Hp PCIe IO Accelerators for ProLiant Servers Manual de usuario

Busca en linea o descarga Manual de usuario para Accesorios De Computador Hp PCIe IO Accelerators for ProLiant Servers. HP PCIe IO Accelerators for ProLiant Servers User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 130
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - User Guide

HP PCIe IO Accelerator for ProLiant Servers User Guide Part Number 607720-002 November 2010 (Second Edition)

Pagina 2 - Intended audience

Introduction 10 Supported firmware revisions Release Firmware revision 1.2.4 17350 1.2.7 36867 or 42014 1.2.8.4 43246 2.2 43674 Supported ha

Pagina 3 - Contents

Utilities 100 fio-trim-config Description Enables or disables the Trim feature (Windows® service), which reclaims available space from the file syst

Pagina 4 - Contents 4

Utilities 101 • -s: Updates the devices in the specified slots using ‘*’ as a wildcard for devices. The slots are identified in the following PCIe

Pagina 5 - Contents 5

Monitoring IO Accelerator health 102 Monitoring IO Accelerator health NAND flash and component failure The IO Accelerator is a highly fault-tolerant

Pagina 6 - Contents 6

Monitoring IO Accelerator health 103 HP 160GB SLC PCIe ioDrive for ProLiant Servers, Product Number:600278-B21 ... Media status: Healthy; Reserves:

Pagina 7 - About this guide

Monitoring IO Accelerator health 104 heavy workload is evicted from a RAID group for failure to receive data at a sufficient rate. A drive in read-o

Pagina 8 - Introduction

Trim support (Windows only) 105 Trim support (Windows only) Introduction to Trim Trim is used to address a unique property of solid state drives. Th

Pagina 9 - Packing list

Trim support (Windows only) 106 Starting and stopping Trim To globally start or stop the Trim service through the IO Accelerator Management Tool, in

Pagina 10 - Supported hardware

Trim support (Windows only) 107 BitmapRetrievalDelayInMilliseconds This value affects how much impact Trim has on the CPU. The default is 25 millise

Pagina 11 - Introduction 11

Using Windows page files with the IO Accelerator 108 Using Windows page files with the IO Accelerator Introduction to Windows page files This sectio

Pagina 12 - Hardware installation

Using Windows page files with the IO Accelerator 109 • it minimizes overall host memory consumption. On Windows® operating systems, NTFS will gener

Pagina 13 - Hardware installation 13

Introduction 11 * The fio-format utility automatically formats the device to this block size unless specified differently. You can reduce memory use

Pagina 14 - PCIe slot

Using Windows page files with the IO Accelerator 110 To query the current value, run this command: fio-config -g FIO_PREALLOCATE_MEMORY An alternate

Pagina 15

Using Windows page files with the IO Accelerator 111 page 109)" to properly enable page file support on one or more IO Accelerators. System

Pagina 16 - Hardware installation 16

Using Windows page files with the IO Accelerator 112 • Main Article Link: Pushing the Limits of Windows (http://blogs.technet.com/b/markrussinovich

Pagina 17 - Hardware installation 17

Resources 113 Resources Subscription service HP recommends that you register your product at the Subscriber’s Choice for Business website at www.hp.

Pagina 18

Technical support 114 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical s

Pagina 19 - Hardware installation 19

Technical support 115 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howe

Pagina 20

Technical support 116 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'information

Pagina 21 - Linux environments

Technical support 117 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das

Pagina 22

Technical support 118 el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de comp

Pagina 23

Technical support 119 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente

Pagina 24 - Setting the driver options

Hardware installation 12 Hardware installation Installing the HP PCIe IO Accelerator WARNING: To reduce the risk of personal injury or damage to

Pagina 27 - Disabling the driver

Regulatory compliance notices 122 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory complianc

Pagina 28

Regulatory compliance notices 123 Disposal of waste equipment by users in private households in the European Union This symbol on the product or

Pagina 29

Acronyms and abbreviations 124 Acronyms and abbreviations CIM common information model CIMOM common information model object manager CMPI common m

Pagina 30 - Configuring RAID for Linux

Acronyms and abbreviations 125 GUID globally unique identifier HBA host bus adapter I/O input/output IOPS input/output operations per second iSC

