Server Blade Component Identification
Table 1-2: Hot-Plug SCSI Hard Drive LED Status Combinations
(1) Activity (2) Online (3) Fault Description
On Off Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
On Flashing Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off Off Off OK to replace the drive online if a predictive failure alert
is received and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on controller
is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off Off On OK to replace the drive online.
The drive has failed and has been placed offline.
continued