Hp 9000 V2600 SCA Manual de usuario

Busca en linea o descarga Manual de usuario para Ordenadores Hp 9000 V2600 SCA. HP 9000 V2600 SCA User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Operator’s Guide

Operator’s GuideHP 9000 V2500/V2600 SCA Server First EditionA5845-96001Customer Order Number: A5845-90001July 1999Printed in: USA

Pagina 2 - Revision History

x List of Figures Figure 41 ts_config “Add/Configure Terminal Mux” selection. . . . . . . . . . . . . . . . . . . 84 Figure 42 Terminal mux IP addres

Pagina 3 - Contents

78 Chapter 5 Configuration utilitiests_config Figure 30 ts_config indicating Node 0 as not configuredStep 2. Select “Actions” and then click “Configur

Pagina 4

Chapter 5 79Configuration utilitiests_config Figure 32 ts_config node configuration panelStep 3. Enter a name for the V2500/V2600 System. The SSP uses

Pagina 5

80 Chapter 5 Configuration utilitiests_config Figure 33 ts_config restart workspace manager panel.Step 6. Read the panel and click “OK.” When the conf

Pagina 6

Chapter 5 81Configuration utilitiests_configConfigure the scub_ip addressStep 1. Select the desired node from the list of available nodes.Step 2. In t

Pagina 7

82 Chapter 5 Configuration utilitiests_config Figure 37 ts_config scub_ip address configuration confirmationStep 4. A panel as the shown in Figure 38

Pagina 8

Chapter 5 83Configuration utilitiests_config Figure 39 ts_config “Reset Node” selectionA panel as the one shown in Figure 40 appears. Figure 40 ts_con

Pagina 9

84 Chapter 5 Configuration utilitiests_configDeconfigure a NodeDeconfiguring a node removes the selected node from the SSP configuration. The SSP will

Pagina 10

Chapter 5 85Configuration utilitiests_config Figure 42 Terminal mux IP address panelRemove terminal muxts_config does not remove the terminal mux if a

Pagina 11

86 Chapter 5 Configuration utilitiests_config Figure 43 “Start Console Session” selection Figure 44 Started console sessions

Pagina 12

Chapter 5 87Configuration utilitiests_configV2500/V2600 SCA (multinode) configurationts_config can also configure a V2500/V2600 SCA system. An example

Pagina 13 - Preface xiii

List of Tables xiTablesTable 1 Valid CTI cache sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Table

Pagina 14 - Notational conventions

88 Chapter 5 Configuration utilitiests_config Figure 46 ts_config Configure Multinode complex selectionStep 3. When “Configure Multinode complex” is s

Pagina 15

Chapter 5 89Configuration utilitiests_configStep 4. Enter the required fields into the Configure Multinode Complex dialog window.• V-Class Complex Nam

Pagina 16 - Safety in material handling

90 Chapter 5 Configuration utilitiests_config Figure 48 Configure Multinode Complex dialog window with appropriate valuesStep 10. Click the “Configure

Pagina 17 - BCIQ (Taiwan)

Chapter 5 91Configuration utilitiests_configThis information includes:•Node ID• Complex serial number (if it has been modified)• Requested or auto-gen

Pagina 18 - 3862H354

92 Chapter 5 Configuration utilitiests_config Figure 50 ts_config showing newly configured complexesWhen remotely running ts_config, the Restart Works

Pagina 19 - Fuse cautions

Chapter 5 93Configuration utilitiests_config Figure 51 ts_config Split Multinode complex operation Figure 52 ts_config Split Multinode complex panelSt

Pagina 20 - Associated documents

94 Chapter 5 Configuration utilitiests_config Figure 53 ts_config Split Multinode complex panel filled inThe message shown in Figure 54 appears indica

Pagina 21 - Technical assistance

Chapter 5 95Configuration utilitiests_configts_config filests_config either reads or maintains the following SSP configuration files:/etc/hosts The s

Pagina 22 - Reader feedback

96 Chapter 5 Configuration utilitiests_configNODE Complex Node ID JTAG-hostname OBP-hostname SSP-hostname Console-portThe variables of the entry are d

Pagina 23 - 1Overview

Chapter 5 97Configuration utilitiesSSP-to-system communicationsSSP-to-system communicationsFigure 56 depicts the V-Class server to SSP communications

Pagina 25 - The Service Support Processor

98 Chapter 5 Configuration utilitiesSSP-to-system communicationsLAN communicationsThere are two ethernet ports located on the SCUB as shown in the dia

Pagina 26

Chapter 5 99Configuration utilitiesSSP-to-system communicationsSerial communicationsThe DUART port on the SCUB provides an RS232 serial link to the SS

