This is represented by the taller, narrower box in

Pagina 50 - A.3 Throughput Scaling

For workloads that require a lot of disk head movement relative to the amount of data moved,SAS disk drives provide a significant performance benefit.

Pagina 51 - A.3 Throughput Scaling 51

IndexSymbols/etc/hosts fileconfiguring, 25Bbenchmark platform, 47Ccache limit, 50cib.xml file, 35CLI, 15collectl, 41configuration instructions, 24conf

Pagina 52 - A.4 One Shared File

stonewalling, 52stonith, 33supportHP support, 8Tthroughput scaling, 50thumb drive, 22Uupgradingclients, 29servers, 11user accessconfiguring, 25Vvolume

Pagina 55

List of Tables1-1 Supported Configurations ...

Pagina 56 - 56 Index

About This DocumentThis document provides installation and configuration information for HP Scalable File Share(SFS) G3.0-0. Overviews of installing a

Pagina 57

WARNING A warning calls attention to important information that if notunderstood or followed will result in personal injury ornonrecoverable system pr

Pagina 58

• HP StorageWorks Scalable File Share for SFS20 Enclosure Hardware Installation Guide Version 2.2at:http://docs.hp.com/en/8958/HP_StorageWorks_SFS_SFS

Comentarios a estos manuales

Sin comentarios