HP StorageWorks1510i Modular Smart Array maintenance andservice guidePart number: 383072–002Second edition: May 2008
•http://www.hp.com/go/storage•http://www.hp.com/go/servers•http://www.hp.com/service_locator•http://www.hp.com/support•http://www.hp.com/support/manua
1 Illustrated parts listThis section provides an illustrated parts breakdown and spare parts list for the HP StorageWorks 1510iModular Smart Array (MS
7M SA 1510 i c o n t r o l l e rwith 256 MB cachemodule and batteries417787–001 AD539–04001Optional8MSA controllerblanking panel229208–001n/a Mandator
2SpecificationsThis section provides operating and performance specifications for the MSA1510i.Included in this section:• Chassis specifications• 2-Port
Chassis specificationsParameterValueHeight8.79 cm (3.46 in)Width48.41cm(19.06in)Depth61.77cm(24.32in)Weight 24.95 kg (55 lb)Input voltage requirementsR
Fan module specificationsParameterValueHeight6.0 cm (2.36 in)Width6.0 cm (2.36 in)Depth26.8 cm (10.6 in)Weight 0.50 kg (1.10 lbs)SCSI I/O module specifi
16Specifications
3 System components and LEDsThis chapter includes fi gures and tables that identify system components and describe chassis andmodule LEDs patterns.•Fro
Rear view1. 2–Port Ethernet iSCSI module (for the controller in slot 1)2. Chassis slot diagram3. Blank foradditional 2-Port Ethernet iSCSI module (for
Chassis and component LEDsThe MSA chassisand its modular components are equipped with LEDs. When the fault LED on any MSAcomponent is amber, promptly
Legal and notice information© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with
NOTE:System power does not shut off completely with the power button. Standby removes power from most ofthe electronics and the hard drives, but porti
Item NameCondition ColorMeaning1SCSI bus 3 activityOn GreenThereisactivityonthisSCSIbus.2SCSI bus 2 activityOn GreenThereisactivityonthisSCSIbus.3SCSI
Item 1Activity LEDItem 2Online LEDItem 3Fault LEDMeaningOnOff OffThe hard drive is being accessed in one of the following ways:• The hard drive is not
SATA hard driveLEDsEach SATA hard drive has two LEDs. The following figure and table describe their locations and meanings.Item 1Online/Activity LED(gr
Slot diagram LEDsLocated on the rear of the MSA, the slot diagram provides information about MSA modules.1. 2 – Po r t Ethernet iSCSI module (for the
2-Port Ethernet iSCSI module LEDsThe 2-Port Ethernet iSCSI module has one LED to show the status of the module, and each port has twoLEDs to show stat
Fan module LEDsEach fan modulehas one bi-color LED.This LED can be illuminated with either a green or amber color. The following figure and table descr
SCSI I/O module LEDsThe SCSI I/O modulehastwoLEDs. Thefollowingfigure and table describes their locations andmeanings.Item NameCondition ColorDescripti
Power supply module LEDsThe power supply uses a single bi-color LED to indicate status. This LED can be illuminated with either agreen or amber color.
4 Available diagnostic toolsThe following is a partial list of tools that are supported for use with the MSA:•StorageManagementUtility(SMU)overview• M
ContentsAboutthisguide ... 7Intendedaudience... 7Prerequisites ...
