
Event notification to system console, e mail, pager, and/or HP Response Centers
Automatic hardware protection of critical environmental problems
Access to management interface and console(s) on LAN failure (modem required)
Remote resetting of hardware partitions
Forward progress indicator (Virtual front panel)
Out of band Manageability and PDC firmware update
Configure manageability and console security
SSL
External Management LAN port: 10/100Base T LAN port using an RJ 45 connector.
One External SCSI ports: Ultra320 LVD SCSI port for connections to mass storage or
media. (A second U320 external port only available when internal drive off of LAN/SCSI is
connected to Smart Array).
Two External 1GbE LAN ports.
Access to internal peripheral bay: The HP Integrity rx7640 Server internal peripheral bay
is located at the top front of the system chassis. The peripheral bay holds up to four low
profile hot plug disks and one half height removable media device ( One half height bay
supports two devices in the case of optional slim line DVD's). Each HP Integrity rx7640
Server core I/O board set contains dual channel Ultra320 SCSI controller chips that
support the SCSI devices in the internal peripheral bay. Each core I/O board set supports
two internal disks. It is important to note that separate controllers and SCSI busses
manage the two disks supported by the primary and secondary core I/O set (This is a
change from the previous architecture in sx1000 based servers). If use of more than two
internal disks is needed, the HP Integrity rx7640 Server will require both core I/O sets.
Core I/O Loading Rules
Minimum of one Core I/O board set (primary) must be purchased with each HP Integrity
rx7640 Server
Load the Primary (1) MP/SCSI board into slot 1 and the LAN SCSI board into I/O cabinet
1 (slot 8).
MP/SCSI slot 0 and I/O cabinet 0 corresponds to Cell Board slot 0. MP/SCSI slot 1 and
I/O cabinet 1 corresponds to Cell Board slot 1.
A cell board must be installed in slot 0 to enable use of Core I/O 0. Likewise, a cell board
must be installed in slot 1 to enable use of Core I/O 1.
Access to two internal disk drives and one half height removable media bay is enabled
with the installation of the first Core I/O board set (Primary).
The optional second Core I/O board set (secondary) must be ordered to enable hardware
partitioning
The optional second Core I/O board set (secondary) must be ordered to enable access to
the third/fourth internal disks
The optional second core I/O board set (secondary) must be ordered to enable using the
optional slim line DVD's.
Internal Disk Drives
HP Integrity rx7640 Server supports up to four internal low profile hot plug disk drives.
Internal Disk Drive Specifications
Product Number
Disk Capacity
Rotational
speed
Average seek time
(read/write)
Sustained
Bandwidth
AD147A
73 GB
15,000 RPM
3.6 msec (read); 3.9 msec (write)
75 MB/s
AD210A
146 GB
15000 RPM
3.6 msec (read); 3.9 msec (write)
75 MB/s
AD265A
300 GB
15000 RPM
3.6 msec (read); 3.9 msec (write)
75 MB/s
HP Integrity rp7410/rp7420/rx7620 disk drives can be carried forward to the HP Integrity rx7640 server.
QuickSpecs
HP Integrity rx7640 Server
Configuration
DA - 12470 Worldwide QuickSpecs — Version 25 — 5/8/2009
Page 17
Comentarios a estos manuales