Server Component Identification 21
System LED and
Color
Internal Health
LED Color
Status
Processor failure,
socket X (Amber)
Red
Processor in socket X has failed.
Processor in socket X failed over to the offline spare.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
Amber Processor in socket X is in a pre-failure condition.
Processor failure, two
or more sockets
(Amber)
Red Processor types are mismatched.
PPM failure, slot X
(Amber)
Red
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
DIMM failure, slot X
(Amber)
Red
DIMM in slot X has failed.
DIMM in slot X is an unsupported type, and no valid
memory exists in another bank.
Amber
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
DIMM in slot X is an unsupported type, but valid
memory exists in another bank.
Overtemperature
(Amber)
Red
Health Driver has detected a cautionary temperature
level.
Server has detected a hardware critical temperature
level.
Riser interlock
(Amber)
Red PCI riser cage is not seated.
Peripheral board
interlock (Amber)
Red Peripheral board is not seated.
Fan (Amber) Amber Redundant fan has failed.
Red The minimum fan requirements are not being met. One
or more fans have failed or are missing.
HP CONFIDENTIAL