RAID configuration 30
9. In the Option menu box, select Array Configuration Utility.
10. In the Main Menu
box, select Configure Drives.
11. Select the hard drives you want to include in the RAID setup, then press Enter.
A warning message appears.
12. Type Yes then press Enter.
The selected drives will be configured with array information.
13. After the completing the initial drive configuration, select Create Arrays in the Main Menu
.
14. Select the hard drives you want to include in the array, then press Enter.
15. In the Array Properties box, set the values for the RAID properties.
To view possible options for each property, select a property, then press F1.
a. Select an array type (RAID level).
b. Enter an array label.
c. Select the stripe size.
d. Select the manner of creating the array.
16. Select Done, then press Enter.
The system automatically configures the RAID level, erasing all existing data on the hard drives.
17. Once the configuration process is complete, press Esc to close the HP Embedded SATA Setup Utility.
18. In the Exit Utility prompt, select Yes, then press Enter.
The system will automatically reboot and initialize the created array.