Installation and Use with the Tru64Unix Operating System 1-9
5.0 Reconfiguring iCAP
If you accidentally put a CPU on line using the "Manage CPUs" task or include
an erroneous set of CPUs, you can reconfigure iCAP to put the incorrect CPUs
off line and to include only the CPUs you want. Use the /usr/sbin/codconfig -
show command to display the list of currently configured CPUs and then use
the /usr/sbin/codconfig cpu_id_list command to reconfigure iCAP.
The following example describes how to reconfigure iCAP when a CPU is added
accidentally to the iCAP configuration list.
3. Display the list of currently configured CPUs:
# /usr/sbin/codconfig –show
Compaq Capacity on Demand (CCoD) is currently configured.
The following CPUs are CCoD spares and can be purchased or
loaned to the system:
1 2 3 6
4. Re-enter the correct list of configured CPUs
Continuing with the example, reconfigure iCAP without CPU 6:
# /usr/sbin/codconfig 1 2 3
6.0 Changing System Configuration
When you reinstall or update the operating system or hardware configuration of
a system that previously has been configured with iCAP, you may need to
reinstall, reconfigure, or both.
6.1 New Installation
A complete installation of Tru64 UNIX will overwrite the previously installed
iCAP software. You must reinstall and reinitialize the iCAP software once the
operating system installation is complete.
6.2 Update Installation
You should remove the iCAP software prior to performing an Update
Installation and then reinstall it using the version of iCAP appropriate for the
new operating system version.