35
Valid Keystrokes Action
n/a The ROM test ignores the keyboard.
Failure Message Error Code Meaning
User Aborted 1 User aborted test.
PCMCIA - (PCMCIA.COM)
The PCMCIA test sets up the TI CardBus controller chip, tests IRQ 3, and restores the chip.
DOS Parameter Explanation
0 Test lower slot
1 (or any non-0 value) Test upper slot
Valid Keystrokes Action
n/a The PCMCIA test ignores the keyboard.
Failure Message Error Code Meaning
User Aborted 1 User aborted test.
Failed 2 IRQ fail
Internal IR - (FIRTEST.EXE)
This test performs a minimal test of the IR chip but does not require a second OmniBook. The
Full 2 Unit IR test is a more thorough test and does require a second OmniBook (see next
section).
DOS Parameter Explanation
Internal Performs the internal (standalone) test.
Valid Keystrokes Action
n/a The Internal IR test ignores the keyboard.
Failure Message Error Code Meaning
Must clean boot 1 CPU protected mode bit set,
must clean boot.
Must undock 3 This test cannot run while
docked. Can also get this
error if the internal transmit
failed.
Failed 5 Receive fail or any other fail.