Pagina 31 - RAID 10

Acronyms and abbreviations 126 RAID redundant array of inexpensive (or independent) disks RAM random access memory RFC request for comments RHEL

Pagina 32 - Setting up SNMP for Linux

Acronyms and abbreviations 127 USB universal serial bus VM Virtual Machine VSL virtual storage layer WBEM Web-Based Enterprise Management WMI Wi

Pagina 33 - SNMP agentx subagent

Index 128 A About this guide 7 Adding a file system 50 Attach Device 82 attaching mixed attached/detached devices 83 authorized reseller 1

Pagina 34 - Enabling SNMP test mode

Index 129 HP Subscriber's Choice for Business 112 HP technical support 113 HP, contacting 113 I identification number 121 installing ES

Pagina 35 - Linux environments 35

Hardware installation 13 6. If applicable, remove the cover slot.

Pagina 36 - Linux environments 36

Index 130 SNMP master agent 32 SNMP MIB support 37, 53 SNMP, Linux details 32 SNMP, Windows details 51 software installation 39, 65 softwa

Pagina 37 - Troubleshooting SNMP

Hardware installation 14 7. Grasp the PCIe IO Accelerator by the top edge and insert it gently, but firmly, into the available PCIe slot.

Pagina 38 - Linux environments 38

Hardware installation 15 8. Secure the PCIe IO Accelerator retaining bracket using a screw or lever (depending on how your hardware is configured).

Pagina 39 - Linux environments 39

Hardware installation 16 1. Locate the half-height bracket in your PCIe IO Accelerator package. CAUTION: Use care when removing the retaining s

Pagina 40 - Windows Server environments

Hardware installation 17 4. Align the LEDs on the PCIe IO Accelerator with the holes in the half-height bracket. Be sure the bracket tabs are on the

Pagina 41 - Using the Setup Wizard

Hardware installation 18 CAUTION: Do not overly tighten screws. Overly tightening the screws might damage the device. 6. Return to "Instal

Pagina 42

Hardware installation 19 6. Grasp the Duo by the top edge and seat it in the available PCIe slot.

Pagina 43

© Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Pagina 44

Hardware installation 20 7. Secure the Duo retaining bracket using a screw or lever (depending on how your hardware is configured). 8. If you are

Pagina 45

Linux environments 21 Linux environments Linux installation requirements The HP-provided Linux installers for the IO Accelerator do not contain bina

Pagina 46

Linux environments 22 • SMH webpage: hp_ioaccelerator_system_management_homepage_web_templates To install the IO Accelerator software: 1. If you a

Pagina 47

Linux environments 23 Example: bash hp_io_accelerator-2.2.0.60.4-rhel5.run 8. If the dialog package is installed on your server, the installer scr

Pagina 48 - Performing the upgrade

Linux environments 24 The following is an example output showing that the system recognizes the IO Accelerator: Found 1 ioDrive in this system Fusio

Pagina 49

Linux environments 25 Module parameter Default (min/max) Description force_minimal_mode False Force minimal mode on the device. parallel_attach T

Pagina 50 - IO Accelerator naming

Linux environments 26 On systems that use scripts to load drivers, you can enable or disable an init script with the standard init script utility, c

Pagina 51

Linux environments 27 3. With the blacklist command in place, reboot Linux. The IO Accelerator driver does not load. To restore driver auto-loading

Pagina 52

Linux environments 28 shutdown -h now IMPORTANT: For the firmware upgrade to write to the device properly, you must completely shut down the sy

Pagina 53

Linux environments 29 iv. If the HP IO Accelerator Management Tool is installed, uninstall it. o To uninstall 2.x driver, run the following command

Pagina 54 - • cpqIoDimmInfoStatus

Contents 3 Contents About this guide ...