Pagina 27 - SSP Workstation

100 Chapter 5 Configuration utilitiesccmdccmdccmd (Complex Configuration Management Daemon) is a daemon that maintains a database of information about

Pagina 28 - V-Class Server Architecture

Chapter 5 101Configuration utilitiesccmdIf started with no options, ccmd disassociates itself from the terminal or window where it was started. It ins

Pagina 29 - HyperPlane Crossbar

102 Chapter 5 Configuration utilitiesxconfigxconfigxconfig is the graphical tool that can also modify the parameters initialized by POST to reconfigur

Pagina 30

Chapter 5 103Configuration utilitiesxconfig Figure 57 xconfig window—physical location names

Pagina 31 - Processors

104 Chapter 5 Configuration utilitiesxconfig Figure 58 xconfig window—logical namesAs buttons are clicked, the item selected changes state and color.

Pagina 32

Chapter 5 105Configuration utilitiesxconfigThe main xconfig window has three sections:• Menu bar—Provides additional capability and functions.• Node c

Pagina 33 - CTI Cache Memory

106 Chapter 5 Configuration utilitiesxconfigNode configuration mapThe node configuration map is a representation of the left and right side views of a

Pagina 34 - Input/Output

Chapter 5 107Configuration utilitiesxconfigThe button boxes are positioned to represent the actual boards as viewed from the left and right sides. Eac

Pagina 35 - 0123 0123

Preface xiiiPrefaceThe Operator’s Guide HP 9000 V2500/V2600 Server documents the information necessary to operate and monitor HP V-Class servers. This

Pagina 36

108 Chapter 5 Configuration utilitiesxconfig Figure 61 xconfig window node control panelThe node number is shown in the node box. A new number can be

Pagina 37

Chapter 5 109Configuration utilitiesxconfigWhen a new node is selected and available, its data is automatically read and the node configuration map up

Pagina 38

110 Chapter 5 Configuration utilitiesConfiguration utilitiesConfiguration utilitiesV2500/V2600 diagnostics provides utilities that assist the user wit

Pagina 39

Chapter 5 111Configuration utilitiesConfiguration utilitiesNOTE If there is a node_#.pwr file that is older than the node_#.cfg file, existing node co

Pagina 40

112 Chapter 5 Configuration utilitiesConfiguration utilitiesEffects of hardware and software deconfigurationreport_cfg counts all processors, STACs, S

Pagina 41 - Chapter 1 19

Chapter 5 113Configuration utilitiesConfiguration utilitiesreport_cfg ASIC reportTo obtain a report on the ASICs in a complex, use the -A option. The

Pagina 42 - 20 Chapter 1

114 Chapter 5 Configuration utilitiesConfiguration utilitiesreport_cfg memory reportTo obtain a report on the memory in a complex, use the -m option.

Pagina 43 - 2 Indicators, switches, and

Chapter 5 115Configuration utilitiesConfiguration utilitiesreport_cfg processor reportTo obtain a report on the processor in a complex, use the -p opt

Pagina 44 - Optional DAT drive

116 Chapter 5 Configuration utilitiesConfiguration utilitiesIf the command line [-on | -off | -check] options are used, xsecure does not use the GUI i

Pagina 45

Chapter 6 1176 HP-UX Operating SystemDifferent versions of the HP-UX operating system run on a V-Class server and its Service Support Processor. This

Pagina 46 - Eject button

xiv Preface PrefaceNotational conventionsThis section describes notational conventions used in this book.bold monospace In command examples, bold mon

Pagina 47

118 Chapter 6 HP-UX Operating SystemHP-UX on the V2500/V2600HP-UX on the V2500/V2600In general HP-UX administration tasks are performed on V-Class ser

Pagina 48

Chapter 6 119HP-UX Operating SystemHP-UX on the V2500/V2600On multiple-cabinet V2500/V2600 servers, the first component of the hardware path indicates

Pagina 49 - Attention light bar

120 Chapter 6 HP-UX Operating SystemHP-UX on the V2500/V2600Configuring HP-UX for V-Class ServersHP-UX V11.0 provides several tuned parameter sets tha

Pagina 50 - IIII IIII IIII IIII

Chapter 6 121HP-UX Operating SystemHP-UX on the V2500/V2600• Dedicated commercial data processing use—Servers whose use is restricted for online trans

Pagina 51

122 Chapter 6 HP-UX Operating SystemHP-UX on the V2500/V2600/usr/sam/lib/kc/tunedRefer to the SAM online help for examples and details on using kernel

