Hp PROCURVE 2610 Manual de usuario Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 112
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
A-2
Switch Specifications
Switch Specifications
RPS/EPS Electrical Input
Environmental
* The operating maximum altitude should not exceed that of any accessory being connected
to any switch in the 2610 series.
BTU Ratings
2610 Non-PWR Series
Input voltage Maximum current
RPS Input
+12 VDC 7.5A
EPS Input
N/A N/A
2610-PWR Series
Input voltage Maximum current
RPS Input
+12 VDC 7.5A
EPS Input
-50 VDC 16A
2610 Switches Operating Non-Operating
Temperature 0°C to 50°C (32°F to 122°F) -40°C to 70°C (-40°F to 158°F)
Relative humidity
(non-condensing)
15% to 95% at 40°C (104°F) 15% to 90% at 65°C (149°F)
Maximum altitude 3.0 Km (10,000 ft)* 4.6 Km (15,000 ft)
Switch Model Combined BTU
1
Switch only BTU
2610-24/12PWR 827 181
2610-24-PWR 2281 410
2610-48-PWR 2281 410
2610-24 Non-PoE 142
2610-48 Non-PoE 285
1
Includes switch and maximum number of PoE powered devices
connected to the switch at 15.4 watts.