Operations 30
If the screws lack Nylok coating or are used, add Loctite 242 Threadlocker 3~5 threads from the tip.
6. Install M2.5x6 mm wafer head screws (the same screws removed in step 1) through the heat spreader,
plate tab, and process control board hole alignment to the baseplate, and then torque both screws to
4.0~4.5 in-lbf.
If the screws do not have Nylok coating, or are used, add Loctite 242 Threadlocker 3~5 threads from
the tip.