Pagina 52 - Message display line

Chapter 6 123HP-UX Operating SystemHP-UX on the V2500/V2600extensions also provide system inquiry features for retrieving information about the curren

Pagina 53

124 Chapter 6 HP-UX Operating SystemHP-UX on the V2500/V2600• Fill First—Fill a locality first, then spill over to another locality, as needed. Once a

Pagina 54 - Environmental errors

Chapter 6 125HP-UX Operating SystemStarting HP-UXStarting HP-UXBringing the V-Class server to a usable state involves two systems and their hardware a

Pagina 55

126 Chapter 6 HP-UX Operating SystemStarting HP-UXStart up, or boot, HP-UX after the operating system has been completely shut down or partially shut

Pagina 56 - System Displays

Chapter 6 127HP-UX Operating SystemStarting HP-UXStep 4. Issue the OBP menu’s BOOT command to boot HP-UX on the V-Class server.You can set the server

Pagina 57 - 3 SSP operation

Preface xvPrefaceNOTE A note highlights important supplemental information.CAUTION Cautions highlight procedures or information necessary to avoid inj

Pagina 58 - SSP and the V-Class system

128 Chapter 6 HP-UX Operating SystemStarting HP-UXTable 14 Boot variablesReviewing the state of the file systemDuring the start-up process, the /sbin/

Pagina 59 - SSP log-on

Chapter 6 129HP-UX Operating SystemStarting HP-UXThe start-up process is interrupted:/usr/sbin/fsclean:/dev/dsk/0s0 not ok run fsck FILE SYSTEM(S) NOT

Pagina 60 - SSP operation

130 Chapter 6 HP-UX Operating SystemStopping HP-UXStopping HP-UXThis section provides a brief overview of the process; for complete instructions, see

Pagina 61 - Chapter 3 39

Chapter 6 131HP-UX Operating SystemStopping HP-UXSee the shutdown man page for a complete description of the shutdown process and available options.

Pagina 62 - Console bar

132 Chapter 6 HP-UX Operating SystemStopping HP-UXRebooting the system To shutdown HP-UX and reboot the V-Class server, perform the following steps:St

Pagina 63 - Environment) Workspace menu

Chapter 6 133HP-UX Operating SystemStopping HP-UXShutting down the system To shut down the V-Class server, perform the following steps:Step 1. Login t

Pagina 64 - 42 Chapter 3

134 Chapter 6 HP-UX Operating SystemStopping HP-UXResetting the V2500/V2600 server hardwareThe /spp/bin/do_reset command resets the V-Class hardware.

Pagina 65

Chapter 6 135HP-UX Operating SystemStopping HP-UXPerforms a level 4 reset of all cabinets. This causes a Transfer of Control (TOC) that initiates a cr

Pagina 66

136 Chapter 6 HP-UX Operating SystemStopping HP-UX

Pagina 67 - Using the console

Chapter 7 1377 Recovering from failuresThis chapter provides detailed information on recovering from HP-UX system interruptions.Usually, the first ind

Pagina 68

xvi Preface PrefaceSafety and regulatory informationFor your protection, this product has been tested to various national and international regulation

Pagina 69

138 Chapter 7 Recovering from failuresCollecting informationCollecting information Providing the Response Center with a complete and accurate symptom

Pagina 70

Chapter 7 139Recovering from failuresPerformance problemsPerformance problemsPerformance problems are generally perceived as:• Sluggish response at th

Pagina 71 - Console commands

140 Chapter 7 Recovering from failuresSystem hangsSystem hangsSystem hangs are characterized by users unable to access the system, although the LCD di

Pagina 72 - Watching the console

Chapter 7 141Recovering from failuresSystem panicsSystem panicsA system panic is the result of HP-UX encountering a condition that it is unable to res

Pagina 73 - CTRL-Ecs

142 Chapter 7 Recovering from failuresSystem panicsStep 2. Record the panic message displayed on the system console. Look for text on the console that

Pagina 74 - The set_complex command

Chapter 7 143Recovering from failuresSystem panics2. Take the device offline.3. Power down the device.4. If it is a disk drive, wait for the disk to s

Pagina 75 - Targeting commands to nodes

144 Chapter 7 Recovering from failuresSystem panicsStep 4. If the system does not reboot by itself, reboot the computer by issuing the reset command i

Pagina 76 - SSP file system

Chapter 7 145Recovering from failuresSystem panicsLogical Volume Manager (LVM) related problemIf the size of a logical volume that contains a file sys

Pagina 77 - /spp/data/complex_name

146 Chapter 7 Recovering from failuresRebooting the systemRebooting the systemOnce a problem has been corrected, reset and reboot the system. Step 1.

