ROM Based Setup (F10) and Start-
up Diagnostics
—
Yes
System Environmental Specs
System Environmental SpecsSystem Environmental Specs
System Environmental Specs
Acoustics: Advanced Power
Management - On
Seated operator position
Idle (Hard drive spinning but not
seeking) = 28 dBA
Shock
Operating
(*Using 11-ms half-sine shock
pulse)
-----
5 G's* (with no damage being
incurred)
Non-Operating
(*Using 11-ms half-sine shock
pulse)
-----
10 G's*, positive and negative
directions front to back axis: 20
G's* in all other axes
Vibration
Operating
-----
Random vibration at 0.000215
G²/Hz, 10Hz to 300Hz, (0.25G's
nominal)
Non-Operating
-----
Random vibration at 0.0005
G²/Hz, 10Hz to 500Hz, (0.5G's
nominal)
Relative Humidity
Operating
(maximum wet bulb temp., non-
condensing)
-----
10% to 90% relative humidity (Rh),
28°C
Non-operating
(maximum wet bulb temp., non-
condensing)
-----
5% to 95% relative humidity (Rh),
38.7°C
Altitude Max (un-pressurized)
Operating
(Maximum allowable altitude
change rate is 1500 ft/min.)
-----
0 to 10,000 feet (3,048 meters) -
This value may be limited by the
type and number of options
installed.
Non-operating
(Maximum allowable altitude
change rate is 1500 ft/min)
-----
0 to 30,000 ft ( 9,144 m)