Installing Hardware Options, Hot-Plug
Installing a StorageWorks Hot-Plug Tape Drive
To install a StorageWorks hot-plug tape drive in the drive cage:
1. StorageWorks hot-plug tape drives require two drive bays for installation, so you
must remove two drive blanks. Remove the drive blank from hot-plug drive bays
zero and one. Refer to “Installing a Hot-Plug SCSI Hard Disk Drive” in this
chapter.
2. Align the StorageWorks hot-plug tape drive with the open drive bays and slide
the tape drive into the drive bays until the release latch seats.
Figure 5-14: Installing a StorageWorks hot-plug tape
drive
3. Be sure that the tape drive LED on the front of the tape drive is illuminated
green, indicating that the system is functioning properly. For detailed information
on LEDs, refer to Appendix D, “LED Indicators and Switches.”
4. If any of the LEDs indicate an error, refer to Appendix E or refer to the HP
Servers Troubleshooting Guide for instructions.
For more information about installing the StorageWorks hot-plug tape drive, refer to
the installation documentation provided with the drive.
HP ProLiant DL740 Server User Guide 5-31
HP CONFIDENTIAL
Writer: Anna Roberts File Name: f-ch5 Installing Hardware Options Hot-Plug.doc
Codename: Expedition Part Number: 270854-002 Last Saved On: 6/17/03 2:09 PM
Vista de pagina 129
1 2 ... 125 126 127 128 129 130 131 132 133 134 135 ... 276 277

Comentarios a estos manuales

Sin comentarios