Specifications
Environmental specifications
Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Shipping -40°C to 60°C (-40°F to 140°F)
Storage -20°C to 60°C (-4°F to 140°F)
Maximum wet bulb temperature 30°C (86°F)
Relative humidity
(noncondensing)**
Operating 10% to 90%
Shipping 10% to 90%
Storage 10% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70 kPa
(10.1 psia). Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 kPa (4.4 psia).
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
Server blade specifications
Spec
storage corresponds to a pressure minimum of 70 kPa.
ification Value
Heig cm (2.19 in) ht 5.56
Depth 50.95 cm (20.06 in)
Width 18.16 cm (7.15 in)
Weight (maximum) 5.90 kg (13.00 lb)
Weight (no drives installed) 5.33 kg (11.75 lb)
Specifications 77