Pagina 55

Linux environments 30 # rpm -e iomemory-vsl-2.6.18-194.el5-2.2.0.82-1.0 To install the new driver, see "Downloading and installing the driver a

Pagina 56 - Using installation logs

Linux environments 31 RAID0/Striped To create a striped set where fioa and fiob are the two IO Accelerators you want to stripe, enter the following

Pagina 57 - Creating an installation log

Linux environments 32 Setting up SNMP for Linux Use the following procedures to set up SNMP for Linux. SNMP details for Linux The fio-snmp-agentx S

Pagina 58 - Creating a patch install log

Linux environments 33 #set the port that the agent listens on (defaults to 161) agentaddress 161 # simple access control (some form of access cont

Pagina 59

Linux environments 34 This command launches the IO Accelerator subagent using the net-snmp configuration file net-snmp. This file must reside in one

Pagina 60 - Message Suggested solution

Linux environments 35 NOTE: For proper operation, the subagent file name must be fio-snmp-agentx.conf. When the SNMP Agentx runs, it reads the f

Pagina 61 - VMWare ESX environments

Linux environments 36 The SNMP Agentx now replaces any existing IO Accelerator driver data it has with any populated fields in the list of parameter

Pagina 62

Linux environments 37 ExtnUsedPhysCapacityU = 4 ExtnUsedPhysCapacityL = 782330816 ExtnTotalLogCapacityU = 18 ExtnTotalLogCapacityL = 2690588672

Pagina 63

Linux environments 38 • cpqioDrvInfoStatus • cpqioDrvInfoName • cpqioDrvInfoSerialNumber • cpqioDrvInfoPartNumber • cpqioDrvInfoSubvendorPart

Pagina 64 - VMWare ESX environments 64

Linux environments 39 • cpqioDrvExtnPhysicalBytesWrittenL

Pagina 65 - VMWare ESX environments 65

Contents 4 Manual installation on Windows Server ...

Pagina 66 - Software installation

Windows Server environments 40 Windows Server environments Uninstalling a previously-installed driver CAUTION: Upgrading an IO Accelerator from

Pagina 67 - IO Accelerator management

Windows Server environments 41 4. Run the IO Accelerator installation program (Setup Wizard) as explained in "Using the Setup Wizard (on page 4

Pagina 68

Windows Server environments 42 2. Click Next. The Installation Recommendations screen appears. 3. If you have a previous version of the IO Acceler

Pagina 69 - Performance report

Windows Server environments 43 4. If you want to use the default installation location (C:\Program Files\HP IO Accelerator), click Next. If you want

Pagina 70

Windows Server environments 44 o Device Driver (required for the drive to be recognized in Windows® operating system) o HP IO Accelerator Managemen

Pagina 71 - Device Tree

Windows Server environments 45 7. Click Install to begin installation. When installation is complete, the Completion screen appears. NOTE: You

Pagina 72 - Drive status

Windows Server environments 46 Manual installation on Windows Server 2003 The Windows Driver Wizard automatically detects the new IO Accelerator and

Pagina 73

Windows Server environments 47 Manual installation on Windows Server 2008 The Windows Driver Wizard automatically detects the new IO Accelerator and

Pagina 74

Windows Server environments 48 To discover old firmware: 1. Find the name of the latest firmware version as noted in the Release Notes. 2. Use the

Pagina 75 - Device Report panel

Windows Server environments 49 All three external LED indicators light up during the update process. 5. Restart the computer to finish the firmware

Pagina 76

Contents 5 Device Tree ...

Pagina 77 - Performance monitoring

Windows Server environments 50 5. Restart the computer. 6. Download the latest driver from the HP website (http://www.hp.com/support). 7. Either u

Pagina 78 - Operations

Windows Server environments 51 2. Expand HP StorageWorks IO Accelerators, and then double-click HP StorageWorks IO Accelerator. The Properties dialo

Pagina 79 - Update firmware

Windows Server environments 52 3. After the device is initialized, you can add partitions or volumes. For more information, see the Disk Management

Pagina 80

Windows Server environments 53 For example, you can use the SNMP test mode to change the non-writeable indicator and generate a trap, or simulate a

Pagina 81 - 6. Click Next to proceed

Windows Server environments 54 SNMP test registry entry Description collection. cpqioDrvInfoCurrentTemp* Current temperature of the device in degree

Pagina 82 - Firmware already updated

Windows Server environments 55 • cpqIoDimmInfoName • cpqIoDimmInfoSerialNumber • cpqIoDimmInfoPartNumber • cpqIoDimmInfoSubvendorPartNumber • c

Pagina 83 - Attach Device

Windows Server environments 56 • cpqIoDimmInfoPowerlossProtectDisabled • cpqIoDimmInfoInternalTempHigh • cpqIoDimmInfoAmbientTemp • cpqIoDimmExt

Pagina 84 - Detach Device

Windows Server environments 57 Windows Installer logging options The Windows® Installer handles its installations through Msiexec.exe. The logging

Pagina 85 - Low level format

Windows Server environments 58 When the installation package is included in an .exe bootstrapper, do not use msiexec. in the command line. For examp

Pagina 86

Windows Server environments 59 NOTE: Do not leave this option active because every install or uninstall operation on an .msi file will create a ne

Pagina 87

Contents 6 Using Windows page files with the IO Accelerator ... 108 Introduction

Pagina 88

Windows Server environments 60 Message Suggested solution 2 Select your unattached IO Accelerator from the Device Tree. 3 Click Attach. 4 Confir

Pagina 89 - Maintenance

VMWare ESX environments 61 VMWare ESX environments Creating the ESX IO Accelerator driver CD The IO Accelerator driver is distributed on the VMware

Pagina 90 - Common maintenance tasks

VMWare ESX environments 62 $ vihostupdate <conn_options> --install --nosigcheck --bundle=offline-bundle.zip 7. Restart the ESX host. 8. Exit

Pagina 91 - Enabling auto attach

VMWare ESX environments 63 The firmware and utilities are installed to the following locations Package type Installation location Utilities (ESX o

Pagina 92 - Unmanaged shutdown issues

VMWare ESX environments 64 8. Find the files with those UIDs in /vmfs/devices/disks/. Select the files with appended partition numbers. In this case

Pagina 93 - Utilities

VMWare ESX environments 65 Using the IO Accelerator as swap with ESX HP does not recommend using the IO Accelerator as swap space when using the ESX

Pagina 94 - Utilities 94

HP IO Accelerator Management Tool 66 HP IO Accelerator Management Tool Operating system support The following is the IO Accelerator Management Tool

Pagina 95

HP IO Accelerator Management Tool 67 NOTE: Running the IO Accelerator Management Tool requires administrator privileges. Log in as root or use the

Pagina 96 - • -q: Quit on erase error

HP IO Accelerator Management Tool 68 • The Device Report panel on the right displays details on one or more selected devices.

Pagina 97 - Utilities 97

HP IO Accelerator Management Tool 69 Performance report When you click the Performance tab, IO Accelerator Management Tool draws a real-time graph o

Pagina 98

About this guide 7 About this guide Contents summary • Installing the IO Accelerator • Downloading and installing the approved driver and utilitie

Pagina 99

HP IO Accelerator Management Tool 70 • Page File Settings—Enables or disables the use of the IO Accelerator as a page file device. NOTE: A low

Pagina 100 - Utilities 100

HP IO Accelerator Management Tool 71 • The Ctrl-A key combination selects all the available items in a list (such as all the IO Accelerators in the

Pagina 101 - Utilities 101

HP IO Accelerator Management Tool 72 If you right-click the Tool Tip, the context menu appears. Drive status The tree also shows the status of eac

Pagina 102 - Health monitoring techniques

HP IO Accelerator Management Tool 73 • Drive Normal: When a drive is attached to the operating system and available to users, it appears as Status:

Pagina 103

HP IO Accelerator Management Tool 74 • Drive Detached: When a drive is not available to the operating system or users, it appears as Status: Detach

Pagina 104

HP IO Accelerator Management Tool 75 • Operation in Progress: The device shows an activity icon. A message in the Device Report panel indicates whi

Pagina 105 - Trim support (Windows only)

HP IO Accelerator Management Tool 76 3. Press Ctrl-Click left mouse button to select two or more separate devices. The Device Report panel displays

Pagina 106 - Starting and stopping Trim

HP IO Accelerator Management Tool 77 Saving IO Accelerator information You can save the selected IO Accelerator information using the Copy feature.

Pagina 107 - Trim configurations

HP IO Accelerator Management Tool 78 When you open the Performance tab, it shows a combined view of read and write performance. To view the read and

Pagina 108 - Accelerator

HP IO Accelerator Management Tool 79 • Detach Device—Detaches an IO Accelerator so you can perform a low-level format or upgrade the firmware. Deta

Pagina 109 - Non-paged memory pool

Introduction 8 Introduction Overview Designed around ioMemory, a revolutionary storage architecture, HP PCIe IO Accelerator is an advanced NAND flas

Pagina 110 - Windows page file management

HP IO Accelerator Management Tool 80 To perform a firmware upgrade: 1. Download the IO Accelerator firmware upgrade file from and place it in a co

Pagina 111

HP IO Accelerator Management Tool 81 The IO Accelerator Management Tool shows the default directories, so unless you have installed the firmware in

Pagina 112 - Virtual Memory performance

HP IO Accelerator Management Tool 82 7. Click Next to proceed 8. Click Update. The selected drives display a blue progress bar in the Device Report

Pagina 113 - Resources

HP IO Accelerator Management Tool 83 To cancel the update, click the X at the upper right of the dialog box to exit. To select a different firmware

Pagina 114 - Technical support

HP IO Accelerator Management Tool 84 If the Attach Device operation fails, an error message appears. Attaching mixed attached/detached devices If y

Pagina 115 - Technical support 115

HP IO Accelerator Management Tool 85 Use Attach to restore the operating system access to the IO Accelerator. Detaching mixed attached/detached dev

Pagina 116 - Customer Self Repair

HP IO Accelerator Management Tool 86 o Maximum Write Performance—Formats the device for maximum write performance at the cost of approximately 50% c

Pagina 117 - Technical support 117

HP IO Accelerator Management Tool 87 The IO Accelerator Management Tool automatically detaches the selected devices. A blue progress bar displays in

Pagina 118 - Reparo feito pelo cliente

HP IO Accelerator Management Tool 88 • About IO Accelerator Management Tool: Displays the version splash screen. • Exit: Closes the IO Accelerato

Pagina 119 - Technical support 119

Maintenance 89 Maintenance Maintenance tools The IO Accelerator includes both software utilities to maintain the device and external LED indicators

Pagina 120 - Technical support 120

Introduction 9 IO Accelerator Duo capacity 320GB 640GB 512B packet size) packet size) Access latency 26 μs (read) 29 μs (read) *Performance achi

Pagina 121 - Technical support 121

Maintenance 90 Common maintenance tasks The following tasks are the most common tasks for maintaining your IO Accelerator. NOTE: All commands re

Pagina 122 - • EMC Directive 2004/108/EC

Maintenance 91 For 2.x systems: /etc/modprobe.d/iomemory-vsl.conf 2. Add the following line to that file: o For 1.2.x systems: options iodrive aut

Pagina 123

Maintenance 92 1. Open the IO Accelerator Utilities folder. The default location is C:\Program Files\HP IO Accelerators\Utils\. 2. Double-click the

Pagina 124 - Acronyms and abbreviations

Utilities 93 Utilities Utilities reference The IO Accelerator installation packages include various command line utilities, installed by default to

Pagina 125

Utilities 94 NOTE: To run these utilities from a command line using Windows Server®, you must either change directories to the directory that con

Pagina 126

Utilities 95 • -p Print: Prints the PCI bus ID at <device> to standard output. Usage and error information can be written to standard output

Pagina 127 - Virtual Machine

Utilities 96 Option Default (min/max) Description parallel_attach True Enable parallel attach of multiple drivers fio_preallocate_memory False

Pagina 128 - Index 128

Utilities 97 • %: Percentage of device for user data • t/T: Number of terabytes to format • g/G: Number of gigabytes to format • m/M: Number

Pagina 129 - Index 129

Utilities 98 This utility is an SNMP sub-agent that implements the cpqIODrv.mib for the IO Accelerator driver. The fio-snmp-agentx utility communica

Pagina 130 - Index 130

Utilities 99 • -a: Prints all available information for each device. The following information is reported: o Number and types of boards installe

Comentarios a estos manuales