Service and Technical Reference Guide, xw3100 338611-001 5–17
Removal and Replacement Procedures
8. Push the drive release latch 1 toward the rear of the chassis and hold.
9. Slide the drive 2 toward the front of the drive cage, then lift the drive out of the workstation.
To replace the drive:
1. Install two guide screws in the lower holes on each side of the drive.
Ä
CAUTION: Use only 3/16-inch or 5-mm long screws as guide screws. Longer screws can damage the
internal components of the drive.
When replacing the drive, transfer the four screws from the old drive to the new one. The screws
take the place of drive rails. You will need a Torx T-15 screwdriver to remove and re-install the
guide screws.