Updating SWAN Concentrator CLIP Firmware
G06.24 Software Installation and Upgrade Guide528593-005
C-2
Using the SWAN Fast Firmware Update Guided
Procedure (Recommended if Using TSM)
Yellow caution symbols might appear on enclosure icons and on SWANs during the
firmware update. These caution symbols should disappear after you have completed
the SWAN update.
Using the SWAN Fast Firmware Update Guided
Procedure (Recommended if Using TSM)
Follow the instructions in the guided procedure. For online help, open the Help menu
or click Help in any of the procedure’s dialog boxes. Before beginning, see Support
Note S04029.
1. Log on to the TSM Service Application.
2. Do one of the following:
Select Display >SWAN Fast Firmware Update.
Use the Actions dialog box:
a. Right-click the SWAN collection in the tree pane and select Actions from
the shortcut menu.
b. In the Actions dialog box, select the Fast Firmware Update action for the
SWAN collection object.
c. Click Perform action.
The SWAN Fast Firmware Update guided procedure is launched. For example: