Hp ProLiant DL560 Gen8 Server Manual de usuario Pagina 45

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 44
Hardware options installation 45
a.
Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend the server from the rack (on page 18).
4. Remove the access panel (on page 20).
5. Remove the air baffle (on page 23).
6. Open the DIMM slot latches..
7. Install the DIMM.
8. Install the air baffle (on page 24).
9. Install the access panel (on page 20).
10. Install the server into the rack ("Installing the server into the rack" on page 30).
11. Connect each power cord to the server.
12. Connect each power cord to the power source.
13. Power up the server (on page 18).
Use RBSU ("HP ROM-Based Setup Utility" on page 74) to configure the memory mode.
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LED
combinations (on page 8)."
Hot-plug hard drive options
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
If only one hard drive is used, install it in the bay with the lowest device number.
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Removing a hot-plug SAS or SATA hard drive