third-party devices. HP-SIM reports hardware fault conditions (both failure and pre-failure) and collectsdata for reporting and graphing. HP-SIM also
5 Customer replaceablecomponentsThis chapter includes the following information regarding the removal and replacement of MSAcomponents:•Proceduralover
Verification procedures may include:• Viewing status and error messages sent to the controller LCD panel.• Viewing the LED illumination patterns on the
billing you for the replacement. With a CSR, HP will pay all shipping and part return costs and determinethe courier/carrier to be used.Recommended to
If you do not have any of the suggested equipment for proper grounding, have an Authorized HPReseller install the part.NOTE:For more information on st
Weight warningWARNING!The device can be very heavy. To reduce the risk of personal injury or damage to equipment:• Remove all hot-pluggable power supp
WARNING!Verify that the AC power supply branch circuit that provides power to the rack is not overloaded.Overloading AC power to the rack power supply
CAUTION:To properly ventilate the system, you must provide at least 7.6 centimeters (3.0 inches) of clearance at thefront and back of the device.CAUTI
ComponentHot-pluggable Non- hot-pluggableRedundant power supply moduleXRedundant fan moduleXMSA array controllernl(dual–controller configurations)X*2–P
5. Verify that the Power on/Standby button LED is amber/off and that the fans are off.6. Power off all attached hard drive enclosures.7. Disconnect th
Returningthedefectivecomponent... 32Recommendedtools ... 33Warningsandprecautions ...
Removing or installing a 2-Port Ethernet iSCSI blankBefore you beginCAUTION:• Before removing a component or blank from an operational device, make su
Removing or installing a hard drive blankBefore you beginCAUTION:• Before removing a component or blank from an operational device, make sure that you
Replacing a harddriveBefore you beginCAUTION:• Before removing a component or blank from an operational device, make sure that you have thereplacement
• Donotremoveafailedsecondharddrivefromanarrayuntilthefirst failed or missing hard drivehas been replaced and the rebuild process is complete. (When th
3. Press the ejector button (1) and pull the release lever to the full open position (2).IMPORTANT:Wait approximately 10 seconds for the internal disk
2. Slide the replacement hard drive into the same bay from which the old hard drive was just removed,making sure that the lever is in the full open po
Replacing the controller, controller cache, or controller batteryThe following sections detail procedures for replacing an MSA array controller, contr
Verifying component failureBefore replacing the controller, cache module, or battery pack:• Check the controller LCD display panel for error messages.
• and you are replacing a cache module with another module of the same size, you can remove one ofthe controllers and replace the module on that contr
CAUTION:Do not dispose of batteries, battery packs, and accumulators with general household waste. Use thepublic collection system or return them to H
Installingthepowersupplymodule... 60Verifyingproperoperation ... 60ReplacingtheMSA1510ichassis...
5. Lift the pack upward to unhook the top of the battery pack.6. Wait approximately 15 seconds after removing the old battery to allow the battery cha
6. Verify that the top hook (1)andbottomclip(2) on the battery pack are securely attached to thecache module.15520127. Repeat step 4 through step 6 to
Installing the controller1. Insert the new or serviced array controller into the MSA chassis controller bay (1).2. Push the controller in as far as it
Replacing a 2-Port Ethernet iSCSI moduleBefore you beginCAUTION:• Before removing a component or blank from an operational device, make sure that you
3. Lift the port-colored 2-Port Ethernet iSCSI module latch (1)andpullthemoduleoutoftheenclosure(2).Installing the 2-Port Ethernet iSCSI I/O module1.
Replacing a fanmoduleThe variable-speed fan module is hot-pluggable, so it is not necessary to power down the system toreplace it.Before you beginCAUT
15210Verifying proper operationAfter replacing the fan module, verify that:• The fan starts operating immediately.• The fan Status LED is On.• No new
Replacing a SCSII/OmoduleBefore you beginCAUTION:• Before removing a component or blank from an operational device, make sure that you have thereplace
3. Lift the port-colored SCSI I/O module latch (1)andpulltheSCSII/Omoduleoutofthechassis(2).Installing the SCSI I/O module1. Slide the replacement SCS
Replacing a power supply moduleThe power supply is hot pluggable, so it is not necessary to power down the system to replace it.Before you beginCAUTIO
Latviannotice... 77Lithuaniannotice ... 78Polishnotice ...