Pagina 78 - /spp/man

Chapter 7 147Recovering from failuresAbnormal system shutdownsAbnormal system shutdownsAbnormal systems shutdowns (often referred to as system crashes

Pagina 79 - Device files

Preface xviiPrefaceJapanese radio frequency interference VCCI Figure 1 Japanese radio frequency noticeThis equipment is a Class A category (Informatio

Pagina 80 - System log pathnames

148 Chapter 7 Recovering from failuresAbnormal system shutdownsThe on-disk and file system formats of a crash dump have changed with HP-UX 11.0. libcr

Pagina 81 - 4 Firmware (OBP and PDC)

Chapter 7 149Recovering from failuresAbnormal system shutdownsIMPORTANT Crashdump must be configured to dump on cabinet zero disks only.It is importan

Pagina 82 - Boot sequence

150 Chapter 7 Recovering from failuresAbnormal system shutdownsTo calculate an appropriate size for a V2500/V2600 SCA crash dump volume, estimate that

Pagina 83

Chapter 7 151Recovering from failuresAbnormal system shutdownsThe fewer pages dumped to disk (and on reboot, copied to the HP-UX file system area), th

Pagina 84 - Boot process output

152 Chapter 7 Recovering from failuresAbnormal system shutdowns/etc/rc.config.d/savecrash) reduces system recovery time. After the system recovery, ru

Pagina 85 - Firmware (OBP and PDC)

Chapter 7 153Recovering from failuresAbnormal system shutdownsDump definitions built into the kernel vs. defined at runtimeThere are three places to d

Pagina 86 - HP mode boot menu

154 Chapter 7 Recovering from failuresAbnormal system shutdownspaging from being enabled to the device by creating the file /etc/savecore.LCK. swapon

Pagina 87

Chapter 7 155Recovering from failuresAbnormal system shutdownsNOTE With HP-UX 11.0, it is possible to analyze a crash dump directly from dump devices

Pagina 88

156 Chapter 7 Recovering from failuresAbnormal system shutdownsCLASS PAGES INCLUDED IN DUMP DESCRIPTION-------- ---------- --------------

Pagina 89 - Enabling Autoboot

Chapter 7 157Recovering from failuresAbnormal system shutdownsStep 3. Use the SAM action menu to add, remove, or modify devices or logical volumes.NOT

Pagina 90 - Examples

xviii Preface Preface Figure 2 BCIQ (Taiwan)Acoustics (Germany)Laermangabe (Schalldruckpregel LpA) gemessen am fiktiver Arbeitsplatz bei normalem Betr

Pagina 91

158 Chapter 7 Recovering from failuresAbnormal system shutdowns• The logical volume cannot be used for file system storage, because the whole logical

Pagina 92 - HElp command

Chapter 7 159Recovering from failuresAbnormal system shutdownsThe /etc/fstab fileDefine entries in the fstab file to activate dump devices during the

Pagina 93 - 5 Configuration utilities

160 Chapter 7 Recovering from failuresAbnormal system shutdownsTo have crashconf add the devices represented by the block device files /dev/dsk/c0t1d0

Pagina 94 - Starting ts_config

Chapter 7 161Recovering from failuresAbnormal system shutdownsOperator override optionsWhen the system crashes, the system console displays a panic me

Pagina 95

162 Chapter 7 Recovering from failuresAbnormal system shutdownsFollowing the dump, the system attempts to reboot.The rebootWhen dumping of physical me

Pagina 96

Chapter 7 163Recovering from failuresAbnormal system shutdownsUsing crashutil to complete the saving of a dumpIf devices are being used for both pagin

Pagina 97 - Configuration procedures

164 Chapter 7 Recovering from failuresAbnormal system shutdownsdestination Designates the pathname where the converted file will be written. If no de

Pagina 98

Appendix A 165ALED codesThis appendix describes core utilities board (CUB) LED errors The Attention LED on the core utilities board (CUB) turns on, an

Pagina 99 - Configure a Node

166 Appendix A LED codesPower on detected errorsPower on detected errorsThis section describes core utilities board (CUB) LED errors from highest to l

Pagina 100

Appendix A 167LED codesPower on detected errors03 FPGA not OK 1. Core Utilities Board (CUB) monitoring utilities chip (MUC) problem.2. MUC cannot get

Pagina 101

Preface xixPrefaceInstallation conditions (U.S.)See installation instructions before connecting to the supply.Voir la notice d’installation avant de r

Pagina 102

168 Appendix A LED codesPower on detected errors08-11 48V error NPSUL failurePWRUP=0-91. Error occurs when 48 volt distribution falls below 42 volts d

Pagina 103 - Configure the scub_ip address

Appendix A 169LED codesPower on detected errors1C-25 48V error NPSLL failurePWRUP=0-91. Error occurs when 48 volt distribution falls below 42 volts du

Pagina 104 - Reset the Node

170 Appendix A LED codesPower on detected errors30-39 48V error (maintenance)no supply failure reportedPWRUP=0-91. Error occurs when 48 volt distribut

Pagina 105

Appendix A 171LED codesCUB detected memory power failCUB detected memory power failThis describes covers memory errors detected by the monitoring util

Pagina 106 - Deconfigure a Node

172 Appendix A LED codesCUB detected processor errorCUB detected processor errorThis section describes processor errors detected by the monitoring uti

Pagina 107 - Console sessions

Appendix A 173LED codesCUB detected I/O errorCUB detected I/O errorThis section describes I/O errors detected by the monitoring utilities chip (MUC) o

Pagina 108 - Configuration utilities

174 Appendix A LED codesCUB detected fan errorCUB detected fan errorThis section describes fan errors detected by the monitoring utilities chip (MUC)

Pagina 109

Appendix A 175LED codesCUB detected ambient air errorsCUB detected ambient air errorsThis section describes air errors detected by the monitoring util

Pagina 110

176 Appendix A LED codesCUB detected hard errorCUB detected hard errorThis section describes hard errors detected by the monitoring utilities chip (MU

Pagina 111

Appendix A 177LED codesCUB detected intake ambient air errorCUB detected intake ambient air errorThis section describes air intake errors detected by

Pagina 112

Revision HistoryEdition: FirstDocument Number: A5845-96001Notice Copyright Hewlett-Packard Company 1999. All Rights Reserved. Reproduction, adaptatio

Pagina 113

xx Preface PrefaceAssociated documentsAssociated documents include:• HP Diagnostic Guide: V2500/V2600 Servers, (A5824-96002)• HP-UX SCA Programming an

Pagina 114

178 Appendix A LED codesCUB detected dc errorCUB detected dc errorThis section describes dc errors detected by the monitoring utilities chip (MUC) on

Pagina 115

Index 179IndexSymbols/spp directory, 4/spp/bin, 55/spp/data, 55/spp/est, 56/spp/etc, 54/spp/firmware, 56/spp/man, 56/spp/scripts, 55^E key sequence, 4

Pagina 116

180 Index detected memory power fail, 171detected processor error, 172core utility board (CUB), 36CPU. see processor, 9crash dump, 147SCA, 149crashcon

Pagina 117

Index 181HyperPlane Crossbar, 6II/Ocontrollers, 13listing, 118multiple-cabinet numbering, 14numbering, 119physical access, 13supported cards, 12indica

Pagina 118 - /spp/scripts/inst/ts.install

182 Index LVM (Logical Volume Manager), problems, 145Mmaterial handlingsafety, xvimediaDAT, 25tape, 25memory80-bit DIMMs, 1088-bit DIMMs, 10board, 11c

Pagina 119

Index 183power, 23powering down the system, 130Power-On Self Test (POST), 28private ethernet, 36private LAN, 57private LAN see diagnostic LANprocess

Pagina 120 - LAN communications

184 Index Stop-on-hard button, 109supported I/O cards, 12switches, 21Symbios, 98Symmetric Multi-Processing (SMP), 10systemdisplays, 27hangs, 140logs,

Pagina 121 - Serial communications

Preface xxiPrefaceTechnical assistanceIf you have questions that are not answered in this book, contact the Hewlett-Packard Response Center at the fol

Pagina 122

xxii Preface PrefaceReader feedbackThis document was produced by the System Supportability Lab Field Engineering Support organization (SSL/FES). If yo

Pagina 123

Chapter 1 11OverviewThis chapter introduces Hewlett-Packard V-Class system components and includes a brief overview of V2500/V2600 server hardware res

Pagina 124

2 Chapter 1 OverviewV-Class System ComponentsV-Class System ComponentsEach V-Class system includes two main components: a V-Class server and a Service

Pagina 125 - Chapter 5 103

Chapter 1 3OverviewV-Class System ComponentsFigure 4 shows a four-cabinet V2500/V2600 server and the Service Support Processor that is used for consol

Pagina 126

4 Chapter 1 OverviewV-Class System Componentsmonitoring the server hardware, as well as diagnostics operations. You also must use the Service Support

Pagina 127 - Menu bar

Chapter 1 5OverviewV-Class System Components Figure 5 Console and Diagnostic Connections for a Four-Cabinet V2500/V2600 ServerThe console port on cabi

Pagina 128 - Node configuration map

6 Chapter 1 OverviewV-Class Server ArchitectureV-Class Server ArchitectureThe V2500/V2600 server has a powerful set of interconnecting hardware compon

Pagina 129 - Node control panel

Chapter 1 7OverviewV-Class Server Architecture Figure 6 Functional Diagram of a Single-Cabinet V2500/V2600 ServerI/OI/OI/OI/OMemoryCTIPCIControllerMem

Pagina 130

Table of Contents iiiContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 131

8 Chapter 1 OverviewV-Class Server Architecture Figure 7 V2500/V2600 HyperPlane Crossbar ConnectionsEach ERAC has 16 ports, 4 send and 4 receive on ea

Pagina 132

Chapter 1 9OverviewV-Class Server ArchitectureCore Utilities BoardThe utilities board provides boot, diagnostics, and console connections from the V-C

Pagina 133

10 Chapter 1 OverviewV-Class Server ArchitectureThree DIMM sizes are supported for use in V2500/V2600 servers: 32 MByte, 128 MByte, and 256 MByte. Onl

Pagina 134

Chapter 1 11OverviewV-Class Server ArchitectureMemory InterleavingThrough the memory access controllers, each memory board provides separate read and

Pagina 135

12 Chapter 1 OverviewV-Class Server ArchitectureWith small CTI cache sizes, additional aliasing between memory locations may occur, reducing the cache

Pagina 136 - 114 Chapter 5

Chapter 1 13OverviewV-Class Server ArchitectureEach V2500/V2600 I/O port is capable of direct memory access (DMA), which eliminates processor involvem

Pagina 137

14 Chapter 1 OverviewV-Class Server ArchitectureFor multiple-cabinet servers, the PCI bus numbering is as shown in Figure 10. The PCI bus number also

Pagina 138

Chapter 1 15OverviewV-Class Server ArchitectureFor an example of listing I/O devices on various cabinets and details of listing other V-Class server h

Pagina 139 - 6 HP-UX Operating System

16 Chapter 1 OverviewV-Class Server ArchitectureEach CTI controller connects to a corresponding CTI controller on a remote cabinet by cables that prov

Pagina 140 - HP-UX on the V2500/V2600

Chapter 1 17OverviewV-Class Server ArchitectureFor X-dimension connections, CTI cables connect to the opposite controller on the remote cabinet. This

Pagina 141

iv Table of ContentsDVD-ROM drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Disk loading slot . . . . .

Pagina 142 - HP-UX parameter sets

18 Chapter 1 OverviewV2500/V2600 Cabinet ConfigurationsV2500/V2600 Cabinet ConfigurationsThis section shows two sample V2500/V2600 server configuratio

Pagina 143

Chapter 1 19OverviewV2500/V2600 Cabinet Configurations Figure 12 Sample V2500/V2600 Cabinet ConfigurationsA single-cabinet V2500/V2600 server with 16

Pagina 144 - HP-UX 11.10 SCA Enhancements

20 Chapter 1 OverviewV2500/V2600 Cabinet Configurations

Pagina 145 - HP-UX SCA Features

Chapter 2 212 Indicators, switches, and displaysThis section describes indicators, switches, and displays of the HP 9000 V2500 server.

Pagina 146

22 Chapter 2 Indicators, switches, and displaysOperator panelOperator panelThe operator panel is located on the top left side of the server and contai

Pagina 147 - Starting HP-UX

Chapter 2 23Indicators, switches, and displaysOperator panelKey switch panelThe key switch panel is located on the left of the operator panel, as show

Pagina 148 - Power-On Sequence

24 Chapter 2 Indicators, switches, and displaysOperator panelTOCThe TOC (Transfer Of Control) button is a recessed switch that resets the system.DVD-R

Pagina 149 - Boot variables

Chapter 2 25Indicators, switches, and displaysOperator panelBusy indicatorThe busy indicator LED flashes to indicate that a read operation is occurrin

Pagina 150

26 Chapter 2 Indicators, switches, and displaysOperator panelTable 2 Indicator LED operation Eject buttonPush the eject button to remove cartridges fr

Pagina 151 - 3. Other errors detected

Chapter 2 27Indicators, switches, and displaysSystem DisplaysSystem DisplaysThe V-Class servers provide two means of displaying status and error repor

Pagina 152 - Stopping HP-UX

Table of Contents v/spp/bin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55/spp/scripts . . . .

