HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide January 2004 (Fourth Edition) Part Number 316078-004
Illustrated Parts Catalog Server Blade Spare Parts List Table 1-1: Server Blade Spare Parts List Item Description Spare Part Number Mechanical Com
Illustrated Parts Catalog 1-4 HP ProLiant BL20p Server Blade Generation 2 Maintenance and Service Guide Table 1-1: Server Blade Spare Parts List con
2 Removal and Replacement Procedures This chapter provides subassembly/module-level removal and replacement procedures for system components. After co
Removal and Replacement Procedures WARNING: To reduce the risk of injury from high-current electrical energy, do not remove the server blade access
Removal and Replacement Procedures WARNING: To reduce the risk of personal injury or damage to the equipment, at least two people are needed to saf
Removal and Replacement Procedures Server Blade Components Use the procedures in this section to perform service events on ProLiant BL20p G2 server bl
Removal and Replacement Procedures Figure 2-1: Pressing the Power On/Standby button CAUTION: After you press the release button, the server blade
Removal and Replacement Procedures 3. Remove the server blade from the server blade enclosure: a. Press the release button (1). b. Open the lever (
Removal and Replacement Procedures Access Panel To remove the access panel: 1. Power down the server blade and remove it from the server blade enclos
Removal and Replacement Procedures Hard Drive Blanks To remove a hard drive blank: 1. Press the release buttons simultaneously (1). 2. Pull the blan
© Copyright 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties f
Removal and Replacement Procedures Hot-Plug SCSI Hard Drives To assess hard drive status, observe the hot-plug SCSI hard drive status LEDs. For a deta
Removal and Replacement Procedures DIMMs To remove a DIMM: 1. Power down the server blade and remove it from the server blade enclosure. Refer to the
Removal and Replacement Procedures Processors, Heatsinks, and Processor Power Modules To remove a processor: 1. Power down the server blade and remov
Removal and Replacement Procedures 5. Raise the locking lever to release the processor (1), and remove the processor (2). Figure 2-8: Removing the
Removal and Replacement Procedures CAUTION: After the cover is removed, do not touch the thermal interface media. Touching the thermal interface me
Removal and Replacement Procedures Battery-Backed Write Cache Enabler To remove the Battery-Backed Write Cache Enabler: 1. Power down the server blad
Removal and Replacement Procedures 4. Remove the Battery-Backed Write Cache Enabler from the Smart Array 5i Plus Controller module. Figure 2-12: Rem
Removal and Replacement Procedures 6. Disconnect the cable from the bottom of the Smart Array 5i Plus Controller module. Figure 2-14: Disconnecting
Removal and Replacement Procedures Fan Assembly To remove the fan assembly: 1. Power down the server blade and remove it from the server blade enclos
Removal and Replacement Procedures 4. Press the fan retention tab (1), and lift up the assembly (2). Figure 2-17: Removing a fan assembly Reverse s
Contents About This Guide Audience Assumptions...
Removal and Replacement Procedures Smart Array 5i Plus Controller Module To remove the Smart Array 5i Plus Controller module: 1. Power down the serve
Removal and Replacement Procedures NIC Modules To remove the standard NIC module: 1. Power down the server blade and remove it from the server blade
Removal and Replacement Procedures Dual Port Fibre Channel Mezzanine Card An optional dual port Fibre Channel (FC) mezzanine card enables Fibre Chann
Removal and Replacement Procedures SCSI Backplane To remove the SCSI backplane: 1. Power down the server blade and remove it from the server blade en
Removal and Replacement Procedures 8. Remove the plastic fan baffle (1), and disconnect the SCSI backplane cable from the system board (2). CAUTIO
Removal and Replacement Procedures Power Button/LED Board To remove the power button/LED board: 1. Power down the server blade and remove it from th
Removal and Replacement Procedures 7. Tilt the front edge of the power button/LED board down until the keyholes on the rear of the board clear the al
Removal and Replacement Procedures CAUTION: Loss of BIOS settings occurs if the lithium battery is removed. BIOS settings must be reconfigured when
Removal and Replacement Procedures System Board To remove the system board: 1. Power down the server blade and remove it from the server blade enclos
Removal and Replacement Procedures 11. Loosen the system board thumbscrews. Note that the thumbscrew between the VHDM connector and the DC filter modu
Contents Chapter 3 Diagnostic Tools ProLiant BL p-Class Diagnostic Tools ...
Removal and Replacement Procedures 14. Lift the edge of the system board nearest the system switches. The edge of the system board nearest the Smart A
Removal and Replacement Procedures 2-30 HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide Server Blade Blanks To remove a
3 Diagnostic Tools ProLiant BL p-Class Diagnostic Tools Use the following tools to diagnose problems, test hardware, and monitor and manage system ope
Diagnostic Tools Table 3-1: Diagnostic Tools continued Tool Description How to run the tool HP Diagnostics HP Diagnostics tests and verifies opera
Diagnostic Tools HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide 3-3 Table 3-1: Diagnostic Tools continued Tool Descrip
4 Connectors, LEDs, and Switches Connectors ProLiant BL20p Generation 2 Server Blade Front Panel Connectors The server blade has one front panel conne
Connectors, LEDs, and Switches Rear Panel Connectors Use Figure 4-2 and Table 4-1 to identify ProLiant BL20p G2 server blade rear panel connectors. F
Connectors, LEDs, and Switches System Board Components and Connectors Use Figure 4-3 and Table 4-2 to identify ProLiant BL20p G2 system board componen
Connectors, LEDs, and Switches Table 4-2: System Board Components and Connectors continued Item Description 12 Fan connectors 13 Power button/LED bo
Connectors, LEDs, and Switches Refer to Figure 4-4 to identify the I/O icon. Refer to Figure 4-5 and Table 4-3 to identify diagnostic cable connectors
About This Guide This maintenance and service guide can be used for reference when servicing HP ProLiant BL20p Generation 2 server blades. WARNING:
Connectors, LEDs, and Switches Figure 4-5: Diagnostic and Local I/O cable connectors Table 4-3: Diagnostic and Local I/O Cable Connectors Item Des
Connectors, LEDs, and Switches LEDs Use the following section to identify LEDs on the following ProLiant BL p-Class system components: • • ProLiant B
Connectors, LEDs, and Switches Table 4-4: ProLiant BL20p G2 Server Blade Front Panel LEDs Item LED Description Status 1 Unit identification Blue
Connectors, LEDs, and Switches Table 4-5: Hot-Plug SCSI Hard Drive LEDs 1 Activity 2 Online 3 Fault Means On Off Off Do not remove the drive. Rem
Connectors, LEDs, and Switches Switches Use the following sections to identify the locations and functions of push-button and system switches. Buttons
Connectors, LEDs, and Switches System Switches System switches enable you to change certain settings or to perform advanced diagnostic procedures. The
Connectors, LEDs, and Switches NMI Switch Crash dump analysis is an essential part of eliminating reliability problems such as hangs or crashes in op
Connectors, LEDs, and Switches 7. Power up the server blade: — Press the Power On/Standby button on the front of the server blade. — Use the virtua
Connectors, LEDs, and Switches 4-14 HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide Accessing the Redundant ROM If the sy
Index component-level repairs v configurations, clearing the system configuration 4-12 A access panel connectors removing 2-7 NIC module 4-3
About This Guide CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in.) of clearance at the front and back of the se
Index L guides HP ProLiant BL p-Class System Setup and Installation Guide 3-2 LEDs hot-plug SCSI hard drive 4-8 HP ProLiant Servers Troubleshootin
Index R S rack SCSI backplane cautions 2-2 part number 1-3 warnings 2-2 removing 2-22 weight 2-3 replacing 2-23 RBSU See ROM-Based
Index U RBSU 3-3 ROMPaq 3-2 unit identification (UID), LEDs 4-8 Survey Utility 3-2 utilities Diagnostics 3-2 V HP ProLiant Essentials Rapid
About This Guide Where to Go for Additional Help In addition to this guide, the following information sources are available: • HP ProLiant BL System
1 Illustrated Parts Catalog This chapter provides illustrated parts and spare parts lists for the HP ProLiant BL20p Generation 2 server blade componen
Illustrated Parts Catalog ProLiant BL20p Generation 2 Server Blade Components System Exploded View Figure 1-1: System exploded view 1-2 HP ProLiant