Specifiable val-
ues
(default)
DescriptionParameter
0 to 3600
(Value of
RETRY_TIME)
Specifies the maximum number of times a retry
can be performed for checking whether pair
splitting has finished.
Specify this parameter to check the pair status
after pairsplit is executed for backup or
restoration.
If you specify 0, Application Agent continues
to retry checking until it succeeds in checking
the status.
When adding this parameter, make sure that
the product of the SPLIT_RETRY_TIME-value and
SPLIT_RETRY_WAIT-value is sufficiently larger
than the time required to complete pair splitting.
SPLIT_RETRY_TIME
0 to 360000
(Value of
RETRY_WAIT)
Specifies the retry interval for checking whether
pair splitting has finished. You can specify a
value in units of 10 milliseconds.
Specify this parameter to check the pair status
after pairsplit is executed for backup or
restoration.
When adding this parameter, you must
consider the following: the number of disks to
be backed up or restored, the disk sizes, and
the difference in data amount produced during
I/O operations in online backup processing
#2
.
Generally the required time of the
resynchronization processing is larger than that
of the splitting processing, specify
RESYNC_RETRY_WAIT >
SPLIT_RETRY_WAIT for the value.
SPLIT_RETRY_WAIT
0 to 3600
(Value of
RETRY_TIME)
Specifies the maximum number of times a retry
can be performed for checking whether
resynchronization on restoration has finished.
If you specify 0, Application Agent continues
to retry checking until it succeeds in checking
the pair status.
When adding this parameter, make sure that
the product of the RESTORE_RETRY_TIME-value
and RESTORE_RETRY_WAIT-value is sufficiently
larger than the time required to complete
resynchronization.
RESTORE_RETRY_TIME
Preparation for using Application Agent120