Installing the power supply module1. SlidethereplacementpowersupplymoduleintotheMSAchassisbayuntilthemoduleclicksintoplace.2. Connect the AC power cor
Replacing the MSA1510i chassisWhen replacinga chassis, components are removed from the failed chassis and then installed in thereplacement.Components
Removing the chassis componentsPrepareforthereplacement1. Review all warnings, cautions, and preparation procedures as detailed in Warnings and precau
Remove the SCSI I/O modules1. Lift the port-colored latch and pull the module out of the chassis.2. Remove all other SCSI I/O modules or blanks.Remove
2. Grasp the latch handle and pull the controller out of the chassis.3. Remove the other controller or blank.Remove the MSA from the rack1. Remove the
2. Attach the decorative bezel on the front of the MSA by aligning the pins and retaining clips on theback of bezel with the corresponding locations o
Install the SCSI I/O modules1. Slide the module into the chassis SCSI I/O slot until the latch clicks into place.2. Install all other SCSI I/O modules
Install the 2-Port Ethernet iSCSI I/O modules1. Slide the module into the chassis network interconnect slot until the latch clicks into place.NOTE:The
5. Read the controller LCD panel messages during the MSA startup routine.• If the following messages are displayed, the serial number of the original
A Regulatory compliance andsafetyFederal Communications Commission noticePart 15 of the Federal Communications Commission (FCC) Rules and Regulations
About this guideThis guide provides information about:• Maintaining the MSA1510i• Servicing the MSA1510i• Troubleshooting the MSA1510iWARNING!To reduc
For questions regarding your product, contact:Hewlett-Packard CompanyP. O. Box 692000, Mail Stop 530113Houston, Texas 77269-2000Or, call1-800- 652-667
International notices and statementsCanadian notice (Avis Canadien)Class A equipmentThis Class A digital apparatus meets all requirements of the Canad
Japanese noticeKorean notice (A&B)Class A equipmentClass B equipment72Regulatory compliance and safety
SafetyBattery Replacement noticeWARNING!The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkalinebattery pack.
Electrostatic dischargeTo prevent damage to the system, be aware of the precautions you need to follow when setting up thesystem or handling parts. A
místo pro recyklaci elektrických a elektronických zařízení. Okamžité třídění a recyklace odpadu pomůžeuchovat přírodní prostředí a zajistí takový způs
See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi koos teistemajapidamisjäätmetega kõrvaldada. Teie kohus on oma seadmete
Το σύμβολο αυτό στο προϊόν ή τη συσκευασία του υποδεικνύει ότι το συγκεκριμένο προϊόν δενπρέπει να διατίθεται μαζί με τα άλλα οικιακά σας απορρίμματα.
Lithuanian noticeVartotojų iš privačių namųūkiųįrangos atliekų šalinimas Europos SąjungojeŠis simbolis ant gaminio arba jo pakuotėsrodo,kadšiogaminioš
Slovenian noticeOdstranjevanjeodslužene opreme uporabnikov v zasebnih gospodinjstvih v Evropski unijiTa znak na izdelku ali njegovi embalaži pomeni, d
In addition to MSA1510i-specific documents, the following guide, available on the SAN Infrastructurewebsite: http://www.hp.com/go/san, includes detaile
80Regulatory compliance and safety
IndexSymbolsbezelpart numbers,112-Port Ethernet iSCSI moduleLEDs,25part numbers,11replacing,53specifications,14AACcircuit overload, warning,36AC power
electrostatic sensitive partshandling,33packaging,33storing,33transporting,33ESD (electrostatic discharge)precautions,33preventing,33Ffan moduleinstal
MSA1510iillustrated parts breakdown and spare partslist,11powering off and on,38MSA1510ipowering off,20MSA1510i chassisreplacementpreparation,62remova
replacing2–Port Ethernet iSCSI module,53fan module,55hard drive,42best practices,42MSA1510i chassiscomponents,61power supply module,59SCSI I/O module,
TIP:Provides helpful hints and shortcuts.Rack stabilityWARNING!To reduce the risk of personal injury or damage to equipment:• Extend leveling jacks to