Installing Hardware Options, Hot-Plug
Never turn a disk enclosure off while the initiator or controller is powered
on or active. Doing so can cause the initiator or controller to mark the drives as
failed. This action can result in permanent data loss.
If a drive is replaced while the system is off, it may be necessary to rebuild
the replaced drive. Follow the instructions on the screen or the instructions
outlined in the system reference guide.
CAUTION: Pressing the F2 key will cause permanent data loss to the entire logical
drive. Press the F2 key only if all the drives have been replaced or if complete data
loss is required.
NOTE: When a drive configured for fault tolerance is replaced, the replacement drive
automatically begins restoring after it is installed. When a drive is in the process of being
restored, the Online LED blinks green. The LED continues to flash until the drive is completely
restored.
Removing a Hot-Plug SCSI Hard Disk Drive
To remove a hot-plug SCSI hard disk drive:
1. To remove a hot-plug SCSI hard drive, push the release button on the left of the
drive and rotate the hot-plug drive ejector lever outward to unlock the drive.
2. Pull the drive out of the drive bay.
HP ProLiant DL740 Server User Guide 5-29
HP CONFIDENTIAL
Writer: Anna Roberts File Name: f-ch5 Installing Hardware Options Hot-Plug.doc
Codename: Expedition Part Number: 270854-002 Last Saved On: 6/17/03 2:09 PM