VCEM validates the following components when adding a VC Domain to a VC Domain group,
therefore the VC Domain configuration must be identical to the VC Domain Group configuration.
Verify that the following components are identical:
• Interconnect bays location and model
• Enclosure model
• Domain settings:
Configuration for double density servers (for example, BL2x220c)◦
◦ Configuration for full-height and half-height single density servers (for example, BL460c,
BL480c)
• Network Access Groups
◦ Name(s) and networks
• Ethernet and iSCSI Flex-10 settings:
◦ MAC Cache Failover:
Enable Fast MAC Cache Failover–
– MAC Refresh Interval
◦ IGMP Snooping:
Enable IGMP Snooping–
– IGMP Idle Timeout Interval
◦ Server VLAN Tagging support:
Tunnel VLAN Taggings or Map VLAN Taggings–
– Force Server connection setting
◦ Multiple Network Speeding Settings:
Preferred Link Connections–
– Preferred Link Connection Speed
– Maximum Link Connection
– Maximum Link Connection Speed
◦ Network SNMP settings:
Read Community–
– System Contact
– IP addresses
◦ Port Throughput Statistics
◦ VLAN Capacity
– Legacy VLAN capacity or Expanded VLAN capacity
• Fibre Channel SAN Fabric settings:
Enables SMI-S◦
◦ Fibre Channel SNMP settings: Read Community, System Contact, and IP addresses
• Network and Fibre Channel SAN Fabrics uplinks
32 Managing VC Domains