25. Remove the purger quick connector.
Problems with the ink sensor value
1. There are three different cases that can cause a problem.
●
The pressure sensor value is below a limit, which may vary depending on the volume of the
supply. Probably there is an air bubble inside the cartridge connector tube column. Prepare
the syringe again. Press OK and continue with step 2.
●
The ink volume of the cartridge is too low to register on the pressure sensor. To ensure there
are no air bubbles in the tube, you are recommended to purge again. Press BACK and
continue with step 2. If you think there are no air bubbles, press OK and continue the process
of purging the ISM tubes from where you were.