Pagina 153 - HP-UX Operating System

28 Chapter 2 Indicators, switches, and displaysSystem DisplaysLCD (Liquid Crystal Display)The LCD display is located on the right of the operator pane

Pagina 154 - Rebooting the system

Chapter 2 29Indicators, switches, and displaysSystem DisplaysTable 3 Processor initialization stepsTable 4 Processor run-time status codesStep Descrip

Pagina 155 - Shutting down the system

30 Chapter 2 Indicators, switches, and displaysSystem DisplaysMessage display lineThe message display line shows the POST initialization progress. Thi

Pagina 156

Chapter 2 31Indicators, switches, and displaysSystem DisplaysAttention light barThe Attention light bar is located at the top left corner on the front

Pagina 157

32 Chapter 2 Indicators, switches, and displaysSystem DisplaysEnvironmental errorsEnvironmental errors are detected by two basic systems in the V2500/

Pagina 158 - 136 Chapter 6

Chapter 2 33Indicators, switches, and displaysSystem DisplaysIdentifying a node with the blink commandThe blink command is used to physically identify

Pagina 159 - 7 Recovering from failures

34 Chapter 2 Indicators, switches, and displaysSystem Displays

Pagina 160 - Collecting information

Chapter 3 353 SSP operationThis chapter describes the operation the SSP in conjunction with a V-Class server and includes:•SSP log-on• Using the CDE (

Pagina 161 - Performance problems

36 Chapter 3 SSP operationSSP and the V-Class systemSSP and the V-Class systemThe Service Support Processor (SSP) is either a Hewlett-Packard B180L or

Pagina 162 - System hangs

Chapter 3 37SSP operationSSP log-onSSP log-onTwo UNIX user accounts are created on the SSP during the HP-UX 10.20 operating system installation proces

Pagina 163 - System panics

vi Table of ContentsNode configuration map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Node control panel . . . . . . .

Pagina 164 - Peripheral problem

38 Chapter 3 SSP operationSSP log-on Figure 19 SSP user windows for V2500/V2600 servers with one node

Pagina 165

Chapter 3 39SSP operationSSP log-on Figure 20 SSP user windows for V2500/V2600 servers with more than two nodes

Pagina 166 - LAN communication problem

40 Chapter 3 SSP operationSSP log-onMessage windowThe message window displays status from the ccmd daemon running on the SSP approximately 60 seconds

Pagina 167

Chapter 3 41SSP operationUsing the CDE (Common Desktop Environment) Workspace menuUsing the CDE (Common Desktop Environment) Workspace menuThe SSP use

Pagina 168

42 Chapter 3 SSP operationUsing the CDE (Common Desktop Environment) Workspace menu Figure 21 SSP Workspace submenus for V2500/V2600 Figure 22 SSP Wor

Pagina 169 - Abnormal system shutdowns

Chapter 3 43SSP operationUsing the CDE (Common Desktop Environment) Workspace menuV2500/V2600 Workspace menu options include:• V-Class Complex: name—O

Pagina 170

44 Chapter 3 SSP operationUsing the CDE (Common Desktop Environment) Workspace menu• Restart Workspace Manager—Stops and restarts the Workspace Manage

Pagina 171

Chapter 3 45SSP operationUsing the consoleUsing the consoleThe console serves as the communication device for the V-Class server. Virtual consoles are

Pagina 172 - System recovery time

46 Chapter 3 SSP operationUsing the consoleStarting the console from the Workspace menuTo start the console using the Workspace menu, complete the fol

Pagina 173

Chapter 3 47SSP operationUsing the consoleFor example:COMPLEX_NAME = [Select from colossus, guardian] colossusStep 3. Start the console. Enter:sppcons

Pagina 174 - Crash information integrity

Table of Contents viiLogical Volume Manager (LVM) related problem. . . . . . . . . . . . . . . .145Recovery from other situations . . . . . . . . . .

Pagina 175

48 Chapter 3 SSP operationUsing the consoleStep 5. Enter the root password.Refer to “Starting ts_config” on page 92 for information on starting ts_con

Pagina 176 - Disk space needs

Chapter 3 49SSP operationUsing the consoleStarting the console by logging back onThis method of starting the console works from the SSP or after loggi

Pagina 177 - Defining dump devices

50 Chapter 3 SSP operationUsing the consoleExample: Performing a ^E commandTo execute the ^Ecf command complete the following steps:1. Press the Cntrl

Pagina 178

Chapter 3 51SSP operationUsing the consoleCTRL-Ec.The period is part of the command.Assuming control of the consoleSystem maintenance or diagnostics c

Pagina 179

52 Chapter 3 SSP operationUsing the consoleChanging a console connectionOnce the console is started as a watch or a control connection, the connection

Pagina 180

Chapter 3 53SSP operationUsing the consoleprompting the user if only one complex is configured). This utility accesses the desired node based on node

Pagina 181 - /sbin/crashconf -ar

54 Chapter 3 SSP operationSSP file systemSSP file systemThe /spp and /users/sppuser directories contain most of the SSP specific files. Other files in

Pagina 182 - Dump order

Chapter 3 55SSP operationSSP file systemconserver The console-server that directs RS-232 console traffic from the Utility Board to the various sppcon

Pagina 183 - The dump

56 Chapter 3 SSP operationSSP file systemconsolelogX A file containing all the console activity on the system, where X is the node ID.est.log The sc

Pagina 184 - The reboot

Chapter 3 57SSP operationSSP file systemDevice filesTable 8 shows the differences in the device files between the HP B180L and HP 712 SSPs. Table 8 De

Pagina 186 - Analyzing crash dumps

58 Chapter 3 SSP operationSystem log pathnamesSystem log pathnamesTo separate the configuration and log files for each complex, several files have bee

Pagina 187 - ALED codes

Chapter 4 594 Firmware (OBP and PDC) This chapter discusses the boot sequence and the commands available from the boot menu.

Pagina 188 - Power on detected errors

60 Chapter 4 Firmware (OBP and PDC)Boot sequenceBoot sequenceOpenBoot PROM (OBP) and SPP Processor Dependent Code (SPP_PDC) make up the firmware on HP

Pagina 189

Chapter 4 61Firmware (OBP and PDC)Boot sequence Figure 24 Boot processNONOYESYESBoot menu Prompt displays:To discontinue, press any key within 10 seco

Pagina 190

62 Chapter 4 Firmware (OBP and PDC)Boot process outputBoot process outputThe following output illustrates what typically displays on the console as th

Pagina 191

Chapter 4 63Firmware (OBP and PDC)Boot process output-------------------------------------------------------------------------------

Pagina 192

64 Chapter 4 Firmware (OBP and PDC)HP mode boot menuHP mode boot menuIn some instances, the boot menu displays; otherwise the operating system boots a

Pagina 193

Chapter 4 65Firmware (OBP and PDC)HP mode boot menu Table 10 lists the commands available from the Command: prompt.Table 10 Boot menu commandsCommand

Pagina 194 - CUB detected processor error

66 Chapter 4 Firmware (OBP and PDC)HP mode boot menuPAth [PRI|ALT|CON] [path] Displays or sets primary, alternate, console, and keyboard hardware path

Pagina 195 - CUB detected I/O error

Chapter 4 67Firmware (OBP and PDC)Enabling AutobootEnabling AutobootAUto displays or sets the Autoboot or Search flag, which sets the way a system wil

Pagina 196 - CUB detected fan error

List of Figures ixFigures Figure 1 Japanese radio frequency notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii Figure 2

Pagina 197

68 Chapter 4 Firmware (OBP and PDC)Enabling AutobootExamplesau This command displays the status of the Autoboot and Autosearch flags.Autoboot:ONAutos

Pagina 198 - CUB detected hard error

Chapter 4 69Firmware (OBP and PDC)HElp commandHElp commandThe help command displays help information for the specified command or redisplays the boot

Pagina 199

70 Chapter 4 Firmware (OBP and PDC)HElp command

Pagina 200 - CUB detected dc error

Chapter 5 715 Configuration utilitiesThis chapter describes server configuration management and includes:• ts_config• ccmd• xconfig• Configuration uti

Pagina 201 - Index 179

72 Chapter 5 Configuration utilitiests_configts_configts_config [-display display name]Any V2500/V2600 nodes added to the SSP must be configured by ts

Pagina 202 - 180 Index

Chapter 5 73Configuration utilitiests_configFor example:$ DISPLAY=myws:0; export DISPLAY (sh/ksh/sppdsh)% setenv DISPLAY myws:0 (csh/tcsh)Al

Pagina 203 - Index 181

74 Chapter 5 Configuration utilitiests_configts_config automatically updates the display when it detects either a change in the configuration status o

Pagina 204 - 182 Index

Chapter 5 75Configuration utilitiests_configConfiguration proceduresThe following procedures provide additional details about each configuration actio

Pagina 205 - Index 183

76 Chapter 5 Configuration utilitiests_config Figure 26 ts_config showing node 0 highlightedNotice that after the node has been highlighted that ts_co

Pagina 206 - 184 Index

Chapter 5 77Configuration utilitiests_config Figure 28 Upgrade JTAG firmware confirmation panelStep 4. After the firmware is loaded